Design and Evaluation of a Robotic Device for Automated Tail Vein Cannulations in Rodent Models.

Preclinical testing in rodent models is a ubiquitous part of modern biomedical research and commonly involves accessing the venous bloodstream for blood sampling and drug delivery. Manual tail vein cannulation is a time-consuming process and requires significant skill and training, particularly since improperly inserted needles can affect the experimental results and study outcomes. In this paper, we present a miniaturized, robotic medical device for automated, image-guided tail vein cannulations in rodent models. The device is composed of an actuated three degrees-of-freedom (DOFs) needle manipulator, three-dimensional (3D) near-infrared (NIR) stereo cameras, and an animal holding platform. Evaluating the system through a series of workspace simulations and free-space positioning tests, the device exhibited a sufficient work volume for the needle insertion task and submillimeter accuracy over the calibration targets. The results indicate that the device is capable of cannulating tail veins in rodent models as small as 0.3 mm in diameter, the smallest diameter vein required to target.

[1]  A. C. Burton,et al.  THE TAIL OF THE RAT, IN TEMPERATURE REGULATION AND ACCLIMATIZATION. , 1965, Canadian journal of physiology and pharmacology.

[2]  Tsu-Chin Tsao,et al.  An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback , 2015, IEEE/ASME Transactions on Mechatronics.

[3]  K. Michi,et al.  An anatomical study on the forearm vascular system. , 1996, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[4]  Martin L. Yarmush,et al.  3D Near Infrared and Ultrasound Imaging of Peripheral Blood Vessels for Real-Time Localization and Needle Guidance , 2016, MICCAI.

[5]  Aaron Fenster,et al.  REGISTRATION OF THREE-DIMENSIONAL HIGH-FREQUENCY ULTRASOUND IMAGES TO A ROBOTIC NEEDLE-POSITIONING SYSTEM FOR PRE-CLINICAL RESEARCH , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[6]  Kenichi Nomoto,et al.  Antitumor Effect of a Splenic Injection of 5-Fluorouracil on Metastatic Liver Cancer in Mice , 2004, Journal of Pharmacology and Experimental Therapeutics.

[7]  C. Gordon Influence of heating rate on control of heat loss from the tail in mice. , 1983, The American journal of physiology.

[8]  Jacques Gangloff,et al.  An image-guided robot for needle insertion in small animal. Accurate needle positioning using visual servoing. , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[9]  Peter Kazanzides,et al.  Development of an image-guided robot for small animal research , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[10]  E. Groman,et al.  Method to quantify tail vein injection technique in small animals. , 2004, Contemporary topics in laboratory animal science.

[11]  D Malakoff,et al.  The Rise of the Mouse, Biomedicine's Model Mammal , 2000, Science.

[12]  Brittany Nan Berry-Pusey A vascular access system (VAS) for preclinical models , 2012 .

[13]  Yerem Yeghiazarians,et al.  Closed-chest cell injections into mouse myocardium guided by high-resolution echocardiography. , 2005, American journal of physiology. Heart and circulatory physiology.

[14]  Hagen Gasse,et al.  Blood vessels of the rat tail: a histological re-examination with respect to blood vessel puncture methods , 2003, Laboratory animals.

[15]  Jatinder Singh,et al.  The national centre for the replacement, refinement, and reduction of animals in research , 2012, Journal of pharmacology & pharmacotherapeutics.

[16]  R. Taschereau,et al.  A semi-automated vascular access system for preclinical models , 2013, Physics in medicine and biology.

[17]  Steve D. M. Brown,et al.  A systematic, genome-wide, phenotype-driven mutagenesis programme for gene function studies in the mouse , 2000, Nature Genetics.

[18]  Janne Heikkilä,et al.  Geometric Camera Calibration Using Circular Control Points , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[19]  Martin L. Yarmush,et al.  Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance , 2017, IEEE Transactions on Industrial Electronics.

[20]  Aaron Fenster,et al.  Design, calibration and evaluation of a robotic needle-positioning system for small animal imaging applications , 2007, Physics in medicine and biology.

[21]  M. Cenk Cavusoglu,et al.  Regular Paper Submission for the Ieee Transactions on Mechatronics Design of a Parallel Robot for Needle Based Interventions on Small Animals¨ozkan , 2022 .