Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency

Objective To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. Materials and Methods Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups. Results No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm3 vs. 20.8 ± 10.7 cm3; p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29). Conclusion Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time.

[1]  R. Lencioni Loco‐regional treatment of hepatocellular carcinoma , 2010, Hepatology.

[2]  B. Choi,et al.  Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers , 2013, Korean journal of radiology.

[3]  Jeong Min Lee,et al.  Multiple-electrode radiofrequency ablations using Octopus® electrodes in an in vivo porcine liver model. , 2012, The British journal of radiology.

[4]  S. Mulier,et al.  A review of the general aspects of radiofrequency ablation , 2005, Abdominal Imaging.

[5]  Jae Young Lee,et al.  Percutaneous Radiofrequency Ablation with Multiple Electrodes for Medium-Sized Hepatocellular Carcinomas , 2011, Korean journal of radiology.

[6]  Christopher L Brace,et al.  Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results. , 2006, Radiology.

[7]  L. Solmi,et al.  Therapeutic effectiveness of echo-guided percutaneous radiofrequency ablation therapy with a LeVeen needle electrode in hepatocellular carcinoma. , 2006, World journal of gastroenterology.

[8]  Eun Sun Lee,et al.  Evaluation of the In Vivo Efficiency and Safety of Hepatic Radiofrequency Ablation Using a 15-G Octopus® in Pig Liver , 2013, Korean journal of radiology.

[9]  V. Mazzaferro,et al.  EASL-EORTC Clinical Practice Guidelines: Management of hepatocellular carcinoma European Association for the Study of the Liver ⇑ , European Organisation for Research and Treatment of Cancer , 2012 .

[10]  M. Dumont,et al.  European Association for the Study of the Liver , 1971 .

[11]  D. Haemmerich,et al.  Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model. , 2005, Journal of vascular and interventional radiology : JVIR.

[12]  Jae Young Lee,et al.  Hepatic Radiofrequency Ablation Using Multiple Probes: Ex Vivo and In Vivo Comparative Studies of Monopolar versus Multipolar Modes , 2006, Korean journal of radiology.

[13]  T. Winter,et al.  Multiple-electrode radiofrequency ablation: comparison with a conventional cluster electrode in an in vivo porcine kidney model. , 2007, Journal of vascular and interventional radiology : JVIR.

[14]  G. Dodd,et al.  Radiofrequency thermal ablation: computer analysis of the size of the thermal injury created by overlapping ablations. , 2001, AJR. American journal of roentgenology.

[15]  Jae Young Lee,et al.  Radiofrequency ablation of the porcine liver in vivo: increased coagulation with an internally cooled perfusion electrode. , 2006, Academic radiology.

[16]  L. Mariani,et al.  Radiofrequency Ablation of Small Hepatocellular Carcinoma in Cirrhotic Patients Awaiting Liver Transplantation: A Prospective Study , 2004, Annals of surgery.

[17]  K. Baldwin,et al.  Bipolar radiofrequency ablation of liver tumors: Technical experience and interval follow‐up in 22 patients with 33 ablations , 2012, Journal of surgical oncology.

[18]  S. Goldberg,et al.  Algorithm optimization for multitined radiofrequency ablation: comparative study in ex vivo and in vivo bovine liver. , 2010, Radiology.

[19]  Ming Shi,et al.  Radiofrequency ablation versus hepatic resection for the treatment of hepatocellular carcinomas 2 cm or smaller: a retrospective comparative study. , 2012, Radiology.

[20]  Luigi Solbiati,et al.  Sustained complete response and complications rates after radiofrequency ablation of very early hepatocellular carcinoma in cirrhosis: Is resection still the treatment of choice? , 2007, Hepatology.

[21]  Jeong Min Lee,et al.  MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages , 2001, Korean journal of radiology.

[22]  Thomas Albrecht,et al.  Multipolar radiofrequency ablation of hepatic tumors: initial experience. , 2005, Radiology.

[23]  M. Pompili,et al.  Long-term effectiveness of resection and radiofrequency ablation for single hepatocellular carcinoma ≤3 cm. Results of a multicenter Italian survey. , 2013, Journal of hepatology.

[24]  Rüdiger Hoffmann,et al.  Multipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: correlation between volume of coagulation and amount of applied energy. , 2012, European journal of radiology.

[25]  Jae Young Lee,et al.  Small- and medium-sized hepatocellular carcinomas: monopolar radiofrequency ablation with a multiple-electrode switching system-mid-term results. , 2013, Radiology.

[26]  Joon Koo Han,et al.  Bipolar radiofrequency ablation using wet-cooled electrodes: an in vitro experimental study in bovine liver. , 2005, AJR. American journal of roentgenology.

[27]  Dieter Haemmerich,et al.  Multiple probe radiofrequency ablation: pilot study in an animal model. , 2003, Journal of vascular and interventional radiology : JVIR.

[28]  Young Hun Choi,et al.  Switching Monopolar Radiofrequency Ablation Technique Using Multiple, Internally Cooled Electrodes and a Multichannel Generator: Ex Vivo and In Vivo Pilot Study , 2007, Investigative radiology.

[29]  G. Gazelle,et al.  Hepatocellular carcinoma: radio-frequency ablation of medium and large lesions. , 2000, Radiology.

[30]  Laura Crocetti,et al.  Percutaneous image-guided radiofrequency ablation of liver tumors , 2009, Abdominal Imaging.

[31]  D. Woodfield Hepatocellular carcinoma. , 1986, The New Zealand medical journal.

[32]  D. Ota,et al.  Radiofrequency ablation of liver tumors: influence of technique and tumor size. , 2002, Surgery.

[33]  Wei Yang,et al.  Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients--mathematic model, overlapping mode, and electrode placement process. , 2004, Radiology.

[34]  J. Llovet,et al.  Systematic review: evidence‐based management of hepatocellular carcinoma – an updated analysis of randomized controlled trials , 2006, Alimentary pharmacology & therapeutics.

[35]  H. Rhim,et al.  Systematic review of randomized trials for hepatocellular carcinoma treated with percutaneous ablation therapies , 2009, Hepatology.

[36]  T. Kawabe,et al.  A randomized controlled trial of radiofrequency ablation with ethanol injection for small hepatocellular carcinoma. , 2005, Gastroenterology.

[37]  Guy Marchal,et al.  Electrodes and multiple electrode systems for radio frequency ablation: a proposal for updated terminology. , 2006, Advances in experimental medicine and biology.

[38]  N. Toyota,et al.  Percutaneous radiofrequency ablation as first‐line treatment for small hepatocellular carcinoma: Results and prognostic factors on long‐term follow up , 2010, Journal of gastroenterology and hepatology.

[39]  Riccardo Lencioni,et al.  EASL-EORTC clinical practice guidelines: management of hepatocellular carcinoma. , 2012, Journal of hepatology.

[40]  Joon Koo Han,et al.  Multiple-Electrode Radiofrequency Ablation of In Vivo Porcine Liver: Comparative Studies of Consecutive Monopolar, Switching Monopolar Versus Multipolar Modes , 2007, Investigative radiology.