In vitro and in vivo comparison of three MR measurement methods for calculating vascular shear stress in the internal carotid artery.

BACKGROUND AND PURPOSE Vascular abnormalities, such as atherosclerosis and the growth and rupture of cerebral aneurysms, result from a derangement in tissue metabolism and injury that are, in part, regulated by hemodynamic stress. The purpose of this study was to establish the feasibility and accuracy of determining wall shear rate in the internal carotid artery from phase-contrast MR data. METHODS Three algorithms were used to generate shear rate estimates from both ungated and cardiac-gated 2D phase-contrast data. These algorithms were linear extrapolation (LE), linear estimation with correction for wall position (LE*), and quadratic extrapolation (QE). In vitro experiments were conducted by using a phantom under conditions of both nonpulsatile and pulsatile flow. The findings from five healthy volunteers were also studied. MR imaging-derived shear rates were compared with values calculated by solving the fluid flow equations. RESULTS Findings of in vitro constant-flow experiments indicated that at one or two excitations, QE has the advantage of good accuracy and low variance. Results of in vitro pulsatile flow experiments showed that neither LE* nor QE differed significantly from the predicted value of wall shear stress, despite errors of 17% and 22%, respectively. In vivo data showed that QE did not differ significantly from the predicted value, whereas LE and LE* did. The percentages of errors for QE, LE, and LE* in vivo measurements were 98.5%, 28.5%, and 36.1%, respectively. The average residual of QE was low because the residuals were both above and below baseline whereas, on average, LE* tended to be a more biased overestimator of the shear rate in volunteers. The average and peak wall shear force in five volunteers was approximately 8.10 dyne/cm2 and 13.2 dyne/cm2, respectively. CONCLUSION Our findings show that LE consistently underestimates the shear rate. Although LE* and QE may be used to estimate shear rate, errors of up to 36% should be expected because of variance above and below the true value for individual measurements.

[1]  D. L. Fry Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients , 1968, Circulation research.

[2]  R. Schroter,et al.  Atheroma and arterial wall shear - Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis , 1971, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[3]  G. Hutchins,et al.  Correlation between intimal thickness and fluid shear in human arteries. , 1981, Atherosclerosis.

[4]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[5]  C. Zarins,et al.  Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress , 1983, Circulation research.

[6]  D. Ku,et al.  Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.

[7]  D J Phillips,et al.  Hemodynamics of the normal human carotid bifurcation: in vitro and in vivo studies. , 1985, Ultrasound in medicine & biology.

[8]  C L Dumoulin,et al.  Three‐dimensional phase contrast angiography , 1989, Magnetic resonance in medicine.

[9]  D D Duncan,et al.  The effect of compliance on wall shear in casts of a human aortic bifurcation. , 1990, Journal of biomechanical engineering.

[10]  L. Brush,et al.  McDonaldʼs Blood Flow in Arteries , 1991 .

[11]  T. Chenevert,et al.  Calculation of pressure gradients from MR velocity data in a laminar flow model. , 1991, Journal of computer assisted tomography.

[12]  D D Duncan,et al.  Effects of arterial compliance and non-Newtonian rheology on correlations between intimal thickness and wall shear. , 1992, Journal of biomechanical engineering.

[13]  B. Rutt,et al.  Frequency response of retrospectively gated phase‐contrast MR imaging: Effect of interpolation , 1993, Journal of magnetic resonance imaging : JMRI.

[14]  P. Stein,et al.  Errors in the estimation of arterial wall shear rates that result from curve fitting of velocity profiles. , 1993, Journal of biomechanics.

[15]  C A Hamilton,et al.  Correction of partial volume inaccuracies in quantitative phase contrast MR angiography. , 1994, Magnetic resonance imaging.

[16]  D B Plewes,et al.  MR measurement of pulsatile pressure gradients , 1994, Journal of magnetic resonance imaging : JMRI.

[17]  Richard M. Leahy,et al.  Determining cardiac velocity fields and intraventricular pressure distribution from a sequence of ultrafast CT cardiac images , 1994, IEEE Trans. Medical Imaging.

[18]  B. L. Langille,et al.  Blood Flow-Induced Remodeling of the Artery Wall , 1995 .

[19]  R. Frayne,et al.  Measurement of fluid‐shear rate by fourier‐encoded velocity imaging , 1995, Magnetic resonance in medicine.

[20]  C M Strother,et al.  Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. , 1995, Neurosurgery.

[21]  V. Orel Mechanochemiemission and atherogenesis. , 1995, Medical hypotheses.

[22]  Richard Frayne,et al.  Accuracy of MR phase contrast velocity measurements for unsteady flow , 1995, Journal of magnetic resonance imaging : JMRI.

[23]  J. Bevan,et al.  Flow-Dependent Regulation of Vascular Function , 1995, Clinical Physiology Series.

[24]  D. A. Christopher,et al.  A wall-less vessel phantom for Doppler ultrasound studies. , 1995, Ultrasound in medicine & biology.

[25]  R. Pettigrew,et al.  Determination of wall shear stress in the aorta with the use of MR phase velocity mapping , 1995, Journal of magnetic resonance imaging : JMRI.

[26]  G J Hademenos,et al.  A biomathematical model of intracranial arteriovenous malformations based on electrical network analysis: theory and hemodynamics. , 1996, Neurosurgery.

[27]  Effects of through‐plane myocardial motion on phase‐difference and complex‐difference measurements of absolute coronary artery flow , 1996, Journal of magnetic resonance imaging : JMRI.

[28]  P Boesiger,et al.  In vivo wall shear stress measured by magnetic resonance velocity mapping in the normal human abdominal aorta. , 1997, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[29]  B. Leupen,et al.  Design and analysis , 1997 .

[30]  D A Steinman,et al.  Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images. , 1997, Journal of biomechanics.

[31]  C. Strother Understanding the natural history of saccular aneurysms. , 1998, AJNR. American journal of neuroradiology.