Ocular aberrations up to the infrared range: from 632.8 to 1070 nm.

Ocular aberrations were measured by using a Hartmann-Shack wavefront sensor in the visible and infrared portions of the spectrum. In the latter, wavelengths 1030, 1050 and 1070 nm were used for the first time for the study of the optical quality of the eye. In this spectral range the retinal photoreceptors barely respond, so the radiation is virtually invisible for the subject. The results were confronted with those obtained by the same system at 780 and 632.8 nm. Monochromatic aberrations were found to be similar from the visible to the infrared. Longitudinal chromatic aberration was experimentally obtained, being approximately 1 D from 632.8 to 1070 nm. The feasibility of using the infrared for studying the eye was demonstrated. The employment of the infrared has an enormous potential for the better understanding of the impact and influence of the aberrations in vision with adaptive optics. It allows for measuring and controlling aberrations whilst the subject might eventually perform visual tests, with no interference from the beacon light.

[1]  R. Navarro,et al.  Odd aberrations and double-pass measurements of retinal image quality. , 1995, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  D H Sliney,et al.  Visual sensitivity of the eye to infrared laser radiation. , 1976, Journal of the Optical Society of America.

[3]  David R Williams,et al.  Accommodation with higher-order monochromatic aberrations corrected with adaptive optics. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[4]  I Iglesias,et al.  Closed-loop adaptive optics in the human eye. , 2001, Optics letters.

[5]  R. Dhillon,et al.  For the safe use of lasers , 1989 .

[6]  P Artal,et al.  Analysis of the performance of the Hartmann-Shack sensor in the human eye. , 2000, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  H. J. Leebeek,et al.  Foveal sensitivity of the human eye in the near infrared. , 1963, Journal of the Optical Society of America.

[8]  F. Delori,et al.  Spectral reflectance of the human ocular fundus. , 1989, Applied optics.

[9]  Junzhong Liang,et al.  Aberrations and retinal image quality of the normal human eye. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[10]  J. Fujimoto,et al.  Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second. , 2007, Optics letters.

[11]  Christopher Dainty,et al.  Adaptive optics system for investigation of the effect of the aberration dynamics of the human eye on steady-state accommodation control. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Pablo Artal,et al.  Adaptive optics visual simulator. , 2002, Journal of refractive surgery.

[13]  G. Wyszecki,et al.  Axial chromatic aberration of the human eye. , 1957, Journal of the Optical Society of America.

[14]  M S SMIRNOV,et al.  [Measurement of the wave aberration of the human eye]. , 1961, Biofizika.

[15]  Pablo Artal,et al.  Study on the effects of monochromatic aberrations in the accommodation response by using adaptive optics. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[16]  A. Bradley,et al.  The longitudinal chromatic aberration of the human eye, and its correction , 1986, Vision Research.

[17]  P. Artal,et al.  Ocular aberrations as a function of wavelength in the near infrared measured with a femtosecond laser. , 2005, Optics express.

[18]  I Iglesias,et al.  Estimates of the ocular wave aberration from pairs of double-pass retinal images. , 1998, Journal of the Optical Society of America. A, Optics, image science, and vision.

[19]  W N Charman,et al.  Objective technique for the determination of monochromatic aberrations of the human eye. , 1984, Journal of the Optical Society of America. A, Optics and image science.

[20]  David R Williams,et al.  Neural compensation for the eye's optical aberrations. , 2004, Journal of vision.

[21]  N A Brennan,et al.  Anatomically accurate, finite model eye for optical modeling. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[22]  B. Howland,et al.  A subjective method for the measurement of monochromatic aberrations of the eye. , 1977, Journal of the Optical Society of America.

[23]  D. Brainard,et al.  Double-pass and interferometric measures of the optical quality of the eye. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[24]  S. Yun,et al.  In vivo optical frequency domain imaging of human retina and choroid. , 2006, Optics express.

[25]  A. Bradley,et al.  The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans. , 1992, Applied optics.

[26]  G WALD,et al.  The sensitivity of the human eye to infra-red radiation. , 1947, Journal of the Optical Society of America.

[27]  C. Gray,et al.  Natural movies evoke precise responses in cat visual cortex that are not predicted from non-uniform Poisson processes , 2004 .

[28]  W. Drexler,et al.  In vivo retinal optical coherence tomography at 1040 nm - enhanced penetration into the choroid. , 2005, Optics express.

[29]  Junzhong Liang,et al.  Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[30]  Pablo Artal,et al.  Adaptive optics simulation of intraocular lenses with modified spherical aberration. , 2004, Investigative ophthalmology & visual science.

[31]  Pablo Artal,et al.  A wavelength tunable wavefront sensor for the human eye. , 2008, Optics express.

[32]  George Smith,et al.  Chromatic dispersions of the ocular media of human eyes. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[33]  J Jahns,et al.  Optical interconnects using top-surface-emitting microlasers and planar optics. , 1992, Applied optics.

[34]  D. Norren,et al.  The Pathways of Light Measured in Fundus Reflectometry , 1996, Vision Research.

[35]  W. Charman,et al.  Objective measurements of the longitudinal chromatic aberration of the human eye , 1976, Vision Research.

[36]  Smirnov Ms Measurement of the wave aberration of the human eye , 1961 .

[37]  Y. Yasuno,et al.  Full-range, high-speed, high-resolution 1 microm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. , 2008, Optics express.