Intradermal Insulin Delivery

The incidence of insulinopenic diabetes mellitus is constantly increasing, and in addition, approximately a third of all hyperinsulinemic diabetic patients develop insulinopenia. Optimal glycemic control is essential to minimize the risk for diabetes-induced complications, but the majority of diabetic patients fail to achieve proper long-term glucose levels even in clinical trials, and even more so in clinical practice. Compliance with a treatment regimen is likely to be higher if the procedure is simple, painless, and discreet. Thus, insulin has been suggested for nasal, gastrointestinal, and inhalation therapy, but so far with considerable downsides in effect, side effects, or patient acceptance. The stratum corneum is the main barrier preventing convenient drug administration without the drawbacks of subcutaneous injections. Recently, devices with miniaturized needles have been developed that combine the simplicity and discretion of patch-based treatments, but with the potential of peptide and protein administration. As this review describes, initial comparisons with subcutaneous administration now suggest microneedle patches for active insulin delivery are efficient in maintaining glycemic control. Hollow microneedle technology could also prove to be efficient in systemic as well as local delivery of other macromolecular drugs, such as vaccines.

[1]  J. Saaddine,et al.  Achievement of goals in U.S. diabetes care, 1999-2010. , 2013, The New England journal of medicine.

[2]  P. Wiffen ENHANCED GLUCOSE CONTROL FOR PREVENTING AND TREATING DIABETIC NEUROPATHY , 2012 .

[3]  A. Vaag,et al.  Intensive glycaemic control for patients with type 2 diabetes: systematic review with meta-analysis and trial sequential analysis of randomised clinical trials , 2011, BMJ : British Medical Journal.

[4]  F. Gueyffier,et al.  Effect of intensive glucose lowering treatment on all cause mortality, cardiovascular death, and microvascular events in type 2 diabetes: meta-analysis of randomised controlled trials , 2011, BMJ : British Medical Journal.

[5]  P. Nilsson,et al.  Glycemic Control and Cardiovascular Disease in 7,454 Patients With Type 1 Diabetes , 2010, Diabetes Care.

[6]  N. Sattar,et al.  Effect of intensive control of glucose on cardiovascular outcomes and death in patients with diabetes mellitus: a meta-analysis of randomised controlled trials , 2009, The Lancet.

[7]  Mark R. Prausnitz,et al.  Effect of Microneedle Design on Pain in Human Volunteers , 2008, The Clinical journal of pain.

[8]  Göran Stemme,et al.  Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion , 2008, IEEE Transactions on Biomedical Engineering.

[9]  Y Mano,et al.  Painless self-monitoring of blood glucose at finger sites. , 2008, Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association.

[10]  Göran Stemme,et al.  Novel Microneedle Patches for Active Insulin Delivery are Efficient in Maintaining Glycaemic Control: An Initial Comparison with Subcutaneous Administration , 2007, Pharmaceutical Research.

[11]  Niclas Roxhed,et al.  A Fully Integrated Microneedle-based Transdermal Drug Delivery System , 2007 .

[12]  N. Roxhed,et al.  Compact, Seamless Integration of Active Dosing and Actuation with Microneedles for Transdermal Drug Delivery , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.

[13]  Mark R Prausnitz,et al.  Precise microinjection into skin using hollow microneedles. , 2006, The Journal of investigative dermatology.

[14]  Sion A. Coulman,et al.  Minimally invasive cutaneous delivery of macromolecules and plasmid DNA via microneedles. , 2006, Current drug delivery.

[15]  Skin Penetration of Silicon Dioxide Microneedle Arrays , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Wijaya Martanto,et al.  Microinfusion Using Hollow Microneedles , 2006, Pharmaceutical Research.

[17]  Gregory W. Sluggett,et al.  EXUBERA: pharmaceutical development of a novel product for pulmonary delivery of insulin. , 2005, Diabetes technology & therapeutics.

[18]  Rupak K Banerjee,et al.  Evaluation of coupled convective-diffusive transport of drugs administered by intravitreal injection and controlled release implant. , 2005, Journal of controlled release : official journal of the Controlled Release Society.

