A simplified optical lattice clock

Existing optical lattice clocks demonstrate a high level of performance but they remain complex experimental devices. In order to address a wider range of applications including those requiring transportable devices, it will be necessary to simplify the laser systems and reduce the amount of support hardware. Here we demonstrate two significant steps towards this goal: demonstration of clock signals from a Sr lattice clock based solely on semiconductor laser technology, and a method for finding the clock transition (based on a coincidence in atomic wavelengths) that removes the need for extensive frequency metrology hardware. Moreover, the unexpected high contrast in the signal revealed evidence of density dependent collisions in 88Sr atoms.

[1]  Jun Ye,et al.  Precision spectroscopy and density-dependent frequency shifts in ultracold Sr. , 2005, Physical review letters.

[2]  J Ye,et al.  Compact, thermal-noise-limited optical cavity for diode laser stabilization at 1x10(-15). , 2007, Optics letters.

[3]  Jun Ye,et al.  Sr Lattice Clock at 1 × 10–16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock , 2008, Science.

[4]  G. Tino,et al.  Strontium Optical Lattice Clock with All Semiconductor Sources , 2007, 2007 IEEE International Frequency Control Symposium Joint with the 21st European Frequency and Time Forum.

[5]  Tetsuya Ido,et al.  87Sr lattice clock with inaccuracy below 10 -15. , 2007, Physical review letters.

[6]  G Ferrari,et al.  Precision frequency measurement of visible intercombination lines of strontium. , 2003, Physical review letters.

[7]  Guglielmo M. Tino,et al.  Prospect for a compact strontium optical lattice clock , 2007, SPIE Optical Engineering + Applications.

[8]  F. Riehle,et al.  Ultracold 88Sr atoms for an optical lattice clock , 2007, 2007 IEEE International Frequency Control Symposium Joint with the 21st European Frequency and Time Forum.

[9]  Rodolphe Le Targat,et al.  Accuracy evaluation of an optical lattice clock with bosonic atoms. , 2007, Optics letters.

[10]  P. Rosenbusch,et al.  An optical lattice clock with spin-polarized 87Sr atoms , 2007, 0710.0086.

[11]  Massimo Inguscio,et al.  Spectroscopy of the 689 nm intercombination line of strontium using an extended-cavity InGaP/InGaAIP diode laser , 1992 .

[12]  L. Hollberg,et al.  Frequency evaluation of the doubly forbidden $^1S_0\to ^3P_0$ transition in bosonic $^{174}$Yb , 2008, 0803.4503.

[13]  R. Deslattes,et al.  Laser wavelength comparison by high resolution interferometry. , 1976, Applied optics.

[14]  T Zelevinsky,et al.  New limits on coupling of fundamental constants to gravity using 87Sr optical lattice clocks. , 2008, Physical review letters.

[15]  M. Takamoto,et al.  An optical lattice clock , 2005, Nature.

[16]  Optical transfer cavity stabilization using current-modulated injection-locked diode lasers , 2006, physics/0606065.

[17]  Time too good to be true , 2006 .

[18]  D. Wineland,et al.  Frequency Ratio of Al+ and Hg+ Single-Ion Optical Clocks; Metrology at the 17th Decimal Place , 2008, Science.

[19]  C W Oates,et al.  Magnetic field-induced spectroscopy of forbidden optical transitions with application to lattice-based optical atomic clocks. , 2006, Physical review letters.