Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

[1]  Brandon McCarron Low-Cost IMU Implementation via Sensor Fusion Algorithms in the Arduino Environment , 2013 .

[2]  Jerry Banks,et al.  Recent Advances in the Technology , 2007 .

[3]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[4]  D McLean,et al.  The effect of source to image-receptor distance on effective dose for some common X-ray projections. , 2005, The British journal of radiology.

[5]  Kenneth L. Bontrager Textbook of Radiographic Positioning and Related Anatomy , 1987 .

[6]  Masayuki Zuguchi,et al.  Quality Control Phantom for Flat Panel Detector X-ray Systems , 2013, Health physics.

[7]  Thomas Lehnert,et al.  Novel, portable, cassette-sized, and wireless flat-panel digital radiography system: initial workflow results versus computed radiography. , 2011, AJR. American journal of roentgenology.

[8]  Stephen Balter,et al.  Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190. , 2015, Medical physics.

[9]  Jinseok Lee,et al.  Dedicated mobile volumetric cone-beam computed tomography for human brain imaging: A phantom study. , 2015, Journal of X-ray science and technology.

[10]  Maximilian F Reiser,et al.  Advances in digital radiography: physical principles and system overview. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  Ibrahim Alkatout,et al.  [Communicative and ethical aspects of physician-patient relationship in extreme situations]. , 2015, Wiener medizinische Wochenschrift.

[12]  Kenneth H Cho,et al.  Digital radiography for the field: a portable prototype. , 2002, Journal of digital imaging.

[13]  J. Dinten,et al.  A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup , 2007, Physics in medicine and biology.

[14]  Luís Lança,et al.  Digital radiography detectors – A technical overview: Part 2 , 2009 .

[15]  M. Prokop,et al.  DR and CR: Recent advances in technology. , 2009, European journal of radiology.

[16]  Luís Lança,et al.  Digital Radiography Detectors: A Technical Overview , 2013 .

[17]  Joy Conway,et al.  Professional articlesReliability: What is it, and how is it measured?Funding , 2000 .

[18]  Stephen T. Holgate,et al.  Reliability: What is it, and how is it measured? , 2000 .

[19]  K Eckerman,et al.  ICRP Publication 119: Compendium of dose coefficients based on ICRP Publication 60. , 2012, Annals of the ICRP.

[20]  Walter Heindel,et al.  Portable Flat-Panel Detector for Low-Dose Imaging in a Pediatric Intensive Care Unit: Comparison With an Asymmetric Film-Screen System , 2005, Investigative radiology.

[21]  Chung-Feng Liu,et al.  Managing Repeat Digital Radiography Images—A Systematic Approach and Improvement , 2011, Journal of Medical Systems.

[22]  Alessandro D’Ausilio,et al.  Arduino: A low-cost multipurpose lab equipment , 2011, Behavior Research Methods.

[23]  B.S. Lee,et al.  Development of a portable digital radiographic system based on FOP-coupled CMOS image sensor and its performance evaluation , 2005, IEEE Transactions on Nuclear Science.

[24]  E. Georgiou,et al.  Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study , 2006, Physics in medicine and biology.