Quantification of 3-D field effects during 2-D microwave imaging

Two-dimensional (2-D) approaches to microwave imaging have dominated the research landscape primarily due to the moderate levels of measurement data, data-acquisition time, and computational costs required. Three-dimensional (3-D) approaches have been investigated in simulation, phantom, and animal experiments. While 3-D approaches are certainly important in terms of the potential to improve image quality, their associated costs are significant at this time. In addition, benchmarks are needed to evaluate these new generation systems as more 3-D methods begin to appear. In this paper, we present a systematic series of experiments which assess the capability of our 2-D system to image classical 3-D geometries. We demonstrate where current methods suffer from 3-D effects but also identify situations where they remain quite useful. Comparisons between reconstructions utilizing phantom measurements and simulated 3-D data are also shown to validate the results. These findings suggest that for certain biomedical applications, 2-D approaches remain quite attractive.

[1]  K. Paulsen,et al.  Finite element computations of specific absorption rates in anatomically conforming full-body models for hyperthermia treatment analysis , 1993, IEEE Transactions on Biomedical Engineering.

[2]  K D Paulsen,et al.  A two-stage microwave image reconstruction procedure for improved internal feature extraction. , 2001, Medical physics.

[3]  Constantine A. Balanis,et al.  Antenna Theory: Analysis and Design , 1982 .

[4]  K. Paulsen,et al.  Radiation boundary conditions for finite element solutions of generalized wave equations , 1991 .

[5]  K D Paulsen,et al.  Optimization of pelvic heating rate distributions with electromagnetic phased arrays. , 1999, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[6]  K. Paulsen,et al.  Evaluation of perfectly matched layer mesh terminations in finite-element bioelectromagnetic scattering computations , 1999 .

[7]  M. Pastorino,et al.  Redundant electromagnetic data for microwave imaging of three-dimensional dielectric objects , 1994 .

[8]  A. Bulyshev,et al.  Three-dimensional microwave tomography: experimental prototype of the system and vector Born reconstruction method , 1999, IEEE Transactions on Biomedical Engineering.

[9]  L. Jofre,et al.  Medical imaging with a microwave tomographic scanner , 1990, IEEE Transactions on Biomedical Engineering.

[10]  Robert H. Svenson,et al.  Three-dimensional microwave tomography: experimental imaging of phantoms and biological objects , 2000 .

[11]  Keith D. Paulsen,et al.  A three-dimensional mesh generator for arbitrary multiple material domains , 1997 .

[12]  Paul M. Meaney,et al.  Nonactive antenna compensation for fixed-array microwave imaging. I. Model development , 1999, IEEE Transactions on Medical Imaging.

[13]  Robert H. Svenson,et al.  Spatial resolution of microwave tomography for detection of myocardial ischemia and infarction-experimental study on two-dimensional models , 2000 .

[14]  C. Pichot,et al.  Inverse scattering: an iterative numerical method for electromagnetic imaging , 1991 .

[15]  S.Y. Semenov,et al.  Microwave tomography: two-dimensional system for biological imaging , 1996, IEEE Transactions on Biomedical Engineering.

[16]  P.M. Meaney,et al.  Microwave imaging for tissue assessment: initial evaluation in multitarget tissue-equivalent phantoms , 1996, IEEE Transactions on Biomedical Engineering.

[17]  Keith D. Paulsen,et al.  Perfectly matched layer mesh terminations for nodal-based finite-element methods in electromagnetic scattering , 1998 .

[18]  A. W. Guy,et al.  Analyses of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom Models , 1971 .

[19]  Matteo Pastorino,et al.  Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method , 1993, IEEE Trans. Medical Imaging.

[20]  K D Paulsen,et al.  Finite element simulation of Sigma 60 heating in the Utah phantom: computed and measured data compared. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[21]  Paul M. Meaney,et al.  Nonactive antenna compensation for fixed-array microwave imaging. II. Imaging results , 1999, IEEE Transactions on Medical Imaging.

[22]  P.M. Meaney,et al.  An active microwave imaging system for reconstruction of 2-D electrical property distributions , 1995, IEEE Transactions on Biomedical Engineering.

[23]  R. Freund Quasi-kernel polynomials and their use in non-Hermitian matrix iterations , 1992 .