Evaluation of linear accelerator performance standards using an outcome oriented approach.

Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest.

[1]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[2]  J. Simard,et al.  Concomitant GRID boost for Gamma Knife radiosurgery. , 2005, Medical physics.

[3]  R. Mohan,et al.  Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose. , 2002, International journal of radiation oncology, biology, physics.

[4]  M Engelsman,et al.  The effect of breathing and set-up errors on the cumulative dose to a lung tumor. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  William Y. Song,et al.  Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty , 2005, Physics in medicine and biology.

[6]  Radhe Mohan,et al.  Dose sculpting with generalized equivalent uniform dose. , 2005, Medical physics.

[7]  M. Kan,et al.  A new dose-volume-based Plan Quality Index for IMRT plan comparison. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  G. Flux,et al.  The use of BED and EUD concepts in heterogeneous radioactivity distributions on a multicellular scale for targeted radionuclide therapy. , 2007, Cancer biotherapy & radiopharmaceuticals.

[9]  Marcel van Herk,et al.  The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms. , 2002, Medical physics.

[10]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[11]  R. Stewart,et al.  Designing equivalent treatment regimens for prostate radiotherapy based on equivalent uniform dose. , 2008, The British journal of radiology.

[12]  On the parameter describing the generalised equivalent uniform dose (gEUD) for tumours. , 2007, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[13]  X. Li,et al.  Comparison of three accelerated partial breast irradiation techniques: treatment effectiveness based upon biological models. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  Jan Seuntjens,et al.  Development of quality control standards for radiation therapy equipment in Canada , 2007, Journal of applied clinical medical physics.

[15]  T. Bortfeld,et al.  From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning. , 2003, Medical physics.