Intraoperative evaluation of revascularization effect on ischemic muscle hemodynamics using near-infrared diffuse optical spectroscopies.

Arterial revascularization in patients with peripheral arterial disease (PAD) reestablishes large arterial blood supply to the ischemic muscles in lower extremities via bypass grafts or percutaneous transluminal angioplasty (PTA). Currently no gold standard is available for assessment of revascularization effects in lower extremity muscles. This study tests a novel near-infrared diffuse correlation spectroscopy flow-oximeter for monitoring of blood flow and oxygenation changes in medial gastrocnemius (calf) muscles during arterial revascularization. Twelve limbs with PAD undergoing revascularization were measured using a sterilized fiber-optic probe taped on top of the calf muscle. The optical measurement demonstrated sensitivity to dynamic physiological events, such as arterial clamping/releasing during bypass graft and balloon inflation/deflation during PTA. Significant elevations in calf muscle blood flow were observed after revascularization in patients with bypass graft (+48.1 ± 17.5%) and patients with PTA (+43.2 ± 11.0%), whereas acute post-revascularization effects in muscle oxygenation were not evident. The decoupling of flow and oxygenation after revascularization emphasizes the need for simultaneous measurement of both parameters. The acute elevations/improvements in calf muscle blood flow were associated with significant improvements in symptoms and functions. In total, the investigation corroborates potential of the optical methods for objectively assessing the success of arterial revascularization.

[1]  Martin Wolf,et al.  Localized irregularities in hemoglobin flow and oxygenation in calf muscle in patients with peripheral vascular disease detected with near-infrared spectrophotometry. , 2003, Journal of vascular surgery.

[2]  W. Hiatt,et al.  Medical treatment of peripheral arterial disease and claudication. , 2001, The New England journal of medicine.

[3]  Guoqiang Yu,et al.  Portable optical tissue flow oximeter based on diffuse correlation spectroscopy. , 2009, Optics letters.

[4]  D. Taggart,et al.  Intraoperative imaging techniques to assess coronary artery bypass graft patency. , 2007, The Annals of thoracic surgery.

[5]  S. Muthayya,et al.  In vivo arginine production and nitric oxide synthesis in pregnant Indian women with normal and low body mass indices , 2009, European Journal of Clinical Nutrition.

[6]  B. Chance,et al.  Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies. , 2005, Journal of biomedical optics.

[7]  J. Feinglass,et al.  Functional status and walking ability after lower extremity bypass grafting or angioplasty for intermittent claudication: results from a prospective outcomes study. , 2000, Journal of vascular surgery.

[8]  Hanli Liu,et al.  Investigation of rat breast tumour oxygen consumption by near-infrared spectroscopy , 2005 .

[9]  J. Halperin,et al.  Limitation of the resting ankle-brachial index in symptomatic patients with peripheral arterial disease , 2006, Vascular medicine.

[10]  D. Delpy,et al.  Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation. , 1988, Biochimica et biophysica acta.

[11]  A. Kienle,et al.  In vivo determination of the optical properties of muscle with time-resolved reflectance using a layered model. , 1999, Physics in medicine and biology.

[12]  W. Colier,et al.  Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle. , 2001, Clinical science.

[13]  Andrea Surova,et al.  Noninvasive optical measures of CBV, StO2, CBF index, and rCMRO2 in human premature neonates' brains in the first six weeks of life , 2011 .

[14]  J. Detre,et al.  Diffuse optical measurement of blood flow, blood oxygenation, and metabolism in a human brain during sensorimotor cortex activation. , 2004, Optics letters.

[15]  D. Boas,et al.  Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation , 1997 .

[16]  Susan M. Schultz,et al.  Cerebral hemodynamics in preterm infants during positional intervention measured with diffuse correlation spectroscopy and transcranial Doppler ultrasound. , 2009, Optics express.

[17]  U. Tebbe,et al.  Impact of early perfusion status of the infarct-related artery on short-term mortality after thrombolysis for acute myocardial infarction: retrospective analysis of four German multicenter studies. , 1993, Journal of the American College of Cardiology.

[18]  C. Willy,et al.  Long‐term invasive measurement of subcutaneous oxygen partial pressure above the sacrum on lying healthy volunteers , 2006, Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society.

[19]  Arjun G. Yodh,et al.  Diffuse optical measurement of blood flow in breast tumors , 2005 .

