Remote pulmonary function testing using a depth sensor

We propose a remote non-invasive approach to Pulmonary Function Testing using a time-of-flight depth sensor (Microsoft Kinect V2), and correlate our results to clinical-standard spirometry results. Given point clouds, we approximate 3D models of the subject's chest, estimate the volume throughout a sequence and construct volume-time and flow-time curves for two prevalent spirometry tests: Forced Vital Capacity and Slow Vital Capacity. From these, we compute clinical measures, such as FVC, FEV1, VC and IC. We correlate automatically extracted measures with clinical spirometry tests on 40 patients in an outpatient hospital setting. These demonstrate high within-test correlations.

[1]  Lorenzo Scalise,et al.  Non contact measurement of heart and respiration rates based on Kinect™ , 2014, 2014 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[2]  Swb Manual of Clinical Problems in Pulmonary Medicine , 1992 .

[3]  Maysam Ghovanloo,et al.  A passive quantitative measurement of airway resistance using depth data , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Joan Lasenby,et al.  SLP: A Zero-Contact Non-Invasive Method for Pulmonary Function Testing , 2010, BMVC.

[5]  Jon Howard,et al.  Accurate markerless respiratory tracking for gated whole body PET using the Microsoft Kinect , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[6]  R. Stiefelhagen,et al.  Breath rate monitoring during sleep using near-ir imagery and PCA , 2012, Proceedings of the 21st International Conference on Pattern Recognition (ICPR2012).

[7]  Fatemeh Tahavori,et al.  Marker-less respiratory motion modeling using the Microsoft Kinect for Windows , 2014, Medical Imaging.

[8]  Junyi Xia,et al.  A real-time respiratory motion monitoring system using KINECT: proof of concept. , 2012, Medical physics.

[9]  Edgar A. Bernal,et al.  Non contact monitoring of respiratory function via depth sensing , 2014, IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).

[10]  J. Hankinson,et al.  Standardisation of spirometry , 2005, European Respiratory Journal.

[11]  H. Aoki,et al.  Non-contact respiration measurement using structured light 3-D sensor , 2012, 2012 Proceedings of SICE Annual Conference (SICE).

[12]  Joseph D. Bronzino,et al.  The Biomedical Engineering Handbook: Second Edition. , 1999 .

[13]  Joachim Hornegger,et al.  Robust real-time 3D respiratory motion detection using time-of-flight cameras , 2008, International Journal of Computer Assisted Radiology and Surgery.

[14]  Joseph D. Bronzino,et al.  The Biomedical Engineering Handbook , 1995 .

[15]  S. Longhi,et al.  Respiratory rate detection algorithm based on RGB-D camera: theoretical background and experimental results. , 2014, Healthcare technology letters.

[16]  Ming-Sui Lee,et al.  Noncontact respiratory measurement of volume change using depth camera , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.