Low-cost modular robotic system for neurological rehabilitative training

This paper presents the concept, development and testing of RoboTrainer-Light, a low-cost yet effective and usable training robot designed for use in the home. Although designed for simplicity and economic mass production, it is believed to enable a large section of patients with partial paralysis to perform effective neurological training in their own home. The robot consists of a wire-pulling motor combined with a sensitive force sensor, controlled by an ultra-high-bandwidth hybrid controller, allowing any combination of tension-, velocity- and length-control of the wire. The controller architecture is distributed and modular, allowing up to 15 wire pulling motors to be combined in parallel kinematic configurations. Compared to other rehabilitative robots, RoboTrainer-Light represents one of the simplest and cheapest possible configurations, which is further emphasized by our deliberate choice of low-cost components and technologies. Preliminary tests indicate that RoboTrainer-Light can support a large group of post-stroke and post-accident victims in effective neurological training in their own home or in local clinics, at an estimated cost lower than 500USD per unit for a high production volume.

[1]  N. Pedrocchi,et al.  Proprioceptivity and upper-extremity dynamics in robot-assisted reaching movement , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[2]  J. Moreno,et al.  The H2 robotic exoskeleton for gait rehabilitation after stroke: early findings from a clinical study , 2015, Journal of NeuroEngineering and Rehabilitation.

[3]  M. Gabriel Khan,et al.  Stroke/Cerebrovascular Accident , 2006 .

[4]  Nam-Jong Paik,et al.  The effect of aquatic therapy on postural balance and muscle strength in stroke survivors — a randomized controlled pilot trial , 2008, Clinical rehabilitation.

[5]  V. Feigin,et al.  Worldwide stroke incidence and early case fatality reported in 56 population-based studies: a systematic review , 2009, The Lancet Neurology.

[6]  P. Langhorne,et al.  Stroke rehabilitation , 2011, The Lancet.

[7]  P. Gallina,et al.  Design, Implementation and Clinical Tests of a Wire-Based Robot for Neurorehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[9]  Peter M. Rothwell,et al.  Stroke: Practical Management , 2008 .

[10]  Dragoljub Surdilovic,et al.  STRING-MAN: a new wire robot for gait rehabilitation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[11]  Kyler M. Godwin,et al.  Cost Associated with Stroke: Outpatient Rehabilitative Services and Medication , 2011, Topics in stroke rehabilitation.

[12]  Ulrik Pagh Schultz,et al.  Unity-link: A software-gateware interface for rapid prototyping of experimental robot controllers on FPGAs , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[13]  C. Burgar,et al.  MIME robotic device for upper-limb neurorehabilitation in subacute stroke subjects: A follow-up study. , 2006, Journal of rehabilitation research and development.

[14]  Anders Stengaard Sørensen,et al.  TosNet: An easy-to-use, real-time communications protocol for modular, distributed robot controllers , 2009, 2009 Second International Conference on Robot Communication and Coordination.

[15]  Federica De Santis,et al.  EPIDEMIOLOGY OF STROKE , 2002, Clinical and experimental hypertension.

[16]  Hermano Igo Krebs,et al.  MIT-MANUS: a workstation for manual therapy and training. I , 1992, [1992] Proceedings IEEE International Workshop on Robot and Human Communication.

[17]  J. Fung,et al.  Effects of robot-assisted therapy on stroke rehabilitation in upper limbs: systematic review and meta-analysis of the literature. , 2012, Journal of rehabilitation research and development.

[18]  Ulrik Pagh Schultz,et al.  Towards Using a Generic Robot as Training Partner Off-the-shelf robots as a platform for flexible and affordable rehabilitation , 2014, 2014 9th ACM/IEEE International Conference on Human-Robot Interaction (HRI).

[19]  L. Mertz,et al.  The Next Generation of Exoskeletons: Lighter, Cheaper Devices Are in the Works , 2012, IEEE Pulse.