Research and Developments in Medical Image Reconstruction Methods and its Applications

Image reconstruction from projection is the field that lays the foundation for Medical Imaging or Medical Image Processing. The rapid and proceeding progress in medical image reconstruction, and the related developments in analysis methods and computer-aided diagnosis, has promoted medical imaging into one of the most important sub-fields in scientific imaging. Computer technology has enabled tomographic and three-dimensional reconstruction of images, illustrating both anatomical features and physiological functioning, free from overlying structures. In this chapter, the authors share their opinions on the research and development in the field of Medical Image Reconstruction Techniques, Computed Tomography (CT), challenges and the impact of future technology developments in CT, Computed Tomography Metrology in industrial research & development, technology, and clinical performance of different CT-scanner generations used for cardiac imaging, such as Electron Beam CT (EBCT), single-slice CT, and MultiDetector row CT (MDCT) with 4, 16, and 64 simultaneously acquired slices. The authors identify the limitations of current CT-scanners, indicate potential of improvement and discuss alternative system concepts such as CT with area detectors and Dual Source CT (DSCT), recent technology with a focus on generation and detection of X-rays, as well as image reconstruction are discussed. Furthermore, the chapter includes aspects of applications, dose exposure in computed tomography, and a brief overview on special CT developments. Since this chapter gives a review of the major accomplishments and future directions in this field, with emphasis on developments over the past 50 years, the interested reader is referred to recent literature on computed tomography including a detailed discussion of CT technology in the references section. Research and Developments in Medical Image Reconstruction Methods and Its Applications

[1]  R Gordon,et al.  Detection of early breast cancer: an overview and future prospects. , 1989, Critical reviews in biomedical engineering.

[2]  L. Shepp,et al.  A Statistical Model for Positron Emission Tomography , 1985 .

[3]  P. Geethanjali Design and Development of EMG Conditioning System and Hand Gesture Recognition Based on Principal Component Analysis Feature Reduction Technique , 2014 .

[4]  R. Walle,et al.  Iterative reconstruction algorithms in nuclear medicine. , 2001, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[5]  Charles L. Epstein Introduction to the Mathematics of Medical Imaging, Second Edition , 2007 .

[6]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[7]  R. Srinivasan Methods to Improve the Spatial Resolution of EEG , 1999 .

[8]  A. Dores,et al.  Computer-Based Neuropsychological Rehabilitation: Virtual Reality and Serious Games , 2016 .

[9]  Daniel Kolditz,et al.  Iterative reconstruction methods in X-ray CT. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  D. Hilbert Grundzuge Einer Allgemeinen Theorie Der Linearen Integralgleichungen , 2009 .

[11]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Eric C. Frey,et al.  Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction , 1991 .

[13]  Ulla Ruotsalainen,et al.  Using local median as the location of the prior distribution in iterative emission tomography image reconstruction , 1997 .

[14]  K. Wickersheim,et al.  X-ray exposure reduction using rare-earth oxysulfide intensifying screens. , 1972, Radiology.

[15]  S. Abramson,et al.  Adrenal neoplasms in children. , 1997, Radiologic clinics of North America.

[16]  Yongyi Yang,et al.  5D Image Reconstruction for Tomographic Image Sequences , 2006, 2006 Fortieth Asilomar Conference on Signals, Systems and Computers.

[17]  P. Green Bayesian reconstructions from emission tomography data using a modified EM algorithm. , 1990, IEEE transactions on medical imaging.

[18]  Paulo Estevão Cruvinel,et al.  X- and gamma -rays computerized minitomograph scanner for soil science , 1990 .

[19]  G. Dougherty,et al.  Computerized evaluation of mammographic image quality using phantom images. , 1998, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[20]  Maria Manuela Cruz-Cunha,et al.  Encyclopedia of E-Health and Telemedicine , 2016 .

[21]  Gabor T. Herman,et al.  Fundamentals of Computerized Tomography: Image Reconstruction from Projections , 2009, Advances in Pattern Recognition.

[22]  K A Girodias,et al.  Parallel simulated annealing for emission tomography. , 1991, Physics in medicine and biology.

