The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair.

AIMS The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair. PATIENTS AND METHODS Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% β-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro β-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter). RESULTS A perianchor fluid signal was seen in three patients (8.1%) with anchor A, four (10.8%) with anchor B, 15 (41.7%) with anchor C, and 15 (41.7%) with anchor D. The severity of the collection around anchor was grade 2:1:0:0 for anchor A, grade 2:2:0:0 for anchor B, grade 12:2:0:1 for anchor C, and grade 11:3:0:1 for anchor D (grade 1:2:3:4, respectively). The prevalence and severity of fluid formation was not significantly different between anchors A and B, and anchors C and D. However, on intergroup analysis, there were significant differences for the prevalence and severity of fluid formation between anchors in group 1 and group 2. The prevalence of failure to heal was not significant in group 1 (seven, 18.9%) or group 2 (nine, 25.0%). There was no relationship between the presence of perianchor fluid and each type of anchor, and the integrity of the rotator cuff repair, in either group. CONCLUSION Despite the nonabsorbable nature of all-suture and PEEK anchors, all-suture anchors produced less osseous reaction after rotator cuff repair. In deciding which kind of anchor to use, consideration should be given not only to the strength of the initial fixation, but also to the postoperative biological reaction. Cite this article: Bone Joint J 2019;101-B:1506-1511.

[1]  M. Pouillon,et al.  Rotator cuff repair with all-suture anchors: a midterm magnetic resonance imaging evaluation of repair integrity and cyst formation. , 2018, Journal of shoulder and elbow surgery.

[2]  M. Herbert,et al.  All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode. , 2017, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[3]  A. Carr,et al.  Mechanical properties of all-suture anchors for rotator cuff repair , 2017, Bone & joint research.

[4]  G. Diederichs,et al.  Serial MRI evaluation following arthroscopic rotator cuff repair in double-row technique , 2016, Archives of Orthopaedic and Trauma Surgery.

[5]  O. Verborgt,et al.  Radiological and clinical outcome of arthroscopic labral repair with all-suture anchors. , 2015, Acta orthopaedica Belgica.

[6]  Ji Soon Park,et al.  Perianchor Cyst Formation Around Biocomposite Biodegradable Suture Anchors After Rotator Cuff Repair , 2015, The American journal of sports medicine.

[7]  E. McCarty,et al.  Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model. , 2015, Clinical biomechanics.

[8]  Barber Fa Complications of Biodegradable Materials: Anchors and Interference Screws. , 2015 .

[9]  W. S. Pietrzak,et al.  Triple labrum tears repaired with the JuggerKnot™ soft anchor: Technique and results , 2015, International journal of shoulder surgery.

[10]  Ferris M. Pfeiffer,et al.  The histologic and biomechanical response of two commercially available small glenoid anchors for use in labral repairs. , 2014, Journal of shoulder and elbow surgery.

[11]  Joo Han Oh,et al.  Postoperative Imaging of Bioabsorbable Anchors in Rotator Cuff Repair , 2014, The American journal of sports medicine.

[12]  D. Bokor,et al.  Perianchor radiolucency following PEEK suture anchor application associated with recurrent shoulder dislocation: a case report. , 2014, La Clinica terapeutica.

[13]  Sophie Le Cann,et al.  Pullout strength of all suture anchors in the repair of rotator cuff tears: a biomechanical study , 2013, International Orthopaedics.

[14]  G. Diederichs,et al.  Arthroscopic double-row repair of the rotator cuff: a comparison of bio-absorbable and non-resorbable anchors regarding osseous reaction , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[15]  N. Ghodadra,et al.  Complications of Bioabsorbable Suture Anchors in the Shoulder , 2012, The American journal of sports medicine.

[16]  Y. Ozturkmen,et al.  Effect of PEEK polymer on tunnel widening after hamstring ACL reconstruction. , 2012, Orthopedics.

[17]  M. Baums,et al.  Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor , 2010, Archives of Orthopaedic and Trauma Surgery.

[18]  Jinyoung Park,et al.  Perianchor Radiolucency after Knotless Anchor Repair for Shoulder Instability , 2009, The American journal of sports medicine.

[19]  H. Sugaya,et al.  Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. , 2007, The Journal of bone and joint surgery. American volume.

[20]  G. Athwal,et al.  Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. , 2006, The Journal of bone and joint surgery. American volume.

[21]  E. Schneider,et al.  Osseous integration of poly-(L-co-D/L-lactide) 70/30 and titanium suture anchors: an experimental study in sheep cancellous bone. , 2002, Injury.

[22]  R. Cofield,et al.  Results of a second attempt at surgical repair of a failed initial rotator-cuff repair. , 1984, The Journal of bone and joint surgery. American volume.