Evaluation of positron-emission-tomography for visualisation of migration processes in geomaterials

Abstract Positron-emission-tomography (PET) was applied for direct visualisation of solute transport in order to overcome the limitations of conventional methods for measuring advection and diffusion properties. At intervals from minutes to days the 3D-spatial distribution of the PET-tracer is determined. This spatiotemporal evolution of the tracer concentration can be used as experimental basis for clarification of the relevant transport processes, derivation of transport parameters, and model calibration. Here, 18 F and 124 I in 0.01 M carrier solution of KF and KI, respectively, have been chosen out of the limited number of available PET-tracers, primarily on account of their decay time and the time span of the experiments. The sample is a granite core from the Aspo Hard Rock Laboratory which carries an axial fracture with an aperture of ∼0.5 mm. Therefore, its permeability is high: high injection rates of 0.1 ml/min caused a pressure drop below 100 kPa. The experiments showed that the transport path through the fracture is modulated by the flow rate. The comparison of the experiments with different flow rates indicates diffusion into the matrix material at localized sites. However, the derived diffusion length falls below the resolution limits of the medical PET-scanner. With recently available dedicated high-resolution PET-scanners, which are usually applied in biomedical research, diffusion effects will be clearly resolvable.

[1]  E. Hoffman,et al.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. , 1999, Physics in medicine and biology.

[2]  Andrew Binley,et al.  Electrical resistance tomography. , 2000 .

[3]  P. Jacobs,et al.  Applications of X-ray computed tomography in the geosciences , 2003, Geological Society, London, Special Publications.

[4]  R. P. Maguire,et al.  Positron emission tomography of large rock samples using a multiring PET instrument , 1997 .

[5]  J. Tellam,et al.  Non-reactive solute movement through saturated laboratory samples of undisturbed stratified sandstone , 2006, Geological Society, London, Special Publications.

[6]  U. Pietrzyk,et al.  Flow visualization in porous media via Positron Emission Tomography , 1998 .

[7]  Dominique Sappey-Marinier,et al.  Raytest ClearPET™, a new generation small animal PET scanner , 2007 .

[8]  Chen,et al.  Simulation of multicomponent fluids in complex three-dimensional geometries by the lattice Boltzmann method. , 1996, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[9]  Osama Sabri,et al.  Tomographic radiotracer studies of the spatial distribution of heterogeneous geochemical transport processes , 2007 .

[10]  P. Fowles,et al.  Industrial positron-based imaging: Principles and applications , 1994 .

[11]  Simon R. Cherry,et al.  PET: Physics, Instrumentation, and Scanners , 2006 .

[12]  D. Parker,et al.  Investigation of the Geometrical Dispersion Regime in a Single Fracture Using Positron Emission Projection Imaging , 2004 .

[13]  William A. Edelstein,et al.  NMR Imaging for Core Analysis , 1988 .

[14]  David W. Townsend,et al.  Porosity and pathway determination in crystalline rock by positron emission tomography and neutron radiography , 1996 .

[15]  Osama Sabri,et al.  Positron emission tomography for modelling of geochemical transport processes in clay , 2005 .