Comparison of Two Commercial Assays with Expert Microscopy for Confirmation of Symptomatically Diagnosed Malaria

ABSTRACT Conventional light microscopy has been the established method for malaria diagnosis. However, recently several nonmicroscopic rapid diagnostic tests have been developed for situations in which reliable microscopy may not be available. This study was conducted to evaluate the diagnostic performance of a recently introduced ICT Malaria Pf/Pv test. This assay detects Plasmodium falciparum histidine-rich protein 2 antigen (PfHRP-2) for P. falciparum diagnosis and pan-malarial antigen for P. vivax diagnosis. In this study we compared the performance of ICT Malaria Pf/Pv with microscopy of Giemsa-stained blood films and with an OptiMAL test that detects Plasmodium lactate dehydrogenase (pLDH) antigen. A total of 750 clinically suspected malaria patients were examined at local health centers in Kuwait. Both the antigen tests had a high degree of specificity (>98%) for detection of malaria infection. However, they were less sensitive than microscopy. Compared with microscopy the ICT Malaria PF/pf test failed to detect malaria infection in 93 (34%) of 271 malaria patients (11% of patients with P. falciparum and 37% of patients with P. vivax) and the OptiMAL test failed to detect malaria infection in 41 (15%) of 271 malaria patients (7% of patients with P. falciparum and 13% of patients with P. vivax). The sensitivities of the ICT Malaria Pf/Pv and OptiMAL tests for detection of P. falciparum infection were 81 and 87%, and those for detecting P. vivax were 58 to 79%, respectively. The sensitivity of the ICT Malaria Pf/Pv and OptiMAL tests decreased significantly to 23 and 44%, respectively, at parasite densities of <500/μl. Both of the tests also produced a number of false-positive results. Overall, the performance of the OptiMAL test was better than that of the ICT Malaria Pf/Pv test. However, our results raise particular concern over the sensitivity of the ICT Malaria Pf/Pv test for detection of P. vivax infection. Further developments appear necessary to improve the performance of the ICT Malaria Pf/Pv test.

[1]  P. Chiodini,et al.  Performance of the OptiMAL malaria antigen capture dipstick for malaria diagnosis and treatment monitoring at the Hospital for Tropical Diseases, London , 2000, British journal of haematology.

[2]  T. Jelínek,et al.  Evaluation of a Dipstick Test for the Rapid Diagnosis of Imported Malaria Among Patients Presenting Within the Network TropNetEurop , 2001, Scandinavian journal of infectious diseases.

[3]  A rapid dipstick antigen capture assay for the diagnosis of falciparum malaria , 1996, Bulletin of the World Health Organization.

[4]  N. Valecha,et al.  Field evaluation of the ICT Malaria P.f/P.v immunochromatographic test for diagnosis of Plasmodium falciparum and P.vivax infection in forest villages of Chhindwara, central India , 2000, Tropical medicine & international health : TM & IH.

[5]  J. Iqbal,et al.  Comparison of the OptiMAL Test with PCR for Diagnosis of Malaria in Immigrants , 1999, Journal of Clinical Microbiology.

[6]  G. Dettori,et al.  Evaluation of OptiMAL Assay test to detect imported malaria in Italy. , 2000, The new microbiologica.

[7]  T. Jelínek,et al.  Use of dipstick tests for the rapid diagnosis of malaria in nonimmune travelers. , 2006, Journal of travel medicine.

[8]  L. Lynen,et al.  Evaluation of two tests based on the detection of histidine rich protein 2 for the diagnosis of imported Plasmodium falciparum malaria. , 1998, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[9]  P Chiodini,et al.  Immunocapture diagnostic assays for malaria using Plasmodium lactate dehydrogenase (pLDH). , 1999, The American journal of tropical medicine and hygiene.

[10]  M. Gatton,et al.  Performance appraisal of rapid on-site malaria diagnosis (ICT malaria Pf/Pv test) in relation to human resources at village level in Myanmar. , 2002, Acta tropica.

[11]  C. Wongsrichanalai,et al.  Comparison of a rapid field immunochromatographic test to expert microscopy for the detection of Plasmodium falciparum asexual parasitemia in Thailand. , 1999, Acta tropica.

[12]  S. Hoffman,et al.  Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assay , 1994, The Lancet.

[13]  F. Nosten,et al.  Short communication: Paracheck‐Pf®: a new, inexpensive and reliable rapid test for P. falciparum malaria , 2001, Tropical medicine & international health : TM & IH.

[14]  J. Karbwang,et al.  ParaSight-F test for the detection of treatment failure in multidrug resistant Plasmodium falciparum malaria. , 1996, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[15]  W. Klaskala,et al.  Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria , 1998, Journal of Clinical Microbiology.

[16]  C. Shiff,et al.  The rapid manual ParaSight-F test. A new diagnostic tool for Plasmodium falciparum infection. , 1993, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[17]  P. Chiodini,et al.  Comparison of a parasite lactate dehydrogenase-based immunochromatographic antigen detection assay (OptiMAL) with microscopy for the detection of malaria parasites in human blood samples. , 1999, The American journal of tropical medicine and hygiene.

[18]  D. Warhurst,et al.  ACP Broadsheet no 148. July 1996. Laboratory diagnosis of malaria. , 1996, Journal of clinical pathology.

[19]  E. Tjitra,et al.  Failure of the 'pan-malarial' antibody of the ICT Malaria P.f/P.v immunochromatographic test to detect symptomatic Plasmodium malariae infection. , 2000, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[20]  C. Shiff,et al.  The ParaSight-F test: a simple rapid manual dipstick test to detect Plasmodium falciparum infection. , 1994, Parasitology today.

[21]  A. Saul,et al.  Disappearance of pan-malarial antigen reactivity using the ICT Malaria P.f/P.v kit parallels decline of patent parasitaemia as shown by microscopy. , 2000, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[22]  J. Iqbal,et al.  Malaria in Non-Endemic Kuwait: Detection of Very Low Level Plasmodium falciparum Infections Using Polymerase Chain Reaction , 1998, Medical Principles and Practice.

[23]  K. Kain,et al.  Parasight F test compared with the polymerase chain reaction and microscopy for the diagnosis of Plasmodium falciparum malaria in travelers. , 1997, The American journal of tropical medicine and hygiene.

[24]  C. Shiff,et al.  The ParaSightR-F test: A simple rapid manual dipstick test to detect Plasmodium falciparum infection , 1994 .

[25]  J. Iqbal,et al.  Diagnosis of imported malaria by Plasmodium lactate dehydrogenase (pLDH) and histidine-rich protein 2 (PfHRP-2)-based immunocapture assays. , 2001, The American journal of tropical medicine and hygiene.

[26]  D. Durrheim,et al.  Accuracy of a rapid immunochromatographic card test for Plasmodium falciparum in a malaria control programme in South Africa. , 1998, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[27]  S. Hewitt,et al.  Comparison of three antigen detection methods for diagnosis and therapeutic monitoring of malaria: a field study from southern Vietnam , 2002, Tropical medicine & international health : TM & IH.

[28]  Purnomo,et al.  Performance of the OptiMAL assay for detection and identification of malaria infections in asymptomatic residents of Irian Jaya, Indonesia. , 2000, The American journal of tropical medicine and hygiene.

[29]  A. Moody Rapid Diagnostic Tests for Malaria Parasites , 2002, Clinical Microbiology Reviews.

[30]  V. Sharma,et al.  Malaria diagnosis by field workers using an immunochromatographic test. , 1997, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[31]  M. Molyneux,et al.  Diagnosis and treatment of malaria in Britain. , 1993, BMJ.