Digital Loop-Mediated Isothermal Amplification on a Commercial Membrane

In this work, we report digital loop-mediated isothermal amplification (LAMP) or reverse-transcription LAMP (RT-LAMP) on a commercial membrane, without the need for complex chip fabrication or use of specialized equipment. Due to the pore size distribution, the theoretical error for digital LAMP on these membranes was analyzed, using a combination of Random Distribution Model and Multivolume Theory. A facile peel-off process was developed for effective droplet formation on the commercial track-etched polycarbonate (PCTE) membrane. Each pore functions as an individual nanoreactor for single DNA amplification. Absolute quantification of bacteria genomic DNA was realized with a dynamic range from 11 to 1.1 × 105 copies/μL. One-step digital RT-LAMP was also successfully performed on the membrane for the quantification of MS2 virus in wastewater. With the introduction of new probes, the positive pores can be easily distinguished from negative ones with 100 times difference in fluorescence intensities. Finally, the cost of a disposable membrane is less than $0.10/piece, which, to the best of our knowledge, is the most inexpensive way to perform digital LAMP. The membrane system offers opportunities for point-of-care users or common laboratories to perform digital quantification, single cell analysis, or other bioassays in an inexpensive, flexible, and simplified way.

[1]  Tza-Huei Wang,et al.  Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP). , 2015, Lab on a chip.

[2]  Luke P. Lee,et al.  Digital LAMP in a sample self-digitization (SD) chip. , 2012, Lab on a chip.

[3]  Yusi Fu,et al.  Digital polymerase chain reaction in an array of femtoliter polydimethylsiloxane microreactors. , 2012, Analytical chemistry.

[4]  J. Shuga,et al.  Single-cell multiplex gene detection and sequencing with microfluidically generated agarose emulsions. , 2011, Angewandte Chemie.

[5]  Jacques Schrenzel,et al.  Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. , 2011, FEMS immunology and medical microbiology.

[6]  C. R. Martin,et al.  Ultramicrodisk electrode ensembles prepared by incorporating carbon paste into a microporous host membrane , 1988 .

[7]  Yong Zeng,et al.  Digital PCR using micropatterned superporous absorbent array chips. , 2016, The Analyst.

[8]  T. Notomi,et al.  Loop-mediated isothermal amplification method for the rapid detection of Enterococcus faecalis in infected root canals. , 2007, Oral microbiology and immunology.

[9]  R. Ismagilov,et al.  Flow-through Capture and in Situ Amplification Can Enable Rapid Detection of a Few Single Molecules of Nucleic Acids from Several Milliliters of Solution. , 2016, Analytical chemistry.

[10]  Xingyu Lin,et al.  Asymmetric Membrane for Digital Detection of Single Bacteria in Milliliters of Complex Water Samples , 2018, ACS nano.

[11]  J. A. Quinn,et al.  Model pores of molecular dimension. The preparation and characterization of track-etched membranes. , 1972, Biophysical journal.

[12]  Xingyu Lin,et al.  A microfluidic chip capable of switching W/O droplets to vertical laminar flow for electrochemical detection of droplet contents. , 2014, Analytica chimica acta.

[13]  B. Kan,et al.  Rapid and Sensitive Salmonella Typhi Detection in Blood and Fecal Samples Using Reverse Transcription Loop-Mediated Isothermal Amplification. , 2015, Foodborne pathogens and disease.

[14]  Luke P. Lee,et al.  Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip , 2017, Science Advances.

[15]  Charles S Henry,et al.  Utilizing Paper-Based Devices for Antimicrobial-Resistant Bacteria Detection. , 2017, Angewandte Chemie.

[16]  Ying Zhu,et al.  Droplet-Based Multivolume Digital Polymerase Chain Reaction by a Surface-Assisted Multifactor Fluid Segmentation Approach. , 2017, Analytical chemistry.

[17]  Gwo-Bin Lee,et al.  A microfluidic chip capable of generating and trapping emulsion droplets for digital loop-mediated isothermal amplification analysis. , 2018, Lab on a chip.

[18]  Sunny C. Jiang,et al.  Electrochemical disinfection of toilet wastewater using wastewater electrolysis cell , 2016, Water research.

