Disinfection effect of pulsed xenon ultraviolet irradiation on SARS-CoV-2 and implications for environmental risk of COVID-19 transmission

Prolonged survival of SARS-CoV-2 on environmental surfaces and personal protective equipment (PPE) may lead to these surfaces transmitting disease to others. This article reports the effectiveness of a pulsed xenon ultraviolet (PX-UV) disinfection system in reducing the load of SARS-CoV-2 on hard surfaces and N95 respirators. Chamber slides and N95 respirator material were directly inoculated with SARS-CoV-2 and exposed to different durations of PX-UV disinfection. For hard surfaces, disinfection for 1, 2, and 5 minutes resulted in 3.53 Log10, >4.54 Log10, and >4.12 Log10 reductions in viral load, respectively. For N95 respirators, disinfection for 5 minutes resulted in >4.79 Log10 reduction in viral load. We found that PX-UV significantly reduces SARS-CoV-2 on hard surfaces and N95 respirators. With the potential to rapidly disinfectant environmental surfaces and N95 respirators, PX-UV devices are a promising technology for the reduction of environmental and PPE bioburden and to enhance both HCW and patient safety by reducing the risk of exposure to SARS-CoV-2.

[1]  M. Luo,et al.  Asymptomatic SARS‐CoV‐2 infected case with viral detection positive in stool but negative in nasopharyngeal samples lasts for 42 days , 2020, Journal of medical virology.

[2]  Kari Stefansson,et al.  Spread of SARS-CoV-2 in the Icelandic Population , 2020, The New England journal of medicine.

[3]  B. Liu,et al.  Aerosol and Surface Distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospital Wards, Wuhan, China, 2020 , 2020, Emerging infectious diseases.

[4]  Anna M. Acosta,et al.  Public Health Responses to COVID-19 Outbreaks on Cruise Ships — Worldwide, February–March 2020 , 2020, MMWR. Morbidity and mortality weekly report.

[5]  M. J. Broadhurst,et al.  Transmission Potential of SARS-CoV-2 in Viral Shedding Observed at the University of Nebraska Medical Center , 2020, medRxiv.

[6]  Dylan H. Morris,et al.  Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 , 2020, The New England journal of medicine.

[7]  Jianping Huang,et al.  Indirect Virus Transmission in Cluster of COVID-19 Cases, Wenzhou, China, 2020 , 2020, Emerging infectious diseases.

[8]  James O. Lloyd-Smith,et al.  Aerosol and surface stability of HCoV-19 (SARS-CoV-2) compared to SARS-CoV-1 , 2020, medRxiv.

[9]  Oon Tek Ng,et al.  Air, Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) From a Symptomatic Patient. , 2020, JAMA.

[10]  Bing Han,et al.  COVID-19: Gastrointestinal Manifestations and Potential Fecal–Oral Transmission , 2020, Gastroenterology.

[11]  H. Shan,et al.  Evidence for Gastrointestinal Infection of SARS-CoV-2 , 2020, Gastroenterology.

[12]  Jean E. Barth,et al.  A trial of pulsed xenon ultraviolet disinfection to reduce Clostridioides difficile infection , 2019, American journal of infection control.

[13]  R. Olmsted,et al.  Germicidal irradiation of portable medical equipment: Mitigating microbes and improving the margin of safety using a novel, point of care, germicidal disinfection pod. , 2019, American journal of infection control.

[14]  R. Whitworth,et al.  Interaction of healthcare worker hands and portable medical equipment: a sequence analysis to show potential transmission opportunities , 2017, BMC Infectious Diseases.

[15]  C. Donskey,et al.  Contaminated Portable Equipment Is a Potential Vector for Dissemination of Pathogens in the Intensive Care Unit , 2017, Infection Control & Hospital Epidemiology.

[16]  T. Wong,et al.  Role of fomites in SARS transmission during the largest hospital outbreak in Hong Kong , 2017, PloS one.

[17]  Y. Arabi,et al.  Middle East respiratory syndrome coronavirus on inanimate surfaces: A risk for health care transmission , 2016, American Journal of Infection Control.

[18]  D. J. Weber,et al.  Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination☆ , 2015, Journal of Hospital Infection.

[19]  K. Linden,et al.  Action spectra for validation of pathogen disinfection in medium-pressure ultraviolet (UV) systems. , 2015, Water research.

[20]  S. Dusza,et al.  Implementation and impact of ultraviolet environmental disinfection in an acute care setting. , 2014, American journal of infection control.

[21]  Joanne Levin,et al.  The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital. , 2013, American journal of infection control.

[22]  J. Stachowiak,et al.  Impact of a multi-hospital intervention utilising screening, hand hygiene education and pulsed xenon ultraviolet (PX-UV) on the rate of hospital associated meticillin resistant Staphylococcus aureus infection , 2013 .

[23]  W. Kowalski Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection , 2009 .

[24]  Wladyslaw Kowalski,et al.  Ultraviolet Germicidal Irradiation Handbook , 2009 .

[25]  M. Rupp,et al.  Improving Cleaning of the Environment Surrounding Patients in 36 Acute Care Hospitals , 2008, Infection Control & Hospital Epidemiology.

[26]  K. Linden,et al.  Pulsed UV lamp performance and comparison with UV mercury lamps , 2007 .

[27]  Shixia Wang,et al.  Assays for the assessment of neutralizing antibody activities against Severe Acute Respiratory Syndrome (SARS) associated coronavirus (SCV) , 2005, Journal of Immunological Methods.

[28]  S. Dowell,et al.  Severe Acute Respiratory Syndrome Coronavirus on Hospital Surfaces , 2004, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[29]  B. Lim,et al.  Inhibition of SARS Coronavirus Infection In Vitro with Clinically Approved Antiviral Drugs , 2004, Emerging infectious diseases.