Nonlabeled quartz crystal microbalance biosensor for bacterial detection using carbohydrate and lectin recognitions.

High percentages of harmful microbes or their secreting toxins bind to specific carbohydrate sequences on human cells at the recognition and attachment sites. A number of studies also show that lectins react with specific structures of bacteria and fungi. In this report, we take advantage of the fact that a high percentage of microorganisms have both carbohydrate and lectin binding pockets at their surface. We demonstrate here for the first time that a carbohydrate nonlabeled mass sensor in combination with lectin-bacterial O-antigen recognition can be used for detection of high molecular weight bacterial targets with remarkably high sensitivity and enhanced specificity. A functional mannose self-assembled monolayer in combination with lectin concanavalin A (Con A) was used as molecular recognition elements for the detection of Escherichia coli W1485 using a quartz crytsal microbalance (QCM) as a transducer. The multivalent binding of Con A to the E. coli surface O-antigen favors the strong adhesion of E. coli to the mannose-modified QCM surface by forming bridges between these two. As a result, the contact area between cell and QCM surface that increases leads to rigid and strong attachment. Therefore, it enhances the binding between E. coli and the mannose. Our results show a significant improvement of the sensitivity and specificity of the carbohydrate QCM biosensor with a experimental detection limit of a few hundred bacterial cells. The linear range is from 7.5 x 10(2) to 7.5 x 10(7) cells/mL, which is four decades wider than the mannose-alone QCM sensor. The change of damping resistances for E. coli adhesion experiments was no more than 1.4%, suggesting that the bacterial attachment was rigid, rather than a viscoelastic behavior. Little nonspecific binding was observed for Staphylococcus aureus and other proteins (fetal bovine serum, Erythrina cristagalli lectin). Our approach not only overcomes the challenges of applying QCM technology for bacterial detection but also increases the binding of bacteria to their carbohydrate receptor through bacterial surface binding lectins that significantly enhanced specificity and sensitivity of QCM biosensors. Combining carbohydrate and lectin recognition events with an appropriate QCM transducer can yield sensor devices highly suitable for the fast, reversible, and straightforward on-line screening and detection of bacteria in food, water, and clinical and biodefense areas.

[1]  Avraham Rasooly,et al.  Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk. , 2002, International journal of food microbiology.

[2]  O'sullivan,et al.  Human cytomegalovirus detection by a quartz crystal microbalance immunosensor. , 2000, Enzyme and microbial technology.

[3]  Milan Mrksich,et al.  A surface chemistry approach to studying cell adhesion , 2000 .

[4]  P Ertl,et al.  Electrochemical biosensor array for the identification of microorganisms based on lectin-lipopolysaccharide recognition. , 2001, Analytical chemistry.

[5]  B. Hallet,et al.  Playing Dr Jekyll and Mr Hyde: combined mechanisms of phase variation in bacteria. , 2001, Current opinion in microbiology.

[6]  T. Conway,et al.  Molecular genetic characterization of the Escherichia coli gntT gene of GntI, the main system for gluconate metabolism , 1997, Journal of bacteriology.

[7]  S. Yao,et al.  Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance. , 2002, Biosensors & bioelectronics.

[8]  K. Marx,et al.  Quartz crystal microbalance: a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface. , 2003, Biomacromolecules.

[9]  Ku-Lung Hsu,et al.  Analyzing the dynamic bacterial glycome with a lectin microarray approach , 2006, Nature chemical biology.

[10]  S. Kyes,et al.  Antigenic variation at the infected red cell surface in malaria. , 2001, Annual review of microbiology.

[11]  R. Buchanan,et al.  Foodborne Disease Significance of Escherichia coli O157:H7 and Other Enterohemorrhagic E. coli , 1997 .

[12]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[13]  L. Tessier,et al.  A new method based on acoustic impedance measurements for quartz immunosensors , 1997 .

[14]  B. Chin,et al.  Rapid and sensitive biosensor for Salmonella. , 2000, Biosensors & bioelectronics.

[15]  A. Barbour,et al.  Antigenic variation in vector-borne pathogens. , 2000, Emerging infectious diseases.

[16]  Xiangqun Zeng,et al.  Single-chain fragment variable antibody piezoimmunosensors. , 2005, Analytical chemistry.

[17]  N. Sharon,et al.  Lectins as molecules and as tools. , 1986, Annual review of biochemistry.

[18]  N. Packer,et al.  Structure of the O antigen of Escherichia coli K-12 and the sequence of its rfb gene cluster , 1994, Journal of bacteriology.

