Poly(L-lactide) implants for repair of human orbital floor defects: clinical and magnetic resonance imaging evaluation of long-term results.

PURPOSE The purpose of this study was to evaluate the long-term outcome of repair of orbital floor defects in patients with resorbable as-polymerized poly(L-lactide) (PLLA) implants and to determine whether these patients showed symptoms that could be indicative of the presence of a late tissue response. PATIENTS AND METHODS Six patients (four women, two men; mean age, 39 years; range, 18 to 67 years) treated with PLLA implants for orbital floor fractures were recalled for follow-up examination after a period ranging from 3 1/2 to 6 1/2 years. The examination consisted of an interview and a physical examination, including an ophthalmologic and orthoptic consultation. For evaluation of the orbital tissues, coronal spin echo T1- and T2-weighted magnetic resonance images (MRIs) were made through both orbits. RESULTS None of the patients reported any problems in the years preceding the follow-up examination that might have indicated complications. Clinical examination of the operative sites revealed no abnormalities. At ophthalmologic and orthoptic consultation, normal eye function, without diplopia or restriction of motility, was found in all patients. The MRIs showed no indication of an abnormal or increased soft tissue reaction in the orbital region. CONCLUSIONS Based on the results of this study, it can be concluded that PLLA orbital floor implants have the potential for successful use in repair of human orbital floor defects.

[1]  L. P. Yasenchak,et al.  Tissue response to implanted polymers: the significance of sample shape. , 1976, Journal of biomedical materials research.

[2]  R. Bos,et al.  Degradation of and tissue reaction to biodegradable poly(L-lactide) for use as internal fixation of fractures: a study in rats. , 1991, Biomaterials.

[3]  O. Böstman,et al.  Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. , 1990, The Journal of bone and joint surgery. British volume.

[4]  O. Böstman,et al.  Polymeric debris from absorbable polyglycolide screws and pins. Intraosseous migration studied in rabbits. , 1992, Acta orthopaedica Scandinavica.

[5]  A. Pennings,et al.  Bio-absorbable plates and screws for internal fixation of mandibular fractures. A study in six dogs. , 1989, International journal of oral and maxillofacial surgery.

[6]  A. Pennings,et al.  Poly(L-lactide) implants in repair of defects of the orbital floor: an animal study. , 1990, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[7]  C. Lindqvist,et al.  Reconstruction of orbital floor with polydioxanone plate. , 1991, International journal of oral and maxillofacial surgery.

[8]  H. Curtin,et al.  Head and Neck Imaging , 1988 .

[9]  W. Morain,et al.  Reconstruction of Orbital Wall Fenestrations with Polyglactin 910 Film , 1987, Plastic and reconstructive surgery.

[10]  R. Cucin,et al.  Extrusion of an infected orbital-floor prosthesis after 15 years. , 1981, Plastic and reconstructive surgery.

[11]  Geert Boering,et al.  POLY(L-LACTIC)ACID IMPLANTS IN REPAIR OF DEFECTS OF THE ORBITAL FLOOR - A 5-YEAR ANIMAL STUDY , 1994 .

[12]  P. Manson,et al.  Use of Medpor porous polyethylene implants in 140 patients with facial fractures. , 1993, The Journal of craniofacial surgery.

[13]  R. Mathog,et al.  Orbital wall and volume relationships. , 1988, Archives of otolaryngology--head & neck surgery.

[14]  W C de Bruijn,et al.  Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. , 1993, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[15]  P. Manson,et al.  Management of blow-out fractures of the orbital floor. II. Early repair for selected injuries. , 1991, Survey of ophthalmology.

[16]  S. R. Taylor,et al.  Effect of surface texture on the soft tissue response to polymer implants. , 1983, Journal of biomedical materials research.

[17]  Dutton Jj Management of blow-out fractures of the orbital floor. , 1991 .

[18]  A. Pennings,et al.  Bone-plates and screws of bioabsorbable poly (L-lactide)--an animal pilot study. , 1989, The British journal of oral & maxillofacial surgery.

[19]  G. Boering,et al.  Material properties and tissue reaction during degradation of poly (96L/4D-lactide)-a study in vitro and in rats , 1995 .

[20]  G. Boering,et al.  Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures. , 1987, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[21]  J. Mauriello,et al.  Dacryocystitis. Late complication of orbital floor fracture repair with implant. , 1987, Ophthalmology.

[22]  P. Manson,et al.  Studies on Enophthalmos: II. The Measurement of Orbital Injuries and Their Treatment by Quantitative Computed Tomography , 1986, Plastic and reconstructive surgery.

[23]  Albert J. Pennings,et al.  SYNTHESIS OF HIGH-MOLECULAR-WEIGHT POLY(L-LACTIDE) INITIATED WITH TIN 2-ETHYLHEXANOATE , 1987 .

[24]  S A Burres,et al.  Repair of orbital blowout fractures with marlex mesh and gelfilm , 1981, The Laryngoscope.

[25]  W. Dougherty,et al.  The natural history of alloplastic implants in orbital floor reconstruction: an animal model. , 1994, The Journal of craniofacial surgery.