The effects of different wire and screw combinations on the stiffness of a hybrid external fixator
暂无分享,去创建一个
[1] K. Tanner,et al. An engineering evaluation of the Oxford External Fixator with sliding clamps: fixator stiffness and fracture healing assessment. , 1985, Engineering in medicine.
[2] J R Davey,et al. Stability of ten configurations of the Hoffmann external-fixation frame. , 1987, The Journal of bone and joint surgery. American volume.
[3] A. E. Goodship,et al. EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURES , 1986, The Lancet.
[4] R. Huiskes,et al. Guidelines for external fixation frame rigidity and stresses , 1986, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[5] G A Ilizarov,et al. The tension-stress effect on the genesis and growth of tissues: Part II. The influence of the rate and frequency of distraction. , 1989, Clinical orthopaedics and related research.
[6] E Y Chao,et al. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators. , 1993, Clinical orthopaedics and related research.
[7] K E Tanner,et al. The Oxford External Fixator: fixator stiffness and the effects of bone pin loosening. , 1985, Engineering in medicine.
[8] J. L. Marsh,et al. Unilateral external fixation until healing with the dynamic axial fixator for severe open tibial fractures. , 1991, Journal of orthopaedic trauma.
[9] G A Ilizarov,et al. The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation. , 1989, Clinical orthopaedics and related research.
[10] A. Goodship,et al. Cortical profile external fixation screws maintain torque in the metaphysis , 1997 .
[11] C. Brown,et al. Surgical treatment of patients with open tibial fractures. , 1996, AORN journal.
[12] M. Saleh,et al. Bifocal surgery for deformity and bone loss after lower-limb fractures. Comparison of bone-transport and compression-distraction methods. , 1995, The Journal of bone and joint surgery. British volume.
[13] E. Chao,et al. The effects of physiologic dynamic compression on bone healing under external fixation. , 1990, Clinical orthopaedics and related research.
[14] E Schneider,et al. Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators. , 1990, Journal of biomechanical engineering.
[15] E. Chao,et al. Comparison of osteotomy healing under external fixation devices with different stiffness characteristics. , 1984, The Journal of bone and joint surgery. American volume.
[16] A. Mallik,et al. Hybrid external fixation in tibial plafond fractures. , 1996, Clinical orthopaedics and related research.
[17] D. Seligson,et al. Fracture site motion with Ilizarov and "hybrid" external fixation. , 1998, Journal of orthopaedic trauma.
[18] H. Boxma,et al. Performance of external fixation devices in femoral fractures; the ultimate challenge? A laboratory study with plastic rods. , 1990, Injury.
[19] P. Tornetta,et al. Pilon Fractures: Treatment With Combined Internal and External Fixation , 1993, Journal of orthopaedic trauma.
[20] W. Hutton,et al. Biomechanical comparison of hybrid external fixators. , 1998, Journal of orthopaedic trauma.
[21] M. Saleh,et al. Management of nonunion of fractures by distraction with correction of angulation and shortening. , 1996, The Journal of bone and joint surgery. British volume.
[22] E. Chao,et al. Cortical bone reactions at the interface of external fixation half-pins under different loading conditions. , 1993, The Journal of trauma.