The role of osteogenic index, octahedral shear stress and dilatational stress in the ossification of a fracture callus.

The exact mechanism by which mechanical stimulus regulates the healing process of a bone fracture is not understood. This has led to the development of several hypotheses that predict the pattern of differentiation of tissue during healing that may arise from characteristic fields of stress or strain at the fracture. These have so far remained unproved because data on stress fields in actual fracture tissue have been unavailable until recently. Thus the present study examines the predictive performance of the hypothesis proposed in J Orthop Res 6 (1988) 736, against measured and calculated data reported in J Biomech 33 (2000) 415, using a 2D FEM of a clinical fracture. The hypothesis was used to predict the influence of stress fields present in the Gardner et al. tissues at four temporal stages during healing. These predictions were then correlated with callus-size, rate of endochondral ossification and ossification pattern subsequently observed by Gardner et al. in the clinical fracture. Results corroborate the hypothesis that high octahedral shear stresses may increase the size of the callus during the initial phase of healing, and they also suggest that this may be true during the later stages of the fracture fixation period. However, compressive dilatational stresses were not found to inhibit endochondral ossification, as suggested by the hypothesis. Although high shear stresses were found in regions indicative of fibrous tissue as postulated by the hypothesis, this was not found to be the case for high tensile dilatational stresses. Also, contour diagrams of Osteogenic index (I) indicated only limited correlation with callus maturation and the pattern of healing. Therefore, the hypothesis was not wholly successful in predicting healing pattern.

[1]  T A Einhorn,et al.  The cell and molecular biology of fracture healing. , 1998, Clinical orthopaedics and related research.

[2]  G S Beaupré,et al.  Correlations between mechanical stress history and tissue differentiation in initial fracture healing , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  Nunamaker Dm,et al.  Experimental models of fracture repair. , 1998 .

[4]  J Kenwright,et al.  The influence of induced micromovement upon the healing of experimental tibial fractures. , 1985, The Journal of bone and joint surgery. British volume.

[5]  S Mishra,et al.  Comparative two- and three-dimensional finite element modelling techniques for tibial fractures , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  B. Mckibbin,et al.  The biology of fracture healing in long bones. , 1978, The Journal of bone and joint surgery. British volume.

[7]  A. T. Berman,et al.  The use of the Hickman catheter in orthopaedic infections. Brief note. , 1985, The Journal of bone and joint surgery. American volume.

[8]  L. Claes,et al.  Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. , 1998, Journal of biomechanics.

[9]  J Kenwright,et al.  Controlled mechanical stimulation in the treatment of tibial fractures. , 1989, Clinical orthopaedics and related research.

[10]  J Kenwright,et al.  Mechanical Influences on Tibial Fracture Healing , 1998, Clinical orthopaedics and related research.

[11]  M. Yamagishi,et al.  The biomechanics of fracture healing. , 1955, The Journal of bone and joint surgery. American volume.

[12]  Simon Sevitt,et al.  Bone repair and fracture healing in man , 1980 .

[13]  G S Beaupré,et al.  Role of mechanical loading in the progressive ossification of a fracture callus , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  C Ament,et al.  A fuzzy logic model of fracture healing. , 2000, Journal of biomechanics.

[15]  P S Walker,et al.  Influence of muscle activity on the forces in the femur: an in vivo study. , 1997, Journal of biomechanics.

[16]  A. M. Digioia,et al.  Three-dimensional strain fields in a uniform osteotomy gap. , 1986 .

[17]  D T Davy,et al.  The biomechanical behavior of healing canine radii and ribs. , 1982, Journal of biomechanics.

[18]  T. Gardner,et al.  The biomechanical environment of a bone fracture and its influence upon the morphology of healing. , 2003, Medical engineering & physics.

[19]  F. Duck Physical properties of tissue , 1990 .

[20]  T D Brown,et al.  Some effects of global joint morphology on local stress aberrations near imprecisely reduced intra-articular fractures. , 1990, Journal of biomechanics.

[21]  M Evans,et al.  An instrumented spacial linkage for monitoring relative three-dimensional motion between fracture fragments. , 1996, Journal of biomechanical engineering.

[22]  S M Perren,et al.  Role of interfragmentary strain in fracture healing: Ovine model of a healing osteotomy , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  R. Huiskes,et al.  Finite element analysis of fibrous tissue morphogenesis — A study of the osteogenic index with a biphasic approach , 1996 .

[24]  T N Gardner,et al.  The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study. , 2000, Journal of biomechanics.

[25]  Dennis R. Carter,et al.  Mechanobiology of Skeletal Regeneration , 1998, Clinical orthopaedics and related research.