Instability of a geogrid reinforced soil wall on thick soft Shanghai clay with prefabricated vertical drains: A case study

Abstract A 7.6 m high geogrid reinforced soil retaining wall (RSW) was constructed at the end of an embankment on very thick, soft Shanghai clay with 12 m deep prefabricated vertical drains (PVDs). The settlement of the ground, the wall movement and pore water pressure were monitored during the construction. From day 118, halfway through the construction, unexpected pore water pressure increment was recorded from the pore water pressure meters installed in the PVD drained zone indicating a possible malfunction of the PVDs due to large deformation in the ground. After the last loading stage, on day 190, a sudden horizontal movement at the toe was observed, followed by an arc shaped crack on the embankment surface at the end of the reinforced backfill zones. The wall was analyzed with a coupled mechanical and hydraulic finite element (FE) model. The analysis considered two scenarios: one with PVDs fully functional, and the second one with PVD failure after day 118 by manually deactivating the PVDs in the FE model. The comparison between the measured and simulated ground settlement, toe movement, and pore water pressure supported the assumption on the malfunction of the PVDs. It is believed that the general sliding failure in the wall was caused by the increase of pore water pressure in the foundation soil and soils in front of the toe. It is suggested that possible failure of PVDs should be considered in the design of such structures, and the discharge rate of the PVDs and the pore water pressure should be closely monitored during the construction of high soil walls on soft soils to update the stability of the structures, especially for grounds where large deformations are expected which may cause the failure of the PVDs.

[1]  G. D. Skinner,et al.  Design and behaviour of a geosynthetic reinforced retaining wall and bridge abutment on a yielding foundation , 2005 .

[2]  D. T. Bergado,et al.  Measured and simulated results of a Kenaf Limited Life Geosynthetics (LLGs) reinforced test embankment on soft clay , 2014 .

[3]  Norihiko Miura,et al.  INVESTIGATION OF FACTORS AFFECTING VERTICAL DRAIN BEHAVIOR , 1999 .

[4]  Mustafa Laman,et al.  Large scale field tests on geogrid-reinforced granular fill underlain by clay soil , 2013 .

[5]  J. N. Mandal,et al.  DESIGN OF GEOSYNTHETIC REINFORCED EMBANKMENTS ON SOFT SOIL , 1996 .

[6]  V. Choa,et al.  Improvement of ultra-soft soil using prefabricated vertical drains , 2006 .

[7]  Chung-Sik Yoo,et al.  Performance of a two-tier geosynthetic reinforced segmental retaining wall under a surcharge load: Full-scale load test and 3D finite element analysis , 2008 .

[8]  Dov Leshchinsky,et al.  Post-earthquake investigation on several geosynthetic-reinforced soil retaining walls and slopes during the Ji-Ji earthquake of Taiwan , 2001 .

[9]  Y. M. Cheng,et al.  Two-dimensional slope stability analysis by limit equilibrium and strength reduction methods , 2007 .

[10]  Jonathan D. Bray,et al.  Collapse of Geogrid-Reinforced Retaining Structure , 1994 .

[11]  H Ochiai,et al.  Performance of mechanically stabilized earth walls over compressible soils , 2001 .

[12]  Taro Uchimura,et al.  Geosynthetic-Reinforced Soil Retaining Walls as Important Permanent Structures 1996 - 1997 Mercer Lecture , 1997 .

[13]  Robert M. Koerner,et al.  A data base, statistics and recommendations regarding 171 failed geosynthetic reinforced mechanically stabilized earth (MSE) walls , 2013 .

[14]  James G. Collin LESSONS LEARNED FROM A SEGMENTAL RETAINING WALL FAILURE , 2001 .

[15]  S. H. Mirmoradi,et al.  Evaluation of the effects of facing stiffness and toe resistance on the behavior of GRS walls , 2013 .

[16]  Chung-Sik Yoo,et al.  MEASURED BEHAVIOR OF A GEOSYNTHETIC-REINFORCED SEGMENTAL RETAINING WALL IN A TIERED CONFIGURATION , 2004 .

[17]  Jessee A. Scarborough,et al.  A Tale of Two Walls: Case Histories of Failed MSE Walls , 2005 .

[18]  José Leitão Borges,et al.  OVERALL STABILITY OF GEOSYNTHETIC- REINFORCED EMBANKMENTS ON SOFT SOILS , 2002 .

[19]  B. V. S. Viswanadham,et al.  Centrifuge modeling of geotextile-reinforced slopes subjected to differential settlements , 2009 .

[20]  I. C. Pyrah,et al.  Modelling the effect of vertical drains in two-dimensional finite element analyses of embankments on soft ground , 1995 .

[21]  Jianfeng Xue,et al.  Micro-mechanism of the interaction between sand and geogrid transverse ribs , 2012 .

[22]  Dennes T. Bergado,et al.  A case study of geotextile-reinforced embankment on soft ground , 2002 .

[23]  F. Tavenas,et al.  Lateral displacements in clay foundations under embankments , 1979 .

[24]  D. T. Bergado,et al.  Deformation of Reinforced Soil Wall-Embankment System on Soft Clay Foundation , 1997 .

[25]  Dov Leshchinsky,et al.  Geosynthetic Reinforced Multitiered Walls , 2004 .

[26]  Jinchun Chai,et al.  Analysis of field performance of embankments on soft clay deposit with and without PVD-improvement , 2005 .

[27]  Chung-Sik Yoo,et al.  Case History of Geosynthetic Reinforced Segmental Retaining Wall Failure , 2006 .

[28]  G. D. Skinner,et al.  Numerical analysis of geosynthetic reinforced retaining wall constructed on a layered soil foundation , 2001 .

[29]  Xiaowu Tang,et al.  Closed-form solution for consolidation of three-layer soil with a vertical drain system , 2013 .

[30]  D. T. Bergado,et al.  Numerical simulation and sensitivity analyses of full-scale test embankment with reinforced lightweight geomaterials on soft Bangkok clay , 2008 .

[31]  S. Hansbo,et al.  Design aspects of vertical drains and lime column installations : Proc Ninth Southeast Asian Geotechnical Conference, Bangkok, 7–11 December 1987 V2, P8.1–8.12. Publ Bangkok: Southeast Asian Geotechnical Society, 1987 , 1990 .

[32]  B. V. S. Viswanadham,et al.  Centrifuge model study on low permeable slope reinforced by hybrid geosynthetics , 2011 .

[33]  Ching-Chuan Huang,et al.  Dynamic behavior of reinforced walls – Horizontal displacement response , 2011 .