Abstract The Indian Test Facility (INTF) vacuum vessel is designed to install a full-scale test set-up of Diagnostic Neutral Beam (DNB) [1] for the qualification of beam parameters and the behavior of beam-line components prior to installation and operation in ITER. Vacuum vessel is designed in cylindrical shape having length of ∼9 m with diameter of ∼4.5 m and has a detachable top-lid for mounting as well as removal of internal components during installation and maintenance phases. The Vessel has hemispherical dish-ends with large openings for high-voltage bushing on one side and duct on another side. Vessel is provided with openings for hydraulic, cryo, gas-feed and diagnostics. Vessel duct is composed of three segments with length ranges from 3 m to 5 m with diameter of ∼1.5 m and one vessel at the end to house the second calorimeter. The objective of this paper is to present the design and analysis of vacuum vessel, with respect to its functional and operational requirements. The design calculations are done as per ASME-BPVC SectionVIII-Div.1 and subsequently Finite Element Analysis (FEM) method has been adopted to verify the design.