[20]  M S Patterson,et al.  Influence of layered tissue architecture on estimates of tissue optical properties obtained from spatially resolved diffuse reflectometry. , 1998, Applied optics.

[21]  M. Hopman,et al.  Near infrared spectroscopy for noninvasive assessment of claudication. , 1997, The Journal of surgical research.

[22]  J. Kleijnen,et al.  A systematic review of duplex ultrasound, magnetic resonance angiography and computed tomography angiography for the diagnosis and assessment of symptomatic, lower limb peripheral arterial disease. , 2007, Health technology assessment.

[23]  J. Maris,et al.  31P nuclear magnetic resonance spectroscopy: noninvasive biochemical analysis of the ischemic extremity. , 1986, Journal of vascular surgery.

[24]  D. Delpy,et al.  Near‐infrared spectroscopy in peripheral vascular disease , 1991, The British journal of surgery.

[25]  G. Maret Diffusing-Wave Spectroscopy , 1997 .

[26]  J. Detre,et al.  Noninvasive Measurement of Cerebral Blood Flow and Blood Oxygenation Using Near-Infrared and Diffuse Correlation Spectroscopies in Critically Brain-Injured Adults , 2010, Neurocritical care.

[27]  Yu Shang,et al.  Diffuse Optical Spectroscopies for Evaluation of Muscle Hemodynamic Enchantments by Electrical Stimulation , 2010 .

[28]  John P Allegrante,et al.  Body mass indices in patients with disabling hip osteoarthritis , 2001, Arthritis research.

[29]  B. Tromberg,et al.  Diffuse optical monitoring of blood flow and oxygenation in human breast cancer during early stages of neoadjuvant chemotherapy. , 2007, Journal of biomedical optics.

[30]  Beniamino B. Barbieri,et al.  Results of a 95-subject human clinical trial for the diagnosis of peripheral vascular disease using a near-infrared frequency domain hemoglobin spectrometer , 1999, Biomedical optics.

[31]  D. Boas,et al.  Noninvasive optical measures of CBV, StO2, CBF index, and rCMRO2 in human premature neonates' brains in the first six weeks of life , 2010, Human brain mapping.

[32]  David A. Boas,et al.  Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters , 2003, NeuroImage.

[33]  A. Yodh,et al.  In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies. , 2001, Physics in medicine and biology.

[34]  Lelia Adelina Paunescu,et al.  Tissue Blood Flow and Oxygen Consumption Measured With Near -Infrared Frequency -Domain Spectroscopy , 2001 .

[35]  Turgut Durduran,et al.  Noninvasive measurements of tissue hemodynamics with hybrid diffuse optical methods , 2004 .

[36]  Non-Invasive Measurement of Skeletal Muscle Contraction with Time-Resolved Diffusing-Wave Spectroscopy , 2010 .

[37]  R. Sawaqed,et al.  Prospective Comparison of Intraoperative Angiography with Duplex Scanning in Evaluating Lower-Extremity Bypass Grafts in a Community Hospital , 2001, The American surgeon.

[38]  F. Werf DISCREPANCIES BETWEEN THE EFFECTS OF CORONARY REPERFUSION ON SURVIVAL AND LEFT VENTRICULAR FUNCTION , 1989, The Lancet.

[39]  D. Harrington,et al.  Patency Results of Percutaneous and Surgical Revascularization for Femoropopliteal Arterial Disease , 1994, Medical decision making : an international journal of the Society for Medical Decision Making.

[40]  Youxin Mao,et al.  Feasibility of interstitial Doppler optical coherence tomography for in vivo detection of microvascular changes during photodynamic therapy , 2006, Lasers in surgery and medicine.

[41]  Shoko Nioka,et al.  Noninvasive diffuse optical measurement of blood flow and blood oxygenation for monitoring radiation therapy in patients with head and neck tumors: a pilot study. , 2006, Journal of biomedical optics.

[42]  Hiroyuki Ishibashi,et al.  Clinical reliability and utility of skin perfusion pressure measurement in ischemic limbs--comparison with other noninvasive diagnostic methods. , 2008, Journal of vascular surgery.

[43]  A. Yodh,et al.  Effects of muscle fiber motion on diffuse correlation spectroscopy blood flow measurements during exercise , 2010, Biomedical optics express.

