Experimental evaluation of a robust optimization method for IMRT of moving targets.

Internal organ motion during radiation therapy, if not considered appropriately in the planning process, has been shown to reduce target coverage and increase the dose to healthy tissues. Standard planning approaches, which use safety margins to handle intrafractional movement of the tumor, are typically designed based on the maximum amplitude of motion, and are often overly conservative. Comparable coverage and reduced dose to healthy organs appear achievable with robust motion-adaptive treatment planning, which considers the expected probability distribution of the average target position and the uncertainty of its realization during treatment delivery. A dosimetric test of a robust optimization method for IMRT was performed, using patient breathing data. External marker motion data acquired from respiratory-gated radiotherapy patients were used to build and test the framework for robust optimization. The motion trajectories recorded during radiation treatment itself are not strictly necessary to generate the initial version of a robust treatment plan, but can be used to adapt the plan during the course of treatment. Single-field IMRT plans were optimized to deliver a uniform dose to a rectangular area. During delivery on a linear accelerator, a computer-driven motion phantom reproduced the patients' breathing patterns and a two-dimensional ionization detector array measured the dose delivered. The dose distributions from robust-optimized plans were compared to those from standard plans, which used a margin expansion. Dosimetric tests confirmed the improved sparing of the non-target area with robust planning, which was achieved without compromising the target coverage. The maximum dose in robust plans did not exceed 110% of the prescription, while the minimum target doses were comparable in standard and robust plans. In test courses, optimized for a simplified target geometry, and delivered to a phantom that moved in one dimension with an average amplitude of 17 mm, the robust treatment design produced a reduction of more than 12% of the integral dose to non-target areas, compared to the standard plan using 10 mm margin expansion.

[1]  Steve B. Jiang,et al.  Temporo-spatial IMRT optimization: concepts, implementation and initial results , 2005, Physics in medicine and biology.

[2]  Cedric X. Yu,et al.  Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study , 2005, Physics in medicine and biology.

[3]  Steve Webb,et al.  Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: an experimental study. , 2008, Medical physics.

[4]  Jan-Jakob Sonke,et al.  Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. , 2008, International journal of radiation oncology, biology, physics.

[5]  Steve B. Jiang,et al.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates , 2005, Physics in medicine and biology.

[6]  Gregory C Sharp,et al.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets. , 2008, Medical physics.

[7]  S Webb,et al.  A new way of adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion , 2008, Physics in medicine and biology.

[8]  John N. Tsitsiklis,et al.  Robust Management of Motion Uncertainty in Intensity-Modulated Radiation Therapy , 2008, Oper. Res..

[9]  G. Benchetrit Breathing pattern in humans: diversity and individuality. , 2000, Respiration physiology.

[10]  Stephen J. Wright,et al.  Efficient schemes for robust IMRT treatment planning , 2006, Physics in medicine and biology.

[11]  Lei Xing,et al.  Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework , 2007, Physics in medicine and biology.

[12]  Steve B Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. , 2003, Physics in medicine and biology.

[13]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[14]  U Oelfke,et al.  Worst case optimization: a method to account for uncertainties in the optimization of intensity modulated proton therapy , 2008, Physics in medicine and biology.

[15]  Margrit Betke,et al.  The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. , 2003, International journal of radiation oncology, biology, physics.

[16]  J. Unkelbach,et al.  Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions. , 2004, Physics in medicine and biology.

[17]  R. Emery,et al.  Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques. , 2004, International journal of radiation oncology, biology, physics.

[18]  S. Henderson,et al.  Robust optimization for intensity modulated radiation therapy treatment planning under uncertainty , 2005, Physics in medicine and biology.

[19]  Di Yan,et al.  Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: a reproducibility study with breast cancer patients. , 2003, International journal of radiation oncology, biology, physics.

[20]  S Cora,et al.  Use of motion tracking in stereotactic body radiotherapy: Evaluation of uncertainty in off-target dose distribution and optimization strategies , 2006, Acta oncologica.

[21]  Marnix G Witte,et al.  IMRT optimization including random and systematic geometric errors based on the expectation of TCP and NTCP. , 2007, Medical physics.

[22]  John N Tsitsiklis,et al.  A robust approach to IMRT optimization , 2006, Physics in medicine and biology.

[23]  Radhe Mohan,et al.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. , 2005, Medical physics.

[24]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.