Behavior of MV Insulators Under Lightning-Induced Overvoltages: Experimental Results and Reproduction of Volt–Time Characteristics by Disruptive Effect Models

This paper presents the results of experimental tests performed with an impulse voltage of short tail (STLI: 1.2/4 ¿s), similar to lightning-induced overvoltages, on composite insulators used in the electric traction lines. The characteristics of volt-time breakdown under STLI waves are shown and compared with the characteristics obtained under standard lightning impulse (LI:1.2/50 ¿s). Models based on the disruptive effect, as proposed by Kind and Chowdhuri, are considered and applied in order to reproduce the volt-time characteristics under standard and nonstandard lightning voltages. The application viability of these models to tested insulators is considered and discussed and the accuracy in their reproduction is evaluated. It is demonstrated that the Kind model, calibrated with a suitable selection of the parameters using standard flashover data (LI), is able to estimate the response of the insulators to the short tail lightning impulses (STLI) with satisfactory accuracy.

[1]  M. Ianoz,et al.  Transient analysis of multiconductor lines above a lossy ground , 1999 .

[2]  A. Porrino,et al.  Performance of Large Air Gaps under Lightning Overvoltages: Experimental Study and Analysis of Accuracy of Predetermination Methods , 1989, IEEE Power Engineering Review.

[3]  A. Carrus An inductance on the Marx generator tail branch-new technique for high efficiency laboratory reproduction of short time to half value lightning impulses , 1989 .

[4]  G. Carrara,et al.  Review of research on nonstandard lightning voltage waves , 1994 .

[5]  R. H. Golde Lightning Surges on Overhead Distribution Lines Caused by Indirect and Direct Lightning Strokes [includes discussion] , 1954, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[6]  Hideki Motoyama,et al.  Experimental study and analysis of breakdown characteristics of long air gaps with short tail lightning impulse , 1996 .

[7]  Ahmed Boubakeur,et al.  Lightning-Induced Voltages on Overhead Power Lines with the Use of the Hybrid Method: Influence of the Shielding Wire , 2010 .

[8]  R. L. Witzke,et al.  Co-ordination of Lightning Arrester Location with Transformer Insulation Level , 1950, Transactions of the American Institute of Electrical Engineers.

[9]  B. W. McConnell,et al.  The effects of nonstandard lightning voltage waveshapes on the impulse strength of short air gaps , 1994 .

[10]  C. Mazzetti,et al.  Short tail lightning impulse behaviour of medium voltage line insulation , 1999 .

[11]  Kunihiko Miyake,et al.  Advanced Observations of Lightning Induced Voltage on Power Distribution Lines (II) , 1986, IEEE Power Engineering Review.

[12]  Mat Darveniza,et al.  Experimental and Analytical Studies of the Effect of Non-Standard Waveshapes on the Impulse Strength of External Insulation , 1973 .

[13]  Kunihiko Miyake,et al.  Advanced Observations of Lightning Induced Voltage on Power Distribution Lines , 1986, IEEE Transactions on Power Delivery.

[14]  Farhad Rachidi,et al.  Lightning-induced voltages on complex distribution systems: models, advanced software tools and experimental validation , 2004 .

[15]  M. Darveniza,et al.  The generalized integration method for predicting impulse volt-time characteristics for non-standard wave shapes-a theoretical basis , 1988 .

[16]  C. Mazzetti,et al.  Optimal selection of disruptive effect models parameters for the reproduction of MV insulators volt-time characteristics under standard and non standard lightning impulses , 2007, 2007 IEEE Lausanne Power Tech.

[17]  Takatoshi Shindo,et al.  A New Calculation Method of Breakdown Voltage-Time Characteristics of Long Air Gaps , 1985, IEEE Transactions on Power Apparatus and Systems.

[18]  F. Muzi,et al.  Lightning induced overvoltages, improvement in quality of service in MV distribution lines by addition of shield wires , 1996 .

[19]  R. L. Witzke,et al.  Surge Protection of Cable-Connected Equipment , 1950, Transactions of the American Institute of Electrical Engineers.

[20]  P. Chowdhuri,et al.  Volt-time characteristics of short air gaps under nonstandard lightning voltage waves , 1997, IEEE Power Engineering Review.