The Use of Filtering Methods to Compensate for Constant Attenuation in Single-Photon Emission Computed Tomography

A back projection of filtered projection (BKFIL) reconstruction algorithm is presented that is applicable to single-photon emission computed tomography (ECT) in the presence of a constant attenuating medium such as the brain. The filters used in transmission computed tomography (TCT)-comprised of a ramp multiplied by window functions¿are modified so that the single-photon ECT filter is a function of the constant attenuation coefficient. The filters give good reconstruction results with sufficient angular and lateral sampling. With continuous samples the BKFIL algorithm has a point spread function that is the Hankel transform of the window function. The resolution and statistical properties of the filters are demonstrated by various simulations which assume an ideal detector response. Statistical formulas for the reconstructed image show that the square of the percent-root-mean-square (percent-rms) uncertainty of the reconstruction is inversely proportional to the total measured counts. The results indicate that constant attenuation can be compensated for by using an attenuation-dependent filter that reconstructs the transverse section reliably. Computer time requirements are two times that of conventional TCT or positron ECT and there is no increase in memory requirements.

[1]  T. Budinger,et al.  Three-dimensional reconstruction in nuclear medicine emission imaging , 1974 .

[2]  G. N. Ramachandran,et al.  Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms. , 1971, Proceedings of the National Academy of Sciences of the United States of America.

[3]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[4]  S J Riederer,et al.  Ripple suppression during reconstruction in transverse tomography. , 1975, Physics in medicine and biology.

[5]  Ernest T. Tsui,et al.  A Stochastic Filter for Transverse Section Reconstruction , 1979, IEEE Transactions on Nuclear Science.

[6]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[7]  T A Iinuma,et al.  Correction functions and statistical noises in transverse section picture reconstruction. , 1976, Computers in biology and medicine.

[8]  A. C. Kak,et al.  ALIASING ARTIFACTS IN COMPUTERIZED TOMOGRAPHY , 1980 .

[9]  J J de Lima,et al.  [Emission computed tomography]. , 1980, Acta medica portuguesa.

[10]  C. Metz,et al.  The exponential Radon transform , 1980 .

[11]  H H Barrett,et al.  Statistical limitations in transaxial tomography. , 1976, Computers in biology and medicine.

[12]  S. Bellini,et al.  Compensation of tissue absorption in emission tomography , 1979 .

[13]  J. Kruskal,et al.  COMPUTERIZED TOMOGRAPHY: THE NEW MEDICAL X-RAY TECHNOLOGY , 1978 .

[14]  A. C. Riddle,et al.  Inversion of Fan-Beam Scans in Radio Astronomy , 1967 .

[15]  M. Ter-pogossian,et al.  Basic principles of computed axial tomography. , 1977, Seminars in nuclear medicine.