Continuous measurement of accommodation in human factor applications
暂无分享,去创建一个
[1] ALIZA M THOMPSON,et al. Accuracy and Precision of the Tomey ViVA Infrared Photorefractor , 1996, Optometry and vision science : official publication of the American Academy of Optometry.
[2] Nobuyuki Hiruma,et al. Characteristics of accommodation toward apparent depth , 1999, Vision Research.
[3] O J Braddick,et al. Eccentric Photorefraction: Optical Analysis and Empirical Measures , 1985, American journal of optometry and physiological optics.
[4] J S Wolffsohn,et al. Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[5] M Millodot,et al. Clinical evaluation of the Canon Autoref R-1. , 1985, American journal of optometry and physiological optics.
[6] J Wattam-Bell,et al. Measurement of Astigmatism by Automated Infrared Photoretinoscopy , 1997, Optometry and vision science : official publication of the American Academy of Optometry.
[7] J S Wolffsohn,et al. Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[8] H C Howland,et al. Laboratory, Clinical, and Kindergarten Test of a New Eccentric Infrared Photorefractor (PowerRefractor) , 2000, Optometry and vision science : official publication of the American Academy of Optometry.
[9] B Davis,et al. Calibration of the Canon Autoref R‐1 for continuous measurement of accommodation , 1993, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[10] J. Sparrow,et al. Screening for refractive errors with the Topcon PR2000 Pediatric Refractometer. , 2000, Investigative ophthalmology & visual science.
[11] G WESTHEIMER,et al. Factors influencing accommodation responses of the human eye. , 1959, Journal of the Optical Society of America.
[12] B. Gilmartin,et al. The effect of pupil size on static and dynamic measurements of accommodation using an infra‐red optometer , 1989, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[13] H D Crane,et al. Servo-controlled infrared optometer. , 1970, Journal of the Optical Society of America.
[14] H. D. Crane,et al. Accurate three-dimensional eyetracker. , 1978, Applied optics.
[15] S. Chat,et al. Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[16] W Wesemann,et al. Theory of eccentric photorefraction (photoretinoscopy): astigmatic eyes. , 1991, Journal of the Optical Society of America. A, Optics and image science.
[17] B Winn,et al. Binocular accommodation reaction and response times for normal observers , 1989, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[18] J R Pugh,et al. Modification of the Canon Auto Ref R1 for use as a continuously recording infra‐red optometer , 1988, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[19] H C Howland,et al. Optics of Photoretinoscopy: Results from Ray Tracing , 1985, American journal of optometry and physiological optics.
[20] O J Braddick,et al. Screening for refractive errors in 6-9 month old infants by photorefraction. , 1984, The British journal of ophthalmology.
[21] F. Schaeffel,et al. Inter‐individual variability in the dynamics of natural accommodation in humans: relation to age and refractive errors. , 1993, The Journal of physiology.
[22] J. Robson,et al. High-speed infrared optometer. , 1959, Journal of the Optical Society of America.
[23] S Phillips,et al. ANALYSIS OF ACCOMMODATIVE RESPONSE TIMES USING HISTOGRAM INFORMATION* , 1972, American journal of optometry and archives of American Academy of Optometry.
[24] Optics of photorefraction: orthogonal and isotropic methods. , 1983, Journal of the Optical Society of America.
[25] M Millodot,et al. The relationship between tonic accommodation and refractive error. , 1987, Investigative ophthalmology & visual science.
[26] H C Howland,et al. Photorefraction: a technique for study of refractive state at a distance. , 1974, Journal of the Optical Society of America.