[44]  D. Weitz,et al.  Diffusing wave spectroscopy. , 1988, Physical review letters.

[45]  A. Halim,et al.  Noninvasive assessment of cutaneous vascular function in vivo using capillaroscopy, plethysmography and laser-Doppler instruments: its strengths and weaknesses. , 2006, Clinical hemorheology and microcirculation.

[46]  J. Feinglass,et al.  Measures of success and health-related quality of life in lower-extremity vascular surgery. , 2000, Annual review of medicine.

[47]  E. Gratton,et al.  Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy. , 1999, Physics in medicine and biology.

[48]  J. Detre,et al.  Transcranial optical monitoring of cerebrovascular hemodynamics in acute stroke patients. , 2009, Optics express.

[49]  G. Maret,et al.  Multiple light scattering from disordered media. The effect of brownian motion of scatterers , 1987 .

[50]  H. Konno,et al.  Preservation of pelvic circulation with hypogastric artery bypass in endovascular repair of abdominal aortic aneurysm with bilateral iliac artery aneurysms. , 2006, Journal of vascular surgery.

[51]  M. Kern,et al.  Determination of angiographic (TIMI grade) blood flow by intracoronary Doppler flow velocity during acute myocardial infarction. , 1996, Circulation.

[52]  Arjun G. Yodh,et al.  Noninvasive Monitoring of Murine Tumor Blood Flow During and After Photodynamic Therapy Provides Early Assessment of Therapeutic Efficacy , 2005, Clinical Cancer Research.

[53]  Campbell,et al.  Scattering and Imaging with Diffusing Temporal Field Correlations. , 1995, Physical review letters.

[54]  Wolfhard Semmler,et al.  Volumetric high-frequency Doppler ultrasound enables the assessment of early antiangiogenic therapy effects on tumor xenografts in nude mice , 2008, European Radiology.

[55]  A. Yodh,et al.  Diffuse Optical Tomography of Cerebral Blood Flow, Oxygenation, and Metabolism in Rat during Focal Ischemia , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[56]  K. McCully,et al.  Exercise-induced changes in oxygen saturation in the calf muscles of elderly subjects with peripheral vascular disease. , 1994, Journal of gerontology.

[57]  R FONTAINE,et al.  [Surgical treatment of peripheral circulation disorders]. , 1954, Helvetica chirurgica acta.

[58]  A. Nini,et al.  Near-infrared spectroscopy for evaluation of peripheral vascular disease. A systematic review of literature. , 2008, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[59]  G. Dietsche,et al.  Fiber-based multispeckle detection for time-resolved diffusing-wave spectroscopy: characterization and application to blood flow detection in deep tissue. , 2007, Applied optics.

[60]  T. Floyd,et al.  Validation of diffuse correlation spectroscopy for muscle blood flow with concurrent arterial spin labeled perfusion MRI. , 2007, Optics express.

[61]  R. Ichord,et al.  Diffuse optical monitoring of hemodynamic changes in piglet brain with closed head injury. , 2009, Journal of biomedical optics.

[62]  H. Konno,et al.  Indocyanine green fluorescence angiography for intraoperative assessment of blood flow: a feasibility study. , 2008, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[63]  P. M. Lugarà,et al.  Application of near-infrared tissue oxymetry to the diagnosis of peripheral vascular disease. , 1999, Clinical hemorheology and microcirculation.

[64]  J. Wong,et al.  Intermittent claudication: cost-effectiveness of revascularization versus exercise therapy. , 2002, Radiology.

[65]  Ron A. Wevers,et al.  Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle. , 2001 .

[66]  D. Delpy,et al.  Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. , 1995, Physics in medicine and biology.

[67]  T. Elbert,et al.  Transient functional blood flow change in the human brain measured noninvasively by diffusing-wave spectroscopy. , 2008, Optics letters.

[68]  E. Cummins,et al.  The clinical effectiveness and cost-effectiveness of inhaled insulin in diabetes mellitus: a systematic review and economic evaluation. , 2007, Health technology assessment.

[69]  Louis Gagnon,et al.  Investigation of diffuse correlation spectroscopy in multi-layered media including the human head. , 2008, Optics express.

[70]  Philip Greenland,et al.  Leg symptoms, the ankle-brachial index, and walking ability in patients with peripheral arterial disease , 1999, Journal of General Internal Medicine.