Validity of Wearable Activity Monitors during Cycling and Resistance Exercise

IntroductionThe use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. MethodsFifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ⩽10%. ResultsThe Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. ConclusionsHR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.

[1]  Gregory J Welk,et al.  Comparison of Consumer and Research Monitors under Semistructured Settings. , 2016, Medicine and science in sports and exercise.

[2]  D. Hollander,et al.  Hormonal responses from concentric and eccentric muscle contractions. , 2003, Medicine and science in sports and exercise.

[3]  Steven Francis Leboeuf,et al.  Earbud-based sensor for the assessment of energy expenditure, HR, and VO2max. , 2014, Medicine and science in sports and exercise.

[4]  R. Kraemer,et al.  A Hydrothermally Processed Maize Starch and Its Effects on Blood Glucose Levels During High-Intensity Interval Exercise , 2018, Journal of strength and conditioning research.

[5]  Bryan K. Smith,et al.  Appropriate Physical Activity Intervention Strategies for Weight Loss and Prevention of Weight Regain for Adults Position Stand , 2022 .

[6]  S. Webber,et al.  Sedentary Behavior, Cadence, and Physical Activity Outcomes after Knee Arthroplasty , 2017, Medicine and science in sports and exercise.

[7]  Hoda Javadikasgari,et al.  Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise , 2017, Medicine and science in sports and exercise.

[8]  Gregory J Welk,et al.  Validity of consumer-based physical activity monitors. , 2014, Medicine and science in sports and exercise.

[9]  L. Houtkooper,et al.  Energy balance at a crossroads: translating the science into action. , 2014, Journal of the Academy of Nutrition and Dietetics.

[10]  D. Cook,et al.  Wearable Technology Reduces Prolonged Bouts of Sedentary Behavior , 2016 .

[11]  U. Wisløff,et al.  Accuracy of Heart Rate Watches: Implications for Weight Management , 2016, PloS one.

[12]  Trevor Hastie,et al.  Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort , 2016 .

[13]  D. Rafolt,et al.  Influence of contact forces on wrist photoplethysmography--prestudy for a wearable patient monitor. , 2004, Biomedizinische Technik. Biomedical engineering.

[14]  Larry Katz,et al.  Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise , 2017, Medicine and science in sports and exercise.

[15]  Toshiyo Tamura,et al.  The Advantages of Wearable Green Reflected Photoplethysmography , 2011, Journal of Medical Systems.

[16]  B. Dolezal,et al.  Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking. , 2016, Journal of sports science & medicine.

[17]  M Benjamin Nelson,et al.  Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types. , 2016, Medicine and science in sports and exercise.

[18]  M J Butler,et al.  Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin , 2016, Physiological measurement.

[19]  M. Fernández del Olmo,et al.  Set Configuration in Resistance Exercise: Muscle Fatigue and Cardiovascular Effects , 2016, PloS one.

[20]  Thea J. M. Kooiman,et al.  Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed , 2017, Medicine and science in sports and exercise.

[21]  Walter R. Thompson WORLDWIDE SURVEY OF FITNESS TRENDS FOR 2013 , 2012 .

[22]  S. Coughlin,et al.  Use of Consumer Wearable Devices to Promote Physical Activity: A Review of Health Intervention Studies , 2016, Journal of environment and health sciences.

[23]  V. Linnamo,et al.  Effects of a Heart Rate–Based Recovery Period on Hormonal, Neuromuscular, and Aerobic Performance Responses During 7 Weeks of Strength Training in Men , 2011, Journal of strength and conditioning research.

[24]  Guang-Zhong Yang,et al.  Wearable Sensing for Solid Biomechanics: A Review , 2015, IEEE Sensors Journal.

[25]  Walter R. Thompson,et al.  WORLDWIDE SURVEY OF FITNESS TRENDS FOR 2016: 10th Anniversary Edition , 2015 .

[26]  Dermot Phelan,et al.  Accuracy of Wrist-Worn Heart Rate Monitors , 2017, JAMA cardiology.

[27]  A. Jeukendrup,et al.  Heart Rate Monitoring , 2003, Sports medicine.

[28]  In Cheol Jeong,et al.  Effects of skin surface temperature on photoplethysmograph. , 2014, Journal of healthcare engineering.