Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior
暂无分享,去创建一个
Kuang-Huei Lee | Hao-Ming Hsiao | Yi-Hsiang Chiu | Chien-Han Lin | H. Hsiao | Kuang-Huei Lee | Chien-Han Lin | Yi-Hsiang Chiu
[1] S. Suresh. Fatigue of materials , 1991 .
[2] D. Ku,et al. Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.
[3] Patrick W Serruys,et al. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial , 2008, The Lancet.
[4] C Dumoulin,et al. Mechanical behaviour modelling of balloon-expandable stents. , 2000, Journal of biomechanics.
[5] F Joffre,et al. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. , 1987, The New England journal of medicine.
[6] Caitríona Lally,et al. Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy. , 2010, Journal of biomechanics.
[7] David N. Ku,et al. correlation between plaque location and low oscillating shear stress Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive , 2007 .
[8] M. S. Bruzzi,et al. Finite element comparison of performance related characteristics of balloon expandable stents , 2007, Computer methods in biomechanics and biomedical engineering.
[9] Pedro A. Lemos,et al. Drug‐Eluting Stents: Cost Versus Clinical Benefit , 2003, Circulation.
[10] William W O'Neill,et al. Drug-eluting stents: costs versus clinical benefit. , 2003, Circulation.
[11] Hao-Ming Hsiao,et al. Why similar stent designs cause new clinical issues. , 2012, JACC. Cardiovascular interventions.
[12] S Chien,et al. Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. , 1966, Journal of applied physiology.
[13] J J Wentzel,et al. Relationship Between Neointimal Thickness and Shear Stress After Wallstent Implantation in Human Coronary Arteries , 2001, Circulation.
[14] Huajiang Ouyang,et al. Shape optimization of coronary artery stent based on a parametric model , 2009 .
[15] Hao-Ming Hsiao,et al. Respiration-induced kidney motion on cobalt-chromium stent fatigue resistance. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.
[16] Shawn C. Shadden,et al. A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models , 2011, Annals of Biomedical Engineering.
[17] Abdul I. Barakat,et al. Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents , 2005, Annals of Biomedical Engineering.
[18] Gerhard A Holzapfel,et al. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. , 2005, Journal of biomechanical engineering.
[19] John F LaDisa,et al. Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. , 2005, American journal of physiology. Heart and circulatory physiology.
[20] P. Teirstein,et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. , 1994, The New England journal of medicine.
[21] Hao-Ming Hsiao,et al. Life Assessment of a Balloon-Expandable Stent for Atherosclerotic Renal Artery Stenosis , 2011 .
[22] F. Auricchio,et al. Mechanical behavior of coronary stents investigated through the finite element method. , 2002, Journal of biomechanics.
[23] Gregg W Stone,et al. Outcomes with the polymer-based paclitaxel-eluting TAXUS stent in patients with diabetes mellitus: the TAXUS-IV trial. , 2005, Journal of the American College of Cardiology.
[24] Lorenza Petrini,et al. On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method. , 2008, Journal of biomechanics.
[25] F. Etave,et al. Mechanical properties of coronary stents determined by using finite element analysis. , 2001, Journal of biomechanics.
[26] Peter E. McHugh,et al. Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling , 2004 .
[27] Patrick W Serruys,et al. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods , 2009, The Lancet.
[28] Zhonghua Ni,et al. Effects of Stent Design Parameters on Radial Force of Stent , 2008, 2008 2nd International Conference on Bioinformatics and Biomedical Engineering.
[29] Robert Burgermeister,et al. Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis. , 2006, Biomaterials.
[30] D. Ku. BLOOD FLOW IN ARTERIES , 1997 .
[31] Patrick W Serruys,et al. New frontiers in cardiology: drug-eluting stents: Part I. , 2003, Circulation.