Disturbance Observer-Based Hybrid Control of Displacement and Force in a Medical Tele-Analyzer

This paper presents hybrid control of displacement and force in a Medical Tele- Analyzer by disturbance observer-based controller which is robust to internal and external disturbances; model uncertainty, load, and friction for instances. The developed Medical Tele- Analyzer consists of 2 subsystems; doctor-side subsystem and patient-side subsystem. In the doctor side subsystem, an array of displacement sensor is equipped to detect movement of doctor's hand and fingers. The detected information is transmitted to the patient side to be used in medical analysis. On the other hand, the patient-side subsystem consists of an array of displacement actuators, which is used to follow displacement of doctor's hand and fingers. An array of force sensors is used to detect forces between patient and the equipment. Since displacement control in patient side is coupled with force control in doctor side and vice-versa, design of the controller has to take into account this coupling. Not only using in medical tele- analysis, the proposed system can also be used in any tele-displacement-force controls of industrial processes.

[1]  C Baur,et al.  VIRGY: a virtual reality and force feedback based endoscopic surgery simulator. , 1998, Studies in health technology and informatics.

[2]  A. Suebsomran,et al.  Disturbance observer-based hybrid control of displacement and force in medical tele-analyzer for abdominal mass analysis , 2002, 2002 IEEE International Conference on Industrial Technology, 2002. IEEE ICIT '02..

[3]  Kouhei Ohnishi Robust Motion Control by Disturbance Observer , 1996, J. Robotics Mechatronics.

[4]  M. Parnichkun,et al.  Development of a force-displacement controlled medical tele-analyzer , 2001, ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570).

[5]  Guosheng Wang,et al.  Reconfiguring Second-order Dynamic Systems via P-D Feedback Eigenstructure Assignment : A Parametric Method , 2005 .

[6]  J. R. Boston,et al.  An Investigation of the Pump Operating Characteristics as a Novel Control Index for LVAD Control , 2005 .

[7]  A C Dumay,et al.  Medicine in virtual environments. , 1995, Technology and health care : official journal of the European Society for Engineering and Medicine.

[8]  Leon D. Harmon,et al.  Automated Tactile Sensing , 1982 .

[9]  J. Y. S. Luh,et al.  Joint torque control by a direct feedback for industrial robots , 1983 .

[10]  J. S. Luh,et al.  Joint torque control by a direct feedback for industrial robots , 1981, 1981 20th IEEE Conference on Decision and Control including the Symposium on Adaptive Processes.