Worldwide survey on the use of navigation in spine surgery.

OBJECTIVE Computer-assisted surgery (CAS) can improve the accuracy of screw placement and decrease radiation exposure, yet this is not widely accepted among spine surgeons. The current viewpoint of spine surgeons on navigation in their everyday practice is an important issue that has not been studied. A survey-based study assessed opinions on CAS to describe the current global attitudes of surgeons on the use of navigation in spine surgery. METHODS A 12-item questionnaire focusing on the number and type of surgical cases, the type of equipment available, and general opinions toward CAS was distributed to 3348 AOSpine surgeons (a specialty group within the AO [Arbeitsgemeinschaft für Osteosynthesefragen] Foundation). Latent class analysis was used to investigate the existence of specific groups based on the respondent opinion profiles. RESULTS A response rate of 20% was recorded. Despite a widespread distribution of navigation systems in North America and Europe, only 11% of surgeons use it routinely. High-volume procedure surgeons, neurological surgeons, and surgeons with a busy minimal invasive surgery practice are more likely to use CAS. "Routine users" consider the accuracy, potential of facilitating complex surgery, and reduction in radiation exposure as the main advantages. The lack of equipment, inadequate training, and high costs are the main reasons that "nonusers" do not use CAS. CONCLUSIONS Spine surgeons acknowledge the value of CAS, yet current systems do not meet their expectations in terms of ease of use and integration into the surgical work flow. To increase its use, CAS has to become more cost efficient and scientific data are needed to clarify its potential benefits.

[1]  Werner Krybus,et al.  Computer-assisted surgery , 1990, IEEE Computer Graphics and Applications.

[2]  T. Schwartz,et al.  Endonasal endoscopic resection of the odontoid process in a nonachondroplastic dwarf with juvenile rheumatoid arthritis: feasibility of the approach and utility of the intraoperative Iso-C three-dimensional navigation. Case report. , 2008, Journal of neurosurgery. Spine.

[3]  P Merloz,et al.  Pedicle Screw Placement Using Image Guided Techniques , 1998, Clinical orthopaedics and related research.

[4]  M. Austin,et al.  Image-Guided Spine Surgery: A Cadaver Study Comparing Conventional Open Laminoforaminotomy and Two Image-Guided Techniques for Pedicle Screw Placement in Posterolateral Fusion and Nonfusion Models , 2002, Spine.

[5]  H. Sagi,et al.  Electromagnetic Field-Based Image-Guided Spine Surgery Part Two: Results of a Cadaveric Study Evaluating Thoracic Pedicle Screw Placement , 2003, Spine.

[6]  Phillip M Young,et al.  Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. , 2009, Journal of neurosurgery. Spine.

[7]  L Zamorano,et al.  Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation. , 1996, Stereotactic and functional neurosurgery.

[8]  F. Langlotz,et al.  Clinical evaluation of a system for precision enhancement in spine surgery. , 1995, Clinical biomechanics.

[9]  D L Myers,et al.  Complications of Lumbar Spinal Fusion with Transpedicular Instrumentation , 1992, Spine.

[10]  P. Cummings Methods for Estimating Adjusted Risk Ratios , 2009 .

[11]  L. Nolte,et al.  Improved Accuracy of Pedicle Screw Insertion With Computer-Assisted Surgery: A Prospective Clinical Trial of 30 Patients , 1997, Spine.

[12]  C Ozdoba,et al.  Planning and insertion of pedicle screws with computer assistance. , 1997, Journal of spinal disorders.

[13]  G H Barnett,et al.  Application of frameless stereotaxy to pedicle screw fixation of the spine. , 1995, Journal of neurosurgery.

[14]  R. Härtl,et al.  Iso-C/3-dimensional neuronavigation versus conventional fluoroscopy for minimally invasive pedicle screw placement in lumbar fusion. , 2010, Minimally invasive neurosurgery : MIN.

[15]  Richard Assaker,et al.  Transpedicular Screw Placement: Image-Guided Versus Lateral-View Fluoroscopy:In Vitro Simulation , 2001, Spine.

[16]  Maurice M. Smith,et al.  Image-guided spine surgery. , 1996, Neurosurgery clinics of North America.

[17]  S Vidyadhara,et al.  Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries , 2007, Spine.

[18]  F. Langlotz,et al.  Accuracy of Computer‐Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis , 1997, Spine.

[19]  J. Hagenaars,et al.  Applied Latent Class Analysis , 2003 .