Opportunities and Precautions in Measurement of Power Loss in Electrical Steel Laminations Using the Initial Rate of Rise of Temperature Method

A system has been developed for measuring localized power loss of electrical steel laminations based on the initial rate of rise of temperature method. Hardware and software components were designed and developed individually to make an accurate measuring system. Three experiments were carried out to calibrate the system and quantify its accuracy over a wide measurement range. The application of the measuring system was demonstrated in two cases of measuring localized power losses near bolt holes in laminations and near artificial lamination edge burrs in a 300 kVA, 3 phase transformer core. The experimental results show that the developed system can measure localized power loss over a wide range with uncertainty of measurement less than ± 2%, but precautions are necessary when interpreting measurements in regions where the magnitude of the loss varies significantly over distances of less than a few centimeters.

[1]  D. Roger,et al.  Experimental Characterization of Interlamination Shorts in Transformer Cores , 2010, IEEE Transactions on Magnetics.

[2]  D. A. Ball,et al.  An improved thermometric method of measuring local power dissipation , 1965 .

[3]  Anthony John Moses,et al.  Power loss and flux density distributions in the T-joint of a three phase transformer core , 1972 .

[4]  A. J. Gilbert,et al.  A method of measuring loss distribution in electrical machines , 1961 .

[5]  P. Marketos,et al.  Effect of Artificial Burrs on the Total Power Loss of a Three-Phase Transformer Core , 2010, IEEE Transactions on Magnetics.

[6]  Anthony John Moses,et al.  The spatial variation of localized power loss in two practical transformer T-joints , 1973 .

[7]  Sang Bin Lee,et al.  An advanced technique for detecting inter-laminar stator core faults in large electric machines , 2005, IEEE Transactions on Industry Applications.

[8]  D.M. Ionel,et al.  Computation of Core Losses in Electrical Machines Using Improved Models for Laminated Steel , 2006, IEEE Transactions on Industry Applications.

[9]  A. Moses,et al.  Localised losses in stator laminations of an induction motor under PWM excitation , 2005 .

[10]  Anthony John Moses,et al.  An intercomparison of rotational loss measurements in non oriented Fe-Si alloys , 2008 .

[11]  Fausto Fiorillo,et al.  Comprehensive investigation of alternating and rotational losses in non-oriented steel sheets , 2009 .

[12]  A. Moses,et al.  Apparatus for experimental simulation of magnetic flux and power loss distribution in a turbogenerator stator core , 1981 .

[13]  Anthony John Moses,et al.  Power loss of non oriented electrical steel under square wave excitation , 2001 .

[14]  C. M. Laffoon,et al.  Additional Losses of Synchronous Machines , 1927, Transactions of the American Institute of Electrical Engineers.

[15]  R. S. Girgis,et al.  Experimental investigations on effect of core production attributes on transformer core loss performance , 1998 .

[16]  A. Moses,et al.  Flux distribution and power loss in the mitered overlap joint in power transformer cores , 1973 .

[17]  A. Moses,et al.  Comparison of the localized power loss and flux distribution in the butt and lap and mitred overlap corner configurations , 1974 .

[18]  L. Rosenhead Conduction of Heat in Solids , 1947, Nature.

[20]  K. A. Hempel,et al.  Power loss in electrical steel under elliptically rotating flux conditions , 1996 .