Randomized clinical trial of propofol versus methohexital for procedural sedation during fracture and dislocation reduction in the emergency department.

UNLABELLED Although methohexital has been well studied for use in emergency department (ED) procedural sedation (PS), propofol has been evaluated less extensively for ED use. OBJECTIVE The authors hypothesized that there is no difference in the depth of sedation and the rate of respiratory depression (RD) between propofol and methohexital in PS during the reduction of fractures and dislocations in the ED. METHODS This was a randomized prospective study of nonintoxicated adult patients undergoing PS for fracture or dislocation reduction in the ED between July 2001 and March 2002. Patients were randomized to receive either propofol or methohexital, 1 mg/kg intravenously, followed by repeat boluses of 0.5 mg/kg every 2 minutes until adequate sedation was achieved. Doses, vital signs, end-tidal CO(2) (ETCO(2)) by nasal cannulae, pulse oximetry, and bispectral electroencephalogram analysis (BIS) scores were recorded. RD was defined as an ETCO(2) greater than 50 torr, an oxygen saturation less than 90% at any time, or an absent ETCO(2) waveform. After returning to baseline mental status, patients completed three 100-mm visual analog scales (VASs) regarding pain associated with the procedure, recall of the procedure, and satisfaction. RD rates and VAS outcomes were compared with chi-square tests. RESULTS There were 109 patients enrolled; six were excluded for study protocol violations. Of the remaining 103 patients, 52 received methohexital (reduction successful in 94%) and 51 received propofol (98% successful). No cardiac rhythm abnormalities or significant decline in systolic blood pressure (>20%) was detected. Six patients required bag-valve-mask-assisted ventilations during the procedure, all for less than 1 minute; four of these patients received methohexital, and two received propofol. By the authors' definition, RD was seen in 25 of 52 (48%) patients receiving methohexital and 25 of 51 (49%) patients receiving propofol (p = 0.88). The mean minimum recorded BIS score was 66.2 (95% confidence interval [CI] = 62 to 70) for methohexital and 66 (95% CI = 60 to 71) for propofol. VAS results showed similar rates of reported pain, recall, and satisfaction for the two agents. CONCLUSIONS The authors were unable to detect a significant difference in the level of subclinical RD or the level of sedation by BIS between the two agents. The use of either agent seems to be safe in the ED.

[1]  M. Biros,et al.  Bispectral electroencephalographic analysis of patients undergoing procedural sedation in the emergency department. , 2003, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[2]  B. Krauss,et al.  A study of the Bispectral Index Monitor during procedural sedation and analgesia in the emergency department. , 2003, Annals of emergency medicine.

[3]  J. Miner,et al.  End-tidal carbon dioxide monitoring during procedural sedation. , 2002, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[4]  P. Blackburn,et al.  Pharmacology of emergency department pain management and conscious sedation. , 2000, Emergency medicine clinics of North America.

[5]  M. Zimpfer,et al.  Propofol without muscle relaxants for conventional or fiberoptic nasotracheal intubation: a dose-finding study. , 2000, Anesthesia and analgesia.

[6]  P. Glass,et al.  Changes in the Auditory Evoked Potentials and the Bispectral Index following Propofol or Propofol and Alfentanil , 2000, Anesthesiology.

[7]  R. Strait,et al.  A clinical trial of propofol vs midazolam for procedural sedation in a pediatric emergency department. , 1999, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[8]  J. Tobias,et al.  End-tidal carbon dioxide monitoring during sedation with a combination of midazolam and ketamine for children undergoing painful, invasive procedures. , 1999, Pediatric emergency care.

[9]  M. Struys,et al.  Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients , 1998, Intensive Care Medicine.

[10]  M. P. Poirier,et al.  Utility of monitoring capnography, pulse oximetry, and vital signs in the detection of airway mishaps: a hyperoxemic animal model. , 1998, The American journal of emergency medicine.

[11]  L. Kearse,et al.  Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and Hypnosis , 1998, Anesthesiology.

[12]  P. White,et al.  Use of Alfentanil and Propofol for Outpatient Monitored Anesthesia Care: Determining the Optimal Dosing Regimen , 1997, Anesthesia and analgesia.

[13]  S. Berns,et al.  The value of end-tidal CO2 monitoring when comparing three methods of conscious sedation for children undergoing painful procedures in the emergency department , 1997, Pediatric emergency care.

[14]  Peter S. Sebel,et al.  Bispectral Analysis Measures Sedation and Memory Effects of Propofol, Midazolam, Isoflurane, and Alfentanil in Healthy Volunteers , 1997, Anesthesiology.

[15]  P. White,et al.  Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation , 1997, Anesthesia and analgesia.

[16]  M. Levitt,et al.  A prospective evaluation of the safety and efficacy of methohexital in the emergency department. , 1996, The American journal of emergency medicine.

[17]  R. Friesen,et al.  End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: Accuracy and sources of error , 1996, Journal of Clinical Monitoring.

[18]  K. Leslie,et al.  Propofol Blood Concentration and the Bispectral Index Predict Suppression of Learning During Propofol/Epidural Anesthesia in Volunteers , 1995, Anesthesia and analgesia.

[19]  P. White,et al.  Methods for monitoring the level of sedation. , 1995, Critical care clinics.

[20]  Juras Ep Methohexital for orthopaedic procedures in the emergency department. , 1994 .

[21]  S. Eisig,et al.  Comparison of propofol and methohexital for deep sedation. , 1994, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[22]  J. Bono,et al.  Methohexital for orthopaedic procedures in the emergency department. , 1993, Orthopedic Reviews.

[23]  K. A. East,et al.  Frequent hypoxemia and apnea after sedation with midazolam and fentanyl. , 1990, Anesthesiology.

[24]  N. Sandler The use of bispectral analysis to monitor outpatient sedation. , 2000, Anesthesia progress.

[25]  Paul F. White,et al.  Electroencephalogram bispectral analysis predicts the depth of midazolam-induced sedation. , 1996 .

[26]  S. J. Prstojevich,et al.  Utility of capnography in predicting venous carbon dioxide partial pressure in sedated patients during outpatient oral surgery. , 1992, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.