[19]  T. Mandal,et al.  Inhaled insulin for diabetes mellitus. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[20]  G. Stemme,et al.  Reliable in-vivo penetration and transdermal injection using ultra-sharp hollow microneedles , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[21]  S. Dinh,et al.  Response of the lung to pulmonary insulin dosing in the rat model and effects of changes in formulation. , 2005, Diabetes technology & therapeutics.

[22]  Dorian Liepmann,et al.  Clinical microneedle injection of methyl nicotinate: stratum corneum penetration , 2005, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[23]  Mark G. Allen,et al.  Hollow metal microneedles for insulin delivery to diabetic rats , 2005, IEEE Transactions on Biomedical Engineering.

[24]  Mark R Prausnitz,et al.  Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles. , 2005, Diabetes technology & therapeutics.

[25]  L. Niskanen,et al.  FlexPen: addressing issues of confidence and convenience in insulin delivery. , 2005, Clinical therapeutics.

[26]  S. D. Collins,et al.  Microneedle array for transdermal biological fluid extraction and in situ analysis , 2004 .

[27]  M. Davies,et al.  The reality of glycaemic control in insulin treated diabetes: defining the clinical challenges , 2004, International Journal of Obesity.

[28]  Mark R Prausnitz,et al.  Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force. , 2004, Journal of biomechanics.

[29]  Mahmoud Ameri,et al.  Transdermal delivery of desmopressin using a coated microneedle array patch system. , 2004, Journal of controlled release : official journal of the Controlled Release Society.

[30]  Wijaya Martanto,et al.  Transdermal Delivery of Insulin Using Microneedles in Vivo , 2004, Pharmaceutical Research.

[31]  M. Stumvoll,et al.  [Skin changes in diabetes mellitus]. , 2004, Der Hautarzt; Zeitschrift fur Dermatologie, Venerologie, und verwandte Gebiete.

[32]  R. Szeimies,et al.  Hautveränderungen bei Diabetes mellitus , 2004, Der Hautarzt.

[33]  A. Barnett Exubera inhaled insulin: a review , 2004, International journal of clinical practice.

[34]  M. Cormier,et al.  Transdermal Delivery of Antisense Oligonucleotides with Microprojection Patch (macroflux®) Technology , 2001, Pharmaceutical Research.

[35]  J. Matriano,et al.  Macroflux® Microprojection Array Patch Technology: A New and Efficient Approach for Intracutaneous Immunization , 2004, Pharmaceutical Research.

[36]  Mark G. Allen,et al.  Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[37]  B. Zinman,et al.  Alternative routes of insulin delivery , 2003, Diabetic medicine : a journal of the British Diabetic Association.

[38]  M. Korytkowski,et al.  A multicenter, randomized, open-label, comparative, two-period crossover trial of preference, efficacy, and safety profiles of a prefilled, disposable pen and conventional vial/syringe for insulin injection in patients with type 1 or 2 diabetes mellitus. , 2003, Clinical therapeutics.

[39]  Göran Stemme,et al.  Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer , 2003 .

[40]  Diane E. Sutter,et al.  Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery , 2002, Nature Medicine.

[41]  M. Allen,et al.  Lack of Pain Associated with Microfabricated Microneedles , 2001, Anesthesia and analgesia.

[42]  W H Smart,et al.  The use of silicon microfabrication technology in painless blood glucose monitoring. , 2000, Diabetes technology & therapeutics.

[43]  L. Norlén The skin barrier : structure and physical function , 1999 .

[44]  Henry,et al.  Microfabricated microneedles: A novel approach to transdermal drug delivery , 1999, Journal of pharmaceutical sciences.

[45]  A. Johansen,et al.  Cutis/subcutis thickness at insulin injection sites and localization of simulated insulin boluses in children with Type 1 diabetes mellitus: need for individualization of injection technique? , 1998, Diabetic medicine : a journal of the British Diabetic Association.

[46]  D. Rogers,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus , 1994 .

[47]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.