Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings.

UNLABELLED Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R(2) = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R(2) = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings. PRACTICAL IMPLICATIONS As control of indoor microbial contamination has become an increasing concern around the world, feasibility and effectiveness of adopting ventilation approach has attracted a significant interest. This field investigation demonstrated, quantitatively, critical variables to be taken into consideration while applying such a measure, including the kinds of microbes to be removed and the types of ventilation system already in place.

[1]  R. Gots,et al.  Indoor health: background levels of fungi. , 2003, AIHA Journal.

[2]  R. Dales,et al.  Indoor air quality and health: validity and determinants of reported home dampness and moulds. , 1997, International journal of epidemiology.

[3]  R. Simmons,et al.  Fungal colonization of air filters from hospitals. , 1997, American Industrial Hygiene Association journal.

[4]  B. Szponar,et al.  Microorganisms and volatile organic compounds in airborne dust from damp residences. , 2004, Indoor air.

[5]  A. Geyh,et al.  The Ability of Hospital Ventilation Systems to Filter Aspergillus and Other Fungi Following a Building Implosion , 2002, Infection Control &#x0026; Hospital Epidemiology.

[6]  Vidas K. Paulius,et al.  Indoor air quality in a middle school, Part II: Development of emission factors for particulate matter and bioaerosols. , 2000, Applied occupational and environmental hygiene.

[7]  Harriet A. Burge,et al.  Dynamics of Airborne Fungal Populations in a Large Office Building , 2000, Current Microbiology.

[8]  D. Pierson,et al.  Fungal Colonization of Air Filters and Insulation in a Multi-Story Office Building: Production of Volatile Organics , 1997, Current Microbiology.

[9]  Jorge Kalil,et al.  Upper respiratory symptoms associated with aging of the ventilation system in artificially ventilated offices in São Paulo, Brazil. , 2002, Chest.

[10]  H. Burge,et al.  Dustborne and airborne fungal propagules represent a different spectrum of fungi with differing relations to home characteristics , 2003, Allergy.

[11]  R. Bholah,et al.  Indoor biological contaminants and symptoms of sick building syndrome in office buildings in Mauritius , 2002, International journal of environmental health research.

[12]  D. Jarvis,et al.  Environmental and occupational disorders Housing characteristics, reported mold exposure, and asthma in the European Community Respiratory Health Survey , 2002 .

[13]  J. Schillinger,et al.  Airborne Fungi and Bacteria: Background Levels in Office Buildings , 1999 .

[14]  G. Pershagen,et al.  Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP). , 2001, Indoor air.

[15]  C. S. Li,et al.  Airborne fungus allergen in association with residential characteristics in atopic and control children in a subtropical region. , 1997, Archives of environmental health.

[16]  Q Chen,et al.  Air flow and particle control with different ventilation systems in a classroom. , 2003, Indoor air.

[17]  E. Faragher,et al.  An investigation of the relationship between microbial and particulate indoor air pollution and the sick building syndrome. , 1992, Respiratory medicine.

[18]  W Pei-Chih,et al.  Characteristics of indoor and outdoor airborne fungi at suburban and urban homes in two seasons. , 2000, The Science of the total environment.

[19]  B. Shelton,et al.  Profiles of Airborne Fungi in Buildings and Outdoor Environments in the United States , 2002, Applied and Environmental Microbiology.

[20]  J. D. Cooley,et al.  Correlation between the prevalence of certain fungi and sick building syndrome. , 1998, Occupational and environmental medicine.

[21]  S. R. Wynn,et al.  Effect of heating-ventilation-air conditioning system sanitation on airborne fungal populations in residential environments. , 1993, Annals of allergy.

[22]  P. C. Kemp,et al.  Changes in airborne fungi from the outdoors to indoor air; large HVAC systems in nonproblem buildings in two different climates. , 2003, AIHA journal : a journal for the science of occupational and environmental health and safety.

[23]  Chung Kc Airborne contaminant exposure control in a partitioned work environment by exhaust ventilation systems. , 1998 .

[24]  B. Brunekreef,et al.  Associations between questionnaire reports of home dampness and childhood respiratory symptoms. , 1992, The Science of the total environment.

[25]  Chi Kwan Chau,et al.  Characteristics of bioaerosol profile in office buildings in Hong Kong , 2001 .

[26]  Hsiu-Ling Chen,et al.  Exposure assessment of indoor allergens, endotoxin, and airborne fungi for homes in southern Taiwan. , 2001, Environmental research.

[27]  C. Hsu,et al.  Indoor pollution and sick building syndrome symptoms among workers in day-care centers. , 1997, Archives of environmental health.

[28]  F. Staib Pathogenic fungi in human dwellings * , 1992, Mycoses.

[29]  B. Dhorranintra,et al.  A comparative study of the incidence of indoor and outdoor mold spores in Bangkok, Thailand. , 1982, Annals of allergy.

[30]  L. Dotterud,et al.  Viable fungi in indoor air in homes and schools in the Sør‐Varanger community during winter , 1995, Pediatric allergy and immunology : official publication of the European Society of Pediatric Allergy and Immunology.

[31]  J T Jankovic,et al.  Occupant generated carbon dioxide as a measure of dilution ventilation efficiency. , 1996, American Industrial Hygiene Association journal.