Performance analysis of Ethernet Powerlink networks for distributed control and automation systems

Industrial communication networks are a key element for developing advanced distributed control and automation systems. On the one hand, high performance and low costs are generally required to cope with more and more demanding application requirements, while, on the other hand, real-time capabilities are often needed in an increasing number of automation scenarios. Communication solutions based on Ethernet technologies are becoming popular in many industrial and factory environments and a number of soft/hard real-time competing products have been proposed in the last few years. This paper focuses on the Ethernet Powerlink standard, in general, and on some of its real-time characteristics, in particular. In fact, we present some basic results concerning both cyclic and acyclic real-time traffic in Ethernet Powerlink networks, obtained by extensive simulation, which can be used as a basic step for a better understanding of the real-time behavior of this protocol.

[1]  Ieee Standards Board IEEE standards for local and metropolitan area networks : supplement to Carrier Sense Multiple Access with Collision Detection (CSMA/CD) access method and physical layer specifications : layer management (section 5) , 1991 .

[2]  E. Gilbert Capacity of a burst-noise channel , 1960 .

[3]  Leonard Kleinrock,et al.  Theory, Volume 1, Queueing Systems , 1975 .

[4]  George W. Zobrist,et al.  Intelligent Systems and Robotics , 2000 .

[5]  R. Scopigno,et al.  A Methodology for the Analysis of 802.11a Links in Industrial Environments , 2006, 2006 IEEE International Workshop on Factory Communication Systems.

[6]  Andreas Willig,et al.  Ring stability of the PROFIBUS token-passing protocol over error-prone links , 2001, IEEE Trans. Ind. Electron..

[7]  Boudewijn R. Haverkort,et al.  Performance of computer communication systems - a model-based approach , 1998 .

[8]  T. Sauter,et al.  The continuing evolution of integration in manufacturing automation , 2007, IEEE Industrial Electronics Magazine.

[9]  Suk Lee,et al.  Worst Case Communication Delay of Real-Time Industrial Switched Ethernet With Multiple Levels , 2006, IEEE Transactions on Industrial Electronics.

[10]  Jean-Pierre Thomesse,et al.  Fieldbus Technology in Industrial Automation , 2005, Proceedings of the IEEE.

[11]  James Moyne,et al.  Performance evaluation of control networks: Ethernet, ControlNet, and DeviceNet , 2001 .

[12]  Jean-Dominique Decotignie,et al.  Ethernet-Based Real-Time and Industrial Communications , 2005, Proceedings of the IEEE.

[13]  Krithi Ramamritham,et al.  Hard Real-Time Systems , 1988 .

[14]  João Pedro Hespanha,et al.  A Survey of Recent Results in Networked Control Systems , 2007, Proceedings of the IEEE.

[15]  Stefano Vitturi,et al.  A simulation study of ethernet powerlink networks , 2007, 2007 IEEE Conference on Emerging Technologies and Factory Automation (EFTA 2007).

[16]  Andreas Willig,et al.  Measurements of a wireless link in an industrial environment using an IEEE 802.11-compliant physical layer , 2002, IEEE Trans. Ind. Electron..