[19]  Wei Jin,et al.  Self-priming compartmentalization digital LAMP for point-of-care. , 2012, Lab on a chip.

[20]  Meng Liu,et al.  Target-Induced and Equipment-Free DNA Amplification with a Simple Paper Device. , 2016, Angewandte Chemie.

[21]  Matthew R. Lockett,et al.  Tracking the Invasion of Small Numbers of Cells in Paper-Based Assays with Quantitative PCR. , 2015, Analytical chemistry.

[22]  E. Lingohr,et al.  Enumeration of bacteriophages by double agar overlay plaque assay. , 2009, Methods in molecular biology.

[23]  Q. Fang,et al.  Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay. , 2017, Analytical chemistry.

[24]  Xingyu Lin,et al.  Ultrathin Silica Membranes with Highly Ordered and Perpendicular Nanochannels for Precise and Fast Molecular Separation. , 2015, ACS nano.

[25]  Zhi Zhu,et al.  Microwell Array Method for Rapid Generation of Uniform Agarose Droplets and Beads for Single Molecule Analysis. , 2018, Analytical chemistry.

[26]  Phillip I. Tarr,et al.  Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Common Strains of Escherichia coli , 2008, Journal of Clinical Microbiology.

[27]  A. Aryanfar,et al.  Effects of anodic potential and chloride ion on overall reactivity in electrochemical reactors designed for solar-powered wastewater treatment. , 2014, Environmental science & technology.

[28]  J. Duin Single-Stranded RNA Bacteriophages , 1988 .

[29]  Yi Hu,et al.  Absolute Quantification of H5-Subtype Avian Influenza Viruses Using Droplet Digital Loop-Mediated Isothermal Amplification. , 2017, Analytical chemistry.

[30]  Tony M. Yen,et al.  Self-Assembled Pico-Liter Droplet Microarray for Ultrasensitive Nucleic Acid Quantification. , 2015, ACS nano.

[31]  Xuezhi Ma,et al.  Capillary-Force-Assisted Clean-Stamp Transfer of Two-Dimensional Materials. , 2017, Nano letters.

[32]  Fangli Zhang,et al.  Centrifugal micro-channel array droplet generation for highly parallel digital PCR. , 2017, Lab on a chip.

[33]  Lin Qiu,et al.  A scalable self-priming fractal branching microchannel net chip for digital PCR. , 2017, Lab on a chip.

[34]  Sunny C. Jiang,et al.  Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters , 2018, Environmental science & technology.

[35]  Christopher M. Hindson,et al.  Absolute quantification by droplet digital PCR versus analog real-time PCR , 2013, Nature Methods.

[36]  Peng Xu,et al.  Cross-Interface Emulsification for Generating Size-Tunable Droplets. , 2016, Analytical chemistry.

[37]  Bing Sun,et al.  Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol. , 2013, Analytical chemistry.

[38]  Stephen R. Quake,et al.  Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria , 2006, Science.

[39]  Yasuyoshi Mori,et al.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products , 2008, Nature Protocols.

[40]  M. Baker Digital PCR hits its stride , 2012, Nature Methods.

[41]  A. Griffiths,et al.  Particle-to-PFU Ratio of Ebola Virus Influences Disease Course and Survival in Cynomolgus Macaques , 2015, Journal of Virology.

[42]  Roland Zengerle,et al.  Digital droplet PCR on disk. , 2016, Lab on a chip.

[43]  Todd Munson,et al.  Theoretical design and analysis of multivolume digital assays with wide dynamic range validated experimentally with microfluidic digital PCR. , 2011, Analytical chemistry.

[44]  Xiaojun Feng,et al.  Monte Carlo Modeling-Based Digital Loop-Mediated Isothermal Amplification on a Spiral Chip for Absolute Quantification of Nucleic Acids. , 2017, Analytical chemistry.

[45]  Anupam Singhal,et al.  Megapixel digital PCR , 2011, Nature Methods.

[46]  L. Yeo,et al.  Highly Ordered Arrays of Femtoliter Surface Droplets. , 2015, Small.

[47]  Bin Su,et al.  Polydimethysiloxane Modified Silica Nanochannel Membrane for Hydrophobicity-Based Molecular Filtration and Detection. , 2016, Analytical chemistry.