[23]  A. Devaney A filtered backpropagation algorithm for diffraction tomography. , 1982, Ultrasonic imaging.

[24]  Zhengrong Liang,et al.  Bayesian reconstruction in emission computerized tomography , 1988 .

[25]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[26]  R. Lewis,et al.  Recent advances in biomedical imaging systems , 2009, Proceedings of the 2009 12th International Symposium on Integrated Circuits.

[27]  Klaus Mueller,et al.  Fast and accurate projection algorithm for 3D cone-beam reconstruction with the Algebraic Reconstruction Technique (ART) , 1998, Medical Imaging.

[28]  Andrei V. Bronnikov,et al.  Phase-contrast CT: fundamental theorem and fast image reconstruction algorithms , 2006, SPIE Optics + Photonics.

[29]  Jean-Louis Coatrieux,et al.  Assessment of Left Ventricular Function in Cardiac MSCT Imaging by a 4D Hierarchical Surface-Volume Matching Process , 2006, Int. J. Biomed. Imaging.

[30]  T. Hebert,et al.  A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors. , 1989, IEEE transactions on medical imaging.

[31]  M. Franceschini,et al.  Monitoring brain activity using near-infrared light , 2001 .

[32]  Michael Grasruck,et al.  Flat-panel volume CT: fundamental principles, technology, and applications. , 2008, Radiographics : a review publication of the Radiological Society of North America, Inc.

[33]  Joseph Webster Stayman,et al.  Spatial resolution in penalized -likelihood image reconstruction. , 2003 .

[34]  M. Goitein Three-dimensional density reconstruction from a series of two-dimensional projections , 1972 .

[35]  Yang Lu,et al.  Overview of multisource CT systems and methods , 2010, Optical Engineering + Applications.

[36]  A. V. Nelson,et al.  Topographical mapping of brain electrical activity , 1991, Proceeding Visualization '91.

[37]  P. Gilbert Iterative methods for the three-dimensional reconstruction of an object from projections. , 1972, Journal of theoretical biology.

[38]  M. Teplan FUNDAMENTALS OF EEG MEASUREMENT , 2002 .

[39]  R. F. Wagner,et al.  Prospects for x-ray exposure reduction using rare earth intensifying screens. , 1976, Radiology.

[40]  LianLin Li,et al.  Tomographic Reconstruction Using the Distorted Rytov Iterative Method With Phaseless Data , 2008, IEEE Geoscience and Remote Sensing Letters.

[41]  R. Gordon A tutorial on art (algebraic reconstruction techniques) , 1974 .

[42]  A. Gevins The future of electroencephalography in assessing neurocognitive functioning. , 1998, Electroencephalography and clinical neurophysiology.

[43]  Bruno De Man,et al.  An outlook on x-ray CT research and development. , 2008, Medical physics.

[44]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[45]  Mehrdad Soumekh,et al.  Algorithms and experimental results in acoutistic tomography using Rytov's approximation , 1983, ICASSP.

[46]  Charles L. Byrne,et al.  Signal Processing: A Mathematical Approach , 1993 .

[47]  Mehrdad Soumekh,et al.  Image reconstruction from frequency domain data on arbitrary contours , 1984, ICASSP.

[48]  Paul Suetens Fundamentals of Medical Imaging , 2002 .

[49]  S. Alenius,et al.  Bayesian image reconstruction for emission tomography based on median root prior , 1997, European Journal of Nuclear Medicine.

[50]  E. Hecht,et al.  Dual-source versus single-source cardiac CT angiography: comparison of diagnostic image quality. , 2009, AJR. American journal of roentgenology.

[51]  P. Kuchment,et al.  Mathematics of thermoacoustic tomography , 2007, European Journal of Applied Mathematics.

[52]  E. Hoffman,et al.  Attenuation coefficients of various body tissues, fluids, and lesions at photon energies of 18 to 136 keV. , 1975, Radiology.

[53]  A. Kak,et al.  A computational study of reconstruction algorithms for diffraction tomography: Interpolation versus filtered-backpropagation , 1983 .

[54]  Lihong V. Wang,et al.  Photoacoustic imaging in biomedicine , 2006 .