Operating Reserve Assessment in Systems with Energy Storage and Electric Vehicles

This paper evaluates the use of energy storage systems integrated to wind generation to increase the operating reserve of an electrical power network, in order to improve the short-term operation and reduce the risk of load interruption. The spinning reserve levels, which are required to ensure the system reliability, are assessed through risk indices evaluated using Monte Carlo simulation and cross-entropy method. Electrical vehicles insertion in the power network is represented as uncertainties in the short-term load model. The proposed method is applied to the IEEE-RTS-Wind system.

[1]  Armando Martins Leite da Silva,et al.  Spinning Reserve Assessment Under Transmission Constraints Based on Cross-Entropy Method , 2016, IEEE Transactions on Power Systems.

[2]  Probability Subcommittee,et al.  IEEE Reliability Test System , 1979, IEEE Transactions on Power Apparatus and Systems.

[3]  Armando M. Leite da Silva,et al.  Spinning reserve assessment via quasi-sequential Monte Carlo simulation with renewable sources , 2016, 2016 International Conference on Probabilistic Methods Applied to Power Systems (PMAPS).

[4]  João Peças Lopes,et al.  Probabilistic evaluation of reserve requirements of generating systems with renewable power sources: The Portuguese and Spanish cases , 2009 .

[5]  R. Billinton,et al.  Long-Term Probabilistic Evaluation of Operating Reserve Requirements With Renewable Sources , 2010, IEEE Transactions on Power Systems.

[6]  G. F. Reed,et al.  Survey of battery energy storage systems and modeling techniques , 2012, 2012 IEEE Power and Energy Society General Meeting.

[7]  Manuel A. Matos,et al.  Electric vehicle models for evaluating the security of supply , 2014 .

[8]  Bowen Zhou,et al.  The Impact of Vehicle-to-Grid on Electric Power Systems: A Review , 2013 .

[9]  L. T. Anstine,et al.  Application of Probability Methods to the Determination of Spinning Reserve Requirements for the Pennsylvania-New Jersey-Maryland Interconnection , 1963 .

[10]  Roy Billinton,et al.  Probabilistic Assessment of Spinning Reserve via Cross-Entropy Method Considering Renewable Sources and Transmission Restrictions , 2018, IEEE Transactions on Power Systems.

[11]  Armando M. Leite da Silva,et al.  Generating capacity reliability assessment of the Itaipu hydroelectric plant via sequential Monte Carlo simulation , 2014, 2014 Power Systems Computation Conference.

[12]  Warlley S. Sales,et al.  Reliability assessment of time-dependent systems via quasi-sequential Monte Carlo simulation , 2010, 2010 IEEE 11th International Conference on Probabilistic Methods Applied to Power Systems.

[13]  Georgianne Huff,et al.  DOE Global Energy Storage Database. , 2015 .

[14]  David L. Waltz,et al.  Vehicle Electrification: Status and Issues , 2011, Proceedings of the IEEE.

[15]  Chen Hao,et al.  Application and modeling of battery energy storage in power systems , 2016 .

[16]  A.M.L. da Silva,et al.  Generating Capacity Reliability Evaluation Based on Monte Carlo Simulation and Cross-Entropy Methods , 2010, IEEE Transactions on Power Systems.