Human factors impact successful lay person automated external defibrillator use during simulated cardiac arrest

Objective:With the dissemination of automated external defibrillators in the community, there is increasing lay person use, along with less formal automated external defibrillator training and retraining. Therefore, the “ease of use” factors related to the human-device interface may be vital for successful use. We sought to determine whether human factor differences would result in differences in parameters of successful or safe use by lay persons in the setting of simulated cardiac arrest. Methods:We measured parameters of successful and safe use with two automated external defibrillator devices among two groups of volunteers, those trained with a brief video tape and those without any training (completely naive). Both devices (the Philips FR2 or the HS1) are used in public access defibrillator settings. Volunteers entered a mock cardiac arrest scenario after randomization to either the naive (untrained) group or to a video-trained group. Results:Both the FR2 and HS1 were found to be completely safe when used by video-trained and by naive groups of participants, with no adverse events observed (total, n = 256). For both devices, video-trained participants demonstrated high rates of successful defibrillation in the simulated testing (86% for FR2 and 89% for HS1). With the FR2, video-trained participants were significantly more successful compared with naive, untrained participants (86% vs. 48% successful use; p < .001). However, for the HS1, there was no significant difference in success rates for the video-trained vs. naive, untrained groups (89% vs. 87%; p = .79). Conclusions:Both devices are safe with either video-trained or naive users. The successful use of each device is high when participants view the training videotape designed for the device. An important difference in successful use was observed for naive users where the HS1 showed improved successful use compared with the FR2. Because defibrillation in the community may increasingly be attempted by lay persons whose training is remote or who have not been trained at all, the “naive” scenario may be increasingly relevant to automated external defibrillator use. Collectively, these data support the notion that human factors associated with ease of use may play a critical factor in survival rates achieved by specific devices.

[1]  P. Paris,et al.  Use of automated external defibrillators by police officers for treatment of out-of-hospital cardiac arrest. , 1998, Annals of emergency medicine.

[2]  R. Newcombe,et al.  Skill acquisition and retention in automated external defibrillator (AED) use and CPR by lay responders: a prospective study. , 2004, Resuscitation.

[3]  L. Kuller,et al.  Epidemiology of sudden death. , 1972, Archives of internal medicine.

[4]  J S Geddes,et al.  An airline cardiac arrest program. , 1997, Circulation.

[5]  D J Roe,et al.  Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos. , 2000, The New England journal of medicine.

[6]  A Hallstrom,et al.  The ACLS score. Predicting survival from out-of-hospital cardiac arrest. , 1981, JAMA.

[7]  Sandeep Vijan,et al.  Public use of automated external defibrillators. , 2003, The New England journal of medicine.

[8]  Roger D. White,et al.  Seven years' experience with early defibrillation by police and paramedics in an emergency medical services system. , 1998, Resuscitation.

[9]  P. Larsen,et al.  Comparison of ease of use of three automated external defibrillators by untrained lay people. , 2003, Resuscitation.

[10]  G. Sanders,et al.  Cost-effectiveness of automated external defibrillators on airlines. , 2001, JAMA.

[11]  S. Lai,et al.  Impact of Community-Wide Police Car Deployment of Automated External Defibrillators on Survival From Out-of-Hospital Cardiac Arrest , 2002, Circulation.

[12]  M. Copass,et al.  Improved neurologic recovery and survival after early defibrillation. , 1984, Circulation.

[13]  Gust H. Bardy,et al.  Tripling Survival From Sudden Cardiac Arrest Via Early Defibrillation Without Traditional Education in Cardiopulmonary Resuscitation , 2002, Circulation.

[14]  岡田 和夫,et al.  話題 「Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care--International Consensus on Science」の日本における普及と取り組み , 2001 .

[15]  R. Swor,et al.  Estimated cost effectiveness of a police automated external defibrillator program in a suburban community: 7 years experience. , 2002, Resuscitation.

[16]  R. MacDonald,et al.  I MPACT OF P ROMPT D EFIBRILLATION ON C ARDIAC A RREST AT A M AJOR I NTERNATIONAL A IRPORT , 2002, Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors.

[17]  R O Cummins,et al.  From concept to standard-of-care? Review of the clinical experience with automated external defibrillators. , 1989, Annals of emergency medicine.

[18]  Wanchun Tang,et al.  Cardiopulmonary resuscitation: a promise as yet largely unfulfilled. , 1997, Disease-a-month : DM.

[19]  P. J. Wang,et al.  Improving survival from sudden cardiac arrest: the role of the automated external defibrillator. , 2001, JAMA.

[20]  D J Roe,et al.  Estimating effectiveness of cardiac arrest interventions: a logistic regression survival model. , 1997, Circulation.

[21]  Roger D. White,et al.  Patient outcomes following defibrillation with a low energy biphasic truncated exponential waveform in out-of-hospital cardiac arrest. , 2001, Resuscitation.

[22]  J. Ornato,et al.  Improving survival from sudden cardiac arrest: the "chain of survival" concept. A statement for health professionals from the Advanced Cardiac Life Support Subcommittee and the Emergency Cardiac Care Committee, American Heart Association. , 1991, Circulation.

[23]  R. Virmani,et al.  Sudden cardiac death. , 1987, Human pathology.

[24]  P. Spooner,et al.  Opportunities for sudden death prevention: directions for new clinical and basic research. , 2001, Cardiovascular research.

[25]  Sherry Caffrey,et al.  Feasibility of public access to defibrillation , 2002, Current opinion in critical care.

[26]  George A. Mensah,et al.  Sudden Cardiac Death in the United States, 1989 to 1998 , 2001, Circulation.