[19]  F. Chew,et al.  Self-assembled monolayer-based piezoelectric crystal immunosensor for the quantification of total human immunoglobulin E. , 1999, Analytical biochemistry.

[20]  K. Marx,et al.  The Quartz Crystal Microbalance as a Continuous Monitoring Tool for the Study of Endothelial Cell Surface Attachment and Growth , 2000, Biotechnology progress.

[21]  Y. Fung,et al.  Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect Salmonella in aqueous solution. , 2001, Analytical chemistry.

[22]  B. Chin,et al.  Specific and selective biosensor for Salmonella and its detection in the environment. , 2003, Journal of microbiological methods.

[23]  G. Lubrano,et al.  A quartz crystal microbalance displacement assay for Listeria monocytogenes , 1996 .

[24]  Xiangqun Zeng,et al.  Carbohydrate-protein interactions by "clicked" carbohydrate self-assembled monolayers. , 2006, Analytical chemistry.

[25]  N. Sharon,et al.  Lectins: Carbohydrate-Specific Proteins That Mediate Cellular Recognition. , 1998, Chemical reviews.

[26]  Michael Grätzel,et al.  Detection of viruses and bacteria with piezoelectric immunosensors , 1993 .

[27]  Y. Okahata,et al.  Kinetic Studies of Molecular Recognition Based on Hydrogen Bonding at the Air−Water Interface by Using a Highly Sensitive Quartz-Crystal Microbalance , 1996 .

[28]  K. Otto,et al.  Effect of Ionic Strength on Initial Interactions ofEscherichia coli with Surfaces, Studied On-Line by a Novel Quartz Crystal Microbalance Technique , 1999, Journal of bacteriology.

[29]  K. Otto,et al.  Inactivation of ompX Causes Increased Interactions of Type 1 Fimbriated Escherichia coli with Abiotic Surfaces , 2004, Journal of bacteriology.

[30]  G G Guilbault,et al.  Piezoelectric crystal biosensors. , 1990, Biosensors & bioelectronics.

[31]  L. Bao,et al.  Determination of microorganisms with a quartz crystal microbalance sensor , 1996 .

[32]  T. Pistole Interaction of bacteria and fungi with lectins and lectin-like substances. , 1981, Annual review of microbiology.

[33]  George G. Guilbault,et al.  Development of a quartz crystal microbalance (QCM) immunosensor for the detection of Listeria monocytogenes , 2001 .

[34]  R. Natesh,et al.  Crystal structures of Erythrina cristagalli lectin with bound N-linked oligosaccharide and lactose. , 2004, Glycobiology.

[35]  Liqun Huang,et al.  Detection of two orchid viruses using quartz crystal microbalance-based DNA biosensors. , 2002, Phytopathology.

[36]  K. Pavey,et al.  Application of the quartz crystal microbalance to the monitoring of Staphylococcus epidermidis antigen-antibody agglutination. , 1999, Journal of pharmaceutical and biomedical analysis.

[37]  I. Beacham,et al.  The interaction of concanavalin A with mutant and wild-type strains of Escherichia coli K12. , 1975, Biochemical Society transactions.

[38]  F. Pariente,et al.  A quartz crystal microbalance assay for detection of antibodies against the recombinant African swine fever virus attachment protein p12 in swine serum , 1998 .

[39]  Isao Karube,et al.  Piezoelectric immuno sensor for the detection of candida albicans microbes , 1986 .

[40]  R M Carter,et al.  Quartz crystal microbalance detection of Vibrio cholerae O139 serotype. , 1995, Journal of immunological methods.

[41]  I. Willner,et al.  Piezoelectric immunosensors for urine specimens of Chlamydia trachomatis employing quartz crystal microbalance microgravimetric analyses. , 1997, Analytical chemistry.

[42]  G G Guilbault,et al.  Development of a piezoelectric immunosensor for the detection of enterobacteria. , 1992, Enzyme and microbial technology.

[43]  B. Eisenstein Phase variation of type 1 fimbriae in Escherichia coli is under transcriptional control. , 1981, Science.

[44]  Yanbin Li,et al.  A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7. , 2004, Biosensors & bioelectronics.

[45]  I. Park,et al.  Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods. , 2003, Biosensors & bioelectronics.

[46]  X. Mao,et al.  A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7. , 2006, Biosensors & bioelectronics.

[47]  T. Kirikae,et al.  The chemical structure of bacterial endotoxin in relation to bioactivity. , 1993, Immunobiology.