Evidence that the gonococcal porA pseudogene is present in a broad range of Neisseria gonorrhoeae strains; suitability as a diagnostic target

Aims: The primary aim of the study was to determine if the gonococcal porA pseudogene is a stable sequence target for the detection of Neisseria gonorrhoeae by PCR. Methods: A total of 240 gonococcal strains from various geographic locations were tested by porA pseudogene PCR. In addition, porA pseudogene PCR positivity rates were compared with established gonococcal assays in three Australian states. Results: All N. gonorrhoeae isolates provided positive results in the porA pseudogene PCR. Positivity rates compared favourably with established gonococcal assays, with increased N. gonorrhoeae detection in the Northern Territory and Western Australia. Conclusions: The results of this multicentre study provide further evidence that the porA pseudogene is highly conserved across a diverse range N. gonorrhoeae strains and is a suitable PCR target for routine detection of N. gonorrhoeae.

[1]  D. Whiley,et al.  Nucleic acid amplification testing for Neisseria gonorrhoeae: an ongoing challenge. , 2006, The Journal of molecular diagnostics : JMD.

[2]  S. Garland,et al.  A cluster of culture positive gonococcal infections but with false negative cppB gene based PCR , 2005, Sexually Transmitted Infections.

[3]  M. Unemo,et al.  The porA pseudogene of Neisseria gonorrhoeae– low level of genetic polymorphism and a few, mainly identical, inactivating mutations , 2005, APMIS : acta pathologica, microbiologica, et immunologica Scandinavica.

[4]  J. Bates,et al.  A real-time PCR assay for the detection of Neisseria gonorrhoeae in genital and extragenital specimens. , 2005, Diagnostic microbiology and infectious disease.

[5]  B. Duim,et al.  Multicenter Validation of the cppB Gene as a PCR Target for Detection of Neisseria gonorrhoeae , 2004, Journal of Clinical Microbiology.

[6]  J. Bates,et al.  A new confirmatory Neisseria gonorrhoeae real-time PCR assay targeting the porA pseudogene , 2004, European Journal of Clinical Microbiology and Infectious Diseases.

[7]  S. Garland,et al.  Evaluation of real time polymerase chain reaction assays for confirmation of Neisseria gonorrhoeae in clinical samples tested positive in the Roche Cobas Amplicor assay , 2004, Sexually Transmitted Infections.

[8]  Eric P. Skaar,et al.  Recombination, repair and replication in the pathogenic Neisseriae: the 3 R′s of molecular genetics of two human‐specific bacterial pathogens , 2003, Molecular microbiology.

[9]  H. Mallinson,et al.  Evaluation of the Specificities of Five DNA Amplification Methods for the Detection of Neisseria gonorrhoeae , 2003, Journal of Clinical Microbiology.

[10]  J. Fyfe,et al.  An assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types. , 2003, Communicable diseases intelligence quarterly report.

[11]  Robert E. Johnson,et al.  Screening tests to detect Chlamydia trachomatis and Neisseria gonorrhoeae infections -- 2002 , 2002 .

[12]  D. Whiley,et al.  A real-time PCR assay for the detection of Neisseria gonorrhoeae by LightCycler. , 2002, Diagnostic microbiology and infectious disease.

[13]  D. Farrell Evaluation of AMPLICOR Neisseria gonorrhoeae PCR Using cppB Nested PCR and 16S rRNA PCR , 1999, Journal of Clinical Microbiology.

[14]  T. Meyer,et al.  Genome plasticity in Neisseria gonorrhoeae. , 1996, FEMS microbiology letters.