High-Resolution Functional MRI at 3 T: 3D/2D Echo-Planar Imaging with Optimized Physiological Noise Correction
暂无分享,去创建一个
Nikolaus Weiskopf | Antoine Lutti | Chloe Hutton | David L Thomas | David L. Thomas | A. Lutti | N. Weiskopf | C. Hutton
[1] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[2] Bradley G Goodyear,et al. Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection , 2004, Magnetic resonance in medicine.
[3] Ravi S. Menon. Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI , 2002, Magnetic resonance in medicine.
[4] Karl J. Friston,et al. Statistical parametric mapping , 2013 .
[5] Stephen M Smith,et al. High‐resolution FMRI at 1.5T using balanced SSFP , 2006, Magnetic resonance in medicine.
[6] Erno J. Hermans,et al. Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T , 2008, NMR in biomedicine.
[7] Robert L Barry,et al. Complex and magnitude‐only preprocessing of 2D and 3D BOLD fMRI data at 7 T , 2012, Magnetic resonance in medicine.
[8] Karl J. Friston,et al. Statistical parametric mapping , 2013 .
[9] Stephen M. Smith,et al. Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging , 2010, PloS one.
[10] Lawrence L. Wald,et al. Three dimensional echo-planar imaging at 7 Tesla , 2010, NeuroImage.
[11] R Turner,et al. Optimisation of the 3D MDEFT sequence for anatomical brain imaging: technical implications at 1.5 and 3 T , 2004, NeuroImage.
[12] Lawrence L. Wald,et al. Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters , 2005, NeuroImage.
[13] G H Glover,et al. Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.
[14] D. Hassabis,et al. Decoding Individual Episodic Memory Traces in the Human Hippocampus , 2010, Current Biology.
[15] Onur Afacan,et al. Rapid full‐brain fMRI with an accelerated multi shot 3D EPI sequence using both UNFOLD and GRAPPA , 2012, Magnetic resonance in medicine.
[16] R. Deichmann,et al. Eye-specific effects of binocular rivalry in the human lateral geniculate nucleus , 2005, Nature.
[17] Jeff H. Duyn,et al. Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal , 2007, NeuroImage.
[18] David G Norris,et al. A comparison of signal instability in 2D and 3D EPI resting‐state fMRI , 2005, NMR in Biomedicine.
[19] L. Wald,et al. 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry , 2006, Magnetic resonance in medicine.
[20] Catie Chang,et al. Effects of model-based physiological noise correction on default mode network anti-correlations and correlations , 2009, NeuroImage.
[21] S. Holland,et al. NMR relaxation times in the human brain at 3.0 tesla , 1999, Journal of magnetic resonance imaging : JMRI.
[22] Christian Schwarzbauer,et al. Dual echo EPI – The method of choice for fMRI in the presence of magnetic field inhomogeneities? , 2010, NeuroImage.
[23] Robin M Heidemann,et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.
[24] Karla L. Miller,et al. Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI , 2011, NeuroImage.
[25] Yanle Hu,et al. Three‐dimensional spiral technique for high‐resolution functional MRI , 2007, Magnetic resonance in medicine.
[26] R. Goebel,et al. Mapping the Organization of Axis of Motion Selective Features in Human Area MT Using High-Field fMRI , 2011, PloS one.
[27] Oliver Speck,et al. The impact of physiological noise correction on fMRI at 7 T , 2011, NeuroImage.
[28] D. Norris,et al. Layer‐specific BOLD activation in human V1 , 2010, Human brain mapping.
[29] W van der Zwaag,et al. Temporal SNR characteristics in segmented 3D‐EPI at 7T , 2012, Magnetic resonance in medicine.
[30] Peter A. Bandettini,et al. Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI , 2006, NeuroImage.
[31] Karl J. Friston,et al. Unified segmentation , 2005, NeuroImage.
[32] Lawrence L. Wald,et al. Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils , 2011, NeuroImage.
[33] Essa Yacoub,et al. High-field fMRI unveils orientation columns in humans , 2008, Proceedings of the National Academy of Sciences.
[34] M. Zaitsev,et al. High resolution single-shot EPI at 7T , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.
[35] Stephen C. Strother,et al. Data-driven optimization and evaluation of 2D EPI and 3D PRESTO for BOLD fMRI at 7 Tesla: I. Focal coverage , 2011, NeuroImage.
[36] G B Matson,et al. An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients. , 1994, Magnetic resonance imaging.
[37] Karl J. Friston,et al. Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.
[38] R A Knight,et al. MR imaging of human brain at 3.0 T: preliminary report on transverse relaxation rates and relation to estimated iron content. , 1999, Radiology.