Influence of the design of the prosthesis on the outcome after hemiarthroplasty of the shoulder in displaced fractures of the head of the humerus.

We reviewed 39 patients with displaced three- and four-part fractures of the humerus. In 21 patients (group A) we had used an anatomical prosthesis for the humeral head and in 18 (group B) an implant designed for fractures. When followed up at a mean of 29.3 months after surgery the overall Constant score was 51.9 points; in group A it was 51.5 and in group B 52.4 points. The subjective satisfaction of the patients was assessed using a numerical rating scale and was similar in both groups. In group A complete healing of the tuberosities was found in 29% and 50% in group B. Partial integration was seen in 29% of group A and in only one patient in group B, while resorption was noted in 43% of group A and 44% of group B. The functional outcome was significantly better in patients with complete or partial healing of the tuberosities (p=0.022). The specific trauma prosthesis did not lead to better healing of the tuberosities. The difference in clinical outcome obtained by the two designs did not reach statistical significance.

[1]  L. Bigliani,et al.  Arthroplasty and acute shoulder trauma. Reasons for success and failure. , 1994, Clinical orthopaedics and related research.

[2]  R. Hawkins,et al.  Acute prosthetic replacement for severe fractures of the proximal humerus. , 1993, Clinical orthopaedics and related research.

[3]  C. Court-Brown,et al.  Primary Hemiarthroplasty for Treatment of Proximal Humeral Fractures , 2003, The Journal of bone and joint surgery. American volume.

[4]  E. Lambiris,et al.  Hemiarthroplasty in the Treatment of Comminuted Intraarticular Fractures of the Proximal Humerus , 1997, Clinical orthopaedics and related research.

[5]  Douglas G. Altman,et al.  Practical statistics for medical research , 1990 .

[6]  C. Constant,et al.  A clinical method of functional assessment of the shoulder. , 1987, Clinical orthopaedics and related research.

[7]  H. Tscherne,et al.  [Hemi-arthroplasty--primary or secondary measure for 3- and 4-fragment fractures of the proximal humerus in the elderly?]. , 1996, Der Unfallchirurg.

[8]  C. Neer Displaced proximal humeral fractures , 2007 .

[9]  J. Zuckerman,et al.  Functional outcome after humeral head replacement for acute three- and four-part proximal humeral fractures. , 1995, Journal of shoulder and elbow surgery.

[10]  Levent Eralp,et al.  Prognostic factors in prosthetic replacement for acute proximal humerus fractures. , 2003, Journal of orthopaedic trauma.

[11]  Mark A Mighell,et al.  Outcomes of hemiarthroplasty for fractures of the proximal humerus. , 2003, Journal of shoulder and elbow surgery.

[12]  H. Tscherne,et al.  Die Hemiarthroplastik – Primär- oder Sekundärmaßnahme für 3- und 4-Fragment-Frakturen des proximalen Humerus beim älteren Menschen? , 1996, Der Unfallchirurg.

[13]  T. Movin,et al.  Poor function after shoulder replacement in fracture patients. A retrospective evaluation of 29 patients followed for 2-12 years. , 1998, Acta orthopaedica Scandinavica.

[14]  R. Warren,et al.  Modular hemiarthroplasty for fractures of the proximal part of the humerus. , 1992, The Journal of bone and joint surgery. American volume.

[15]  D P Greenwald,et al.  Biomechanical effects of malposition of tuberosity fragments on the humeral prosthetic reconstruction for four-part proximal humerus fractures. , 2001, Journal of shoulder and elbow surgery.

[16]  S W O'Driscoll,et al.  Radiographic assessment of cemented humeral components in shoulder arthroplasty. , 2001, Journal of shoulder and elbow surgery.

[17]  H. A. Karladani Treatment of displaced proximal humeral fractures in elderly patients. , 1999, The Journal of bone and joint surgery. British volume.

[18]  W. Menth-Chiari,et al.  Outcome after primary hemiarthroplasty for fracture of the head of the humerus. A retrospective multicentre study of 167 patients. , 2004, The Journal of bone and joint surgery. British volume.

[19]  R. Cofield Comminuted Fractures of the Proximal Humerus , 1988, Clinical orthopaedics and related research.

[20]  P Boileau,et al.  Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. , 2002, Journal of shoulder and elbow surgery.