A new calibration method for tri-axial field sensors in strap-down navigation systems

This paper presents a novel calibration method for tri-axial field sensors, such as magnetometers and accelerometers, in strap-down navigation systems. Strap-down tri-axial sensors have been widely used as they have the advantages of small size and low cost, but they need to be calibrated in order to ensure their accuracy. The most commonly used calibration method for a tri-axial field sensor is based on ellipsoid fitting, which has no requirement for external references. However, the self-calibration based on ellipsoid fitting is unable to determine and compensate the mutual misalignment between different sensors in a multi-sensor system. Therefore, a novel calibration method that employs the invariance of the dot product of two constant vectors is introduced in this paper. The proposed method, which is named dot product invariance method, brings a complete solution for the error model of tri-axial field sensors, and can solve the problem of alignment in a multi-sensor system. Its effectiveness and superiority over the ellipsoid fitting method are illustrated by numerical simulations, and its application on a digital magnetic compass shows significant enhancement of the heading accuracy.

[1]  F. Golnaraghi,et al.  A Triaxial Accelerometer Calibration Method Using a Mathematical Model , 2010, IEEE Transactions on Instrumentation and Measurement.

[2]  Valérie Renaudin,et al.  Complete Triaxis Magnetometer Calibration in the Magnetic Domain , 2010, J. Sensors.

[3]  Suzanne Lesecq,et al.  Calibration methods for inertial and magnetic sensors , 2009 .

[4]  Pavel Ripka,et al.  Errors of AMR compass and methods of their compensation , 2006 .

[5]  Xiao Zhang,et al.  A Novel Calibration Method of Magnetic Compass Based on Ellipsoid Fitting , 2011, IEEE Transactions on Instrumentation and Measurement.

[6]  Naser El-Sheimy,et al.  A new multi-position calibration method for MEMS inertial navigation systems , 2007 .

[7]  Javaan Chahl,et al.  Semiautomatic calibration and alignment of a low cost, 9 sensor inertial magnetic measurement sensor , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[8]  G.H. Elkaim,et al.  Extension of a two-step calibration methodology to include nonorthogonal sensor axes , 2008, IEEE Transactions on Aerospace and Electronic Systems.

[9]  Marko Topič,et al.  Calibration and data fusion solution for the miniature attitude and heading reference system , 2007 .

[10]  Timo Pylvänäinen,et al.  Automatic and adaptive calibration of 3D field sensors , 2008 .

[11]  Demoz Gebre-Egziabher,et al.  Magnetometer Autocalibration Leveraging Measurement Locus Constraints , 2007 .

[12]  Carlos Silvestre,et al.  Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame , 2011, IEEE Transactions on Aerospace and Electronic Systems.

[13]  Andrew Y. C. Nee,et al.  Methods for in-field user calibration of an inertial measurement unit without external equipment , 2008 .

[14]  John G. Griffiths,et al.  Least squares ellipsoid specific fitting , 2004, Geometric Modeling and Processing, 2004. Proceedings.

[15]  John L. Crassidis,et al.  Real-Time Attitude-Independent Three-Axis Magnetometer Calibration , 2005 .

[16]  Muhammad Haris Afzal,et al.  New method for magnetometers based orientation estimation , 2010, IEEE/ION Position, Location and Navigation Symposium.

[17]  Demoz Gebre-Egziabher,et al.  Calibration of Strapdown Magnetometers in Magnetic Field Domain , 2006 .

[18]  Yuanxin Wu,et al.  Improved multi-position calibration for inertial measurement units , 2009 .

[19]  Federico Pedersini,et al.  Autocalibration of MEMS Accelerometers , 2009, IEEE Transactions on Instrumentation and Measurement.