Comparison of a silicon carbide-coated stent versus a noncoated stent in human beings: the Tenax versus Nir Stent Study's long-term outcome.

BACKGROUND Stents coated with amorphous hypothrombogenic silicon carbide (a-SiC:H) have low restenosis rates in humans. Recurrence in a-SiC:H at mid-term follow-up has been shown to be similar to a stainless steel device. The long-term outcome, however, may be different. METHODS Four hundred ninety-seven patients (63.4 +/- 9.8 years of age) received either the a-SiC:H-coated Tenax stent (Biotronik, Berlin, Germany) or the 316L Nir stent (Boston Scientific, Maple Grove, Minn). Lesions had to be covered with one stent only (diameter > or =2.8 mm, length <20 mm). Exclusion criteria comprised acute myocardial infarction and angiographic thrombus within the target vessel. Twenty-five of 497 (5%) patients were excluded for protocol violation. Clinical follow-up was completed in 450 of 472 (95.3%) and angiographic follow-up was completed in 365 of 472 (77.3%); 22 of 472 (4.7%) patients were lost to follow-up. RESULTS Major adverse coronary events occurred in 28 of 233 (12%) of the Tenax recipients and in 31 of 217 (14.3%) of the Nir recipients (P =.50). Acute myocardial infarctions were less frequent in the Tenax recipients after > or =60 weeks. Premature target lesion revascularization was performed in 16 of 233 (6.9%) patients in the Tenax group and 11 of 217 (5.1%) (P =.54) patients in the Nir group. Coronary bypass operations were similar after Tenax or Nir stent deployment (3/233 [1.3%] vs 6/217 [2.8%], P =.43), as were deaths in 7 of 233 (3%) versus 8 of 217 (3.7%) (P =.88), respectively. CONCLUSIONS Both stents had a low rate of major adverse coronary events at 81 +/- 12 weeks of follow-up, with no definite superiority of any of the devices.

[1]  F. Fernández‐Avilés,et al.  Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START): a four-year follow-up. , 1999, Journal of the American College of Cardiology.

[2]  A. Bolz,et al.  Development of a New Hybrid Coronary Stent Design with Optimized Biocompatible Properties , 2000 .

[3]  S. Ellis,et al.  Relation of operator volume and experience to procedural outcome of percutaneous coronary revascularization at hospitals with high interventional volumes. , 1997, Circulation.

[4]  C. Di Mario,et al.  Angiographic and clinical outcome following coronary stenting of small vessels: a comparison with coronary stenting of large vessels. , 1998, Journal of the American College of Cardiology.

[5]  P. Teirstein,et al.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. , 1994, The New England journal of medicine.

[6]  A. Baumbach,et al.  Local paclitaxel delivery for the prevention of restenosis: biological effects and efficacy in vivo. , 2000, Journal of the American College of Cardiology.

[7]  A. Kastrati,et al.  Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease. , 2000, Circulation.

[8]  K Ulm,et al.  Restenosis after coronary placement of various stent types. , 2001, The American journal of cardiology.

[9]  D. Antoniucci,et al.  Clinical and angiographic outcome after coronary arterial stenting with the carbostent. , 2000, The American journal of cardiology.

[10]  R E Vlietstra,et al.  Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. , 1992, Journal of the American College of Cardiology.

[11]  E. Edelman,et al.  Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury. , 1999, Circulation research.

[12]  A. Castaigne,et al.  Effect of pravastatin on angiographic restenosis after coronary balloon angioplasty. The PREDICT Trial Investigators. Prevention of Restenosis by Elisor after Transluminal Coronary Angioplasty. , 1997, Journal of the American College of Cardiology.

[13]  W. J. van der Giessen,et al.  Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. , 1998, Journal of the American College of Cardiology.

[14]  E. Hannan,et al.  Reduction in angioplasty complications after the introduction of coronary stents: results from a consecutive series of 2242 patients. , 1996, American heart journal.

[15]  Antonio Colombo,et al.  Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II) , 1998, The Lancet.

[16]  K. Endresen,et al.  Stenting in Chronic Coronary Occlusion (SICCO): a randomized, controlled trial of adding stent implantation after successful angioplasty. , 1996, Journal of the American College of Cardiology.

[17]  E. DeLong,et al.  Relationship between physician and hospital coronary angioplasty volume and outcome in elderly patients. , 1997, Circulation.

[18]  Comparison of slotted tube versus coil stent implantation for ostial left anterior descending coronary artery stenosis: initial and late clinical outcomes. , 1998 .

[19]  W Rutsch,et al.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.