Tremor suppression in ECG

BackgroundElectrocardiogram recordings are very often contaminated by high-frequency noise usually power-line interference and EMG disturbances (tremor). Specific method for interference cancellation without affecting the proper ECG components, called subtraction procedure, was developed some two decades ago. Filtering out the tremor remains a priori partially successful since it has a relatively wide spectrum, which overlaps the useful ECG frequency band.MethodThe proposed method for tremor suppression implements the following three procedures. Contaminated ECG signals are subjected to moving averaging (comb filter with linear phase characteristic) with first zero set at 50 Hz to suppress tremor and PL interference simultaneously. The reduced peaks of QRS complexes and other relatively high and steep ECG waves are then restored by an introduced by us procedure called linearly-angular, so that the useful high frequency components are preserved in the range specified by the embedded in the ECG instrument filter, usually up to 125 Hz. Finally, a Savitzky-Golay smoothing filter is applied for supplementary tremor suppression outside the QRS complexes.ResultsThe results obtained show a low level of the residual EMG disturbances together with negligible distortion of the wave shapes regardless of rhythm and morphology changes.

[1]  Pablo Laguna,et al.  Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals , 2000, IEEE Transactions on Biomedical Engineering.

[2]  K. Egiazarian,et al.  Suppression of electromyogram interference on the electrocardiogram by transform domain denoising , 2001, Medical and Biological Engineering and Computing.

[3]  Alireza K. Ziarani,et al.  A nonlinear adaptive method of elimination of power line interference in ECG signals , 2002, IEEE Transactions on Biomedical Engineering.

[4]  Atanas P. Gotchev,et al.  ECG signal denoising using wavelet domain wiener filtering , 2000, 2000 10th European Signal Processing Conference.

[5]  Ali H. Shoeb,et al.  Model-based filtering, compression and classification of the ECG , 2005 .

[6]  Ivan Dotsinsky,et al.  Power-line interference subtraction from the electrocardiogram in the presence of electromyogram artifacts , 2002 .

[7]  P. Caminal,et al.  Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques , 1992, IEEE Transactions on Biomedical Engineering.

[8]  I Dotsinsky,et al.  Optimization of bi-directional digital filtering for drift suppression in electrocardiogram signals , 2004, Journal of medical engineering & technology.

[9]  P. A. Lynn Online digital filters for biological signals: some fast designs for a small computer , 1977, Medical and Biological Engineering and Computing.

[10]  Karen O. Egiazarian,et al.  Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method , 2002, 2002 IEEE International Conference on Acoustics, Speech, and Signal Processing.

[11]  J G Webster,et al.  60-HZ interference in electrocardiography. , 1973, IEEE transactions on bio-medical engineering.

[12]  Marian Kotas,et al.  Projective filtering of time-aligned ECG beats , 2004, IEEE Transactions on Biomedical Engineering.

[13]  C. A. Grimbergen,et al.  HIGH QUALITY RECORDING OF BIOELECTRIC EVENTS . I : INTERFERENCE REDUCTION , THEORY AND PRACTICE , 2009 .

[14]  I. Christov,et al.  Filtering of electromyogram artifacts from the electrocardiogram. , 1999, Medical engineering & physics.

[15]  I I Christov Dynamic powerline interference subtraction from biosignals , 2000, Journal of medical engineering & technology.

[16]  J. Jossinet,et al.  Nonlinear transient response of electrode—electrolyte interfaces , 1998, Medical and Biological Engineering and Computing.

[17]  P. Caminal,et al.  Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance , 1991, IEEE Transactions on Biomedical Engineering.

[18]  Shen Luo,et al.  Experimental study: brachial motion artifact reduction in the ECG , 1995, Computers in Cardiology 1995.

[19]  J J Bailey,et al.  Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter. , 1989, Journal of electrocardiology.

[20]  Chavdar Levkov,et al.  Removal of power-line interference from the ECG: a review of the subtraction procedure , 2005, Biomedical engineering online.

[21]  Mihai Romanca,et al.  Electrocardiogram Pre-Processing, For The Removal Of High Frequency And Power Line Frequency Noise , 1998, Proceedings of the 6th International Conference on Optimization of Electrical and Electronic Equipments.

[22]  Ju-Won Lee,et al.  Design of an Adaptive Filter with a Dynamic Structure for ECG Signal Processing , 2005 .

[23]  K. Raoof,et al.  Multidimensional adaptive method for cancelling EMG signal from the ECG signal , 1995, Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society.

[24]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[25]  N.V. Thakor,et al.  Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection , 1991, IEEE Transactions on Biomedical Engineering.

[26]  J J Bailey,et al.  A filter to suppress ECG baseline wander and preserve ST-segment accuracy in a real-time environment. , 1991, Journal of electrocardiology.

[27]  J. S. Sahambi,et al.  Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets , 1997, Medical and Biological Engineering and Computing.

[28]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.