Integrated microfluidic array plate (iMAP) for cellular and molecular analysis.

Just as the Petri dish has been invaluable to the evolution of biomedical science in the last 100 years, microfluidic cell assay platforms have the potential to change significantly the way modern biology and clinical science are performed. However, an evolutionary process of creating an efficient microfluidic array for many different bioassays is necessary. Specifically for a complete view of a cell response it is essential to incorporate cytotoxic, protein and gene analysis on a single system. Here we present a novel cellular and molecular analysis platform, which allows access to gene expression, protein immunoassay, and cytotoxicity information in parallel. It is realized by an integrated microfluidic array plate (iMAP). The iMAP enables sample processing of cells, perfusion based cell culture, effective perturbation of biologic molecules or drugs, and simultaneous, real-time optical analysis for different bioassays. The key features of the iMAP design are the interface of on-board gravity driven flow, the open access input fluid exchange and the highly efficient sedimentation based cell capture mechanism (∼100% capture rates). The operation of the device is straightforward (tube and pump free) and capable of handling dilute samples (5-cells per experiment), low reagent volumes (50 nL per reaction), and performing single cell protein and gene expression measurements. We believe that the unique low cell number and triple analysis capabilities of the iMAP platform can enable novel dynamic studies of scarce cells.

[1]  K. Mullis,et al.  Specific synthesis of DNA in vitro via a polymerase-catalyzed chain reaction. , 1987, Methods in enzymology.

[2]  Hanry Yu,et al.  A practical guide to microfluidic perfusion culture of adherent mammalian cells. , 2007, Lab on a chip.

[3]  B. Deiman,et al.  Characteristics and applications of nucleic acid sequence-based amplification (NASBA) , 2002, Molecular biotechnology.

[4]  J. Compton,et al.  Nucleic acid sequence-based amplification , 1991, Nature.

[5]  Elisabeth Verpoorte,et al.  Application of surface biopassivated disposable poly(dimethylsiloxane)/glass chips to a heterogeneous competitive human serum immunoglobulin G immunoassay with incorporated internal standard , 2002, Electrophoresis.

[6]  Mengsu Yang,et al.  Dose-dependent cell-based assays in V-shaped microfluidic channels. , 2006, Lab on a chip.

[7]  S. Digumarthy,et al.  Isolation of rare circulating tumour cells in cancer patients by microchip technology , 2007, Nature.

[8]  M. Martin,et al.  Effects of Arsenite on Estrogen Receptor-α Expression and Activity in MCF-7 Breast Cancer Cells. , 2000, Endocrinology.

[9]  Dino Di Carlo,et al.  Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation. , 2003, Lab on a chip.

[10]  P. Lamy,et al.  NASBA: a novel approach to assess hormonal receptors and ERBB2 status in breast cancer , 2006, Clinical chemistry and laboratory medicine.

[11]  Hiroko Tomoyori,et al.  Oxysterol Regulation of Estrogen Receptor α-Mediated Gene Expression in a Transcriptional Activation Assay System Using HeLa Cells , 2004, Bioscience, biotechnology, and biochemistry.

[12]  M. Toner,et al.  Microengineering of cellular interactions. , 2000, Annual review of biomedical engineering.

[13]  A. Folch,et al.  Biomolecular gradients in cell culture systems. , 2008, Lab on a chip.

[14]  Dino Di Carlo,et al.  On-chip cell lysis by local hydroxide generation. , 2005, Lab on a chip.

[15]  A. Khademhosseini,et al.  Rapid generation of spatially and temporally controllable long-range concentration gradients in a microfluidic device. , 2009, Lab on a chip.

[16]  Stephen R. Quake,et al.  Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria , 2006, Science.

[17]  L. Sargent,et al.  Comparison of Established Cell Lines at Different Passages by Karyotype and Comparative Genomic Hybridization , 2004, Bioscience reports.

[18]  A. Manz,et al.  Micro total analysis systems. Latest advancements and trends. , 2006, Analytical chemistry.

[19]  E. Verpoorte Microfluidic chips for clinical and forensic analysis , 2002, Electrophoresis.

[20]  Bryan Lincoln,et al.  Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics. , 2008, Lab on a chip.

[21]  Hsian-Rong Tseng,et al.  Microfluidic image cytometry for quantitative single-cell profiling of human pluripotent stem cells in chemically defined conditions. , 2010, Lab on a chip.

[22]  W. B. Derry,et al.  Mitotic block induced in HeLa cells by low concentrations of paclitaxel (Taxol) results in abnormal mitotic exit and apoptotic cell death. , 1996, Cancer research.

[23]  Luke P. Lee,et al.  Nanoliter scale microbioreactor array for quantitative cell biology , 2006, Biotechnology and bioengineering.

[24]  A. Fire,et al.  Rolling replication of short DNA circles. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[25]  D. Beebe,et al.  Understanding microchannel culture: parameters involved in soluble factor signaling. , 2007, Lab on a chip.

[26]  H. Stevenson,et al.  Molecular and Cellular Determinants of Estrogen Receptor Expression , 2004 .

[27]  G. Walker,et al.  Strand displacement amplification--an isothermal, in vitro DNA amplification technique. , 1992, Nucleic acids research.

[28]  M. Yamada,et al.  Microfluidic particle sorter employing flow splitting and recombining. , 2006, Analytical chemistry.

[29]  Ali Khademhosseini,et al.  Microcirculation within grooved substrates regulates cell positioning and cell docking inside microfluidic channels. , 2008, Lab on a chip.

[30]  D. J. Harrison,et al.  Planar chips technology for miniaturization and integration of separation techniques into monitoring systems. Capillary electrophoresis on a chip , 1992 .

[31]  D. Figeys,et al.  Lab-on-a-chip: a revolution in biological and medical sciences , 2000, Analytical chemistry.

[32]  Chunsun Zhang,et al.  PCR microfluidic devices for DNA amplification. , 2006, Biotechnology advances.

[33]  David J Beebe,et al.  From the cellular perspective: exploring differences in the cellular baseline in macroscale and microfluidic cultures. , 2009, Integrative biology : quantitative biosciences from nano to macro.

[34]  O. Orwar,et al.  Microfluidic gradient-generating device for pharmacological profiling. , 2005, Analytical chemistry.

[35]  Nancy L Allbritton,et al.  CRITICAL REVIEW www.rsc.org/loc | Lab on a Chip Analysis of single mammalian cells on-chip , 2006 .

[36]  Jong Wook Hong,et al.  Integrated nanoliter systems , 2003, Nature Biotechnology.

[37]  S. Jacobson,et al.  Integrated system for rapid PCR-based DNA analysis in microfluidic devices. , 2000, Analytical chemistry.

[38]  B. Chung,et al.  Human neural stem cell growth and differentiation in a gradient-generating microfluidic device. , 2005, Lab on a chip.

[39]  Helene Andersson-Svahn,et al.  PCR amplification and genetic analysis in a microwell cell culturing chip. , 2009, Lab on a chip.

[40]  G. Hospers,et al.  Endothelium in vitro: A review of human vascular endothelial cell lines for blood vessel-related research , 2004, Angiogenesis.

[41]  G. Woloschak,et al.  Effect of passage number on cellular response to DNA-damaging agents: cell survival and gene expression. , 1997, Cancer letters.

[42]  R A Mathies,et al.  High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[43]  Soichi Yabuki,et al.  Microbioassay system for an anti-cancer agent test using animal cells on a microfluidic gradient mixer. , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.