Automated spinal cord monitoring for spinal surgery

A microcomputer-based automated spinal cord monitoring system was developed and 56 spinal operations have been carried out with it since 1986. The system comprises an electrodiagnostic system (Dantec 2000M), an FM tape recorder, a channel selector, an electrical relay, a Modem and a microcomputer which controls all of the elements. The program allowed for automated recording and analysis of evoked potentials during spinal surgery and alarm signals were generated according to the criteria of amplitude decrease and latency delay. It was demonstrated that automated spinal cord monitoring in the operating room was performed easily, reliably and safely allowing the surgeon to react quickly to possible compromise of the spinal cord. The design and usefulness of the system is described in this report.

[1]  P. Pellicci,et al.  Nerve injury in total hip arthroplasty. , 1983, Clinical orthopaedics and related research.

[2]  C. L. Nash,et al.  Spinal cord monitoring during operative treatment of the spine. , 1977, Clinical orthopaedics and related research.

[3]  W. Bunch,et al.  Spinal cord monitoring. , 1983, The Journal of bone and joint surgery. American volume.

[4]  C. L. Nash,et al.  Spinal cord monitoring. , 1989, The Journal of bone and joint surgery. American volume.

[5]  N. P. Thomas,et al.  A system for the electrophysiological monitoring of the spinal cord during operations for scoliosis. , 1983, The Journal of bone and joint surgery. British volume.

[6]  W. Friedman,et al.  Somatosensory evoked potential monitoring of spinal cord ischemia during aortic operations. , 1986, Neurosurgery.

[7]  M. Hajdu,et al.  Evaluation of sciatic nerve compromise during total hip arthroplasty. , 1985, Clinical orthopaedics and related research.

[8]  E Micheli-Tzanakou,et al.  Collection and storage of data for evoked potential studies: a database. , 1984, Computer programs in biomedicine.

[9]  J. R. Boston,et al.  Sensory evoked potentials: a system for clinical testing and patient monitoring , 1984, International journal of clinical monitoring and computing.

[10]  A. Alter Somatosensory evoked potentials during harrington instrumentation for scoliosis , 1979 .

[11]  H. Tullos,et al.  Contributory factors and etiology of sciatic nerve palsy in total hip arthroplasty. , 1987, Clinical orthopaedics and related research.

[12]  Philip A. Parker,et al.  Microprocessor-Based System for Monitoring Spinal Evoked Potentials During Surgery , 1986, IEEE Transactions on Biomedical Engineering.

[13]  J. Daube,et al.  Peripheral neuropathies associated with total hip arthroplasty. , 1976, The Journal of bone and joint surgery. American volume.