Blood pressure measuring methods.

Blood pressure can be measured directly or indirectly. While direct methods provide the maximum quantity of reliable information from probes inserted into the blood stream, indirect methods produce much less disturbance to the subject. Indirect methods are based on the adjustment of a known external pressure to equal the vascular pressure. Systolic and diastolic pressure can be determined intermittently from the pressure that will just collapse the vessel; an approximation of the instantaneous pressure level is obtained from a surrounding chamber adjusted to remove all vessel wall tension. Direct methods can provide continuous, high fidelity recordings of the absolute vascular pressure via a catheter either to transmit the blood pressure through liquid to an external sensor or to carry the signal leads from a miniature internal sensor. External sensors require careful adjustment of the catheter dimensions to obtain optimum dynamic response. Internal sensors provide the maximum dynamic response and avoid acceleration artifacts. Convenience of electrical signal manipulation, display and recording have made electrical transducers increasingly popular.

[1]  J. Dávila,et al.  Combined catheterization of the heart utilizing a modified transbronchial technique, percutaneous left ventricular puncture, and venous and arterial catheterization. , 1959, American heart journal.

[2]  Frank W. Noble The Sonic Valve Pressure Gauge , 1957 .

[3]  H. V. Rice,et al.  A practical method for the measurement of systolic blood pressures of infants. , 1959, Pediatrics.

[4]  A. Kolin,et al.  Electro-Magnetic Measurement of Blood Flow and Sphygmomanometry in the Intact Animal , 1941 .

[5]  E. J. Ellis,et al.  An Intracardiac Manometer: Its Evaluation and Application , 1951, Circulation.

[6]  W. Hamilton,et al.  Recommendations for Human Blood Pressure Determinations by Sphygmomanometers , 1951, Circulation.

[7]  J. Lilly The Electrical Capacitance Diaphragm Manometer , 1942 .

[8]  Manning,et al.  A Comparison of Direct and Indirect Blood‐Pressure Determinations , 1953, Circulation.

[9]  G. Neligan,et al.  Sphygmomanometer for the newborn. , 1959, Lancet.

[10]  H. Warner,et al.  A Study of the Mechanism of Pressure Wave Distortion by Arterial Walls Using an Electrical Analog , 1957, Circulation research.

[11]  Eastwood Dw Use of a photo-sphygmometer in indirect blood pressure measurements. , 1959 .

[12]  A. Heyman,et al.  Determination of Retinal Artery Pressures in Diagnosis of Carotid Artery Occlusion , 1957, Neurology.

[13]  A PHOTOELECTRIC MEMBRANE MANOMETER. , 1942, Science.

[14]  A. T. Hansen,et al.  Pressure measurement in the human organism , 1949 .

[15]  D. L. Fry,et al.  Physiologic recording by modern instruments with particular reference to pressure recording. , 1960, Physiological reviews.

[16]  S. Aronow,et al.  An automatic blood-pressure-recording machine. , 1957, The New England journal of medicine.

[17]  Intracardiac Catheter Tip Piezoresistive Pressure Gauge , 1960 .

[18]  J. Weinman,et al.  Application of a photoconductive cell to the study of peripheral circulation in limbs of animals and man. , 1960, Journal of applied physiology.

[19]  C. Englund,et al.  A mechano-electronic transducer blood pressure recorder. , 1959, Acta physiologica Scandinavica. Supplementum.

[20]  Leon Brotmacher Evaluation of Derivation of Cardiac Output from Blood Pressure Measurements , 1957, Circulation research.

[21]  D. L. Fry,et al.  An Electric Device for Instantaneous and Continuous Computation of Aortic Blood Velocity , 1957, Circulation research.

[22]  O. Gauer,et al.  A miniature pressure-recording device. , 1950, Science.

[23]  C. Noback,et al.  Volume elasticity characteristics of the human aorta and prediction of the stroke volume from the pressure pulse. , 1948, The American journal of physiology.