Seismic Behavior of Reduced Beam Section Moment Connections to Deep Columns

An analytical study was conducted to investigate the seismic behavior of reduced beam section (RBS) moment connections to a deep wide flange column. Calibrated three-dimensional finite element models of RBS connections in perimeter special moment resisting frames with deep columns were used to perform parametric studies under inelastic monotonic and cyclic loading. The parameters in the study included: beam-to-column connection type, column section, composite floor slab, panel zone strength, and beam web slenderness. The results from the parametric study show that a composite floor slab provides restraint to the top flange of the beams, reducing the magnitude of beam top and bottom flange lateral movement in the RBS, column twist, and strength degradation due to beam instability in the RBS. The effect of beam web slenderness contributing to an increase in the lateral movement of the beam flange in the RBS and column flange is significantly reduced when a composite floor slab is present. A weaker panel zone results in higher potential for ductile fracture in the connection region. An RBS connection to a deep column is shown to have less potential for ductile fracture in the connection region than a welded unreinforced flange connection. The potential for fracture is increased in RBS connections when the column section properties are reduced, leading to larger stress and strain.

[1]  C. V. Anderson,et al.  The Federal Emergency Management Agency (FEMA) , 2002 .

[2]  Chia-Ming Uang,et al.  Cyclic Response and Design Recommendations of Reduced Beam Section Moment Connections with Deep Columns , 2002 .

[3]  Robert Tremblay,et al.  Loading rate effects and influence of floor slab on the seismic performance of RBS connections for steel moment resisting frames , 1997 .

[4]  James M. Ricles,et al.  Effect of Local Details on Ductility of Welded Moment Connections , 2001 .

[5]  Jean Lemaitre,et al.  A Course on Damage Mechanics , 1992 .

[6]  P A Seaburg,et al.  TORSIONAL ANALYSIS OF STRUCTURAL STEEL MEMBERS , 1997 .

[7]  조효남,et al.  Load & Resistance Factor Design - AISC , Manual of Steel Construction , 2nd Edition - , 1995 .

[8]  W. J. Hall,et al.  Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings , 2001 .

[9]  Sheng-Jin Chen,et al.  Ductile Steel Beam-to-Column Connections for Seismic Resistance , 1996 .

[10]  Chia-Ming Uang,et al.  Cyclic Stability Criteria for Steel Moment Connections with Reduced Beam Section , 2001 .

[11]  Michael D. Engelhardt,et al.  Experimental Evaluation of Cyclically Loaded Reduced Beam Section Moment Connections , 2002 .

[12]  J. Hancock,et al.  On the mechanisms of ductile failure in high-strength steels subjected to multi-axial stress-states , 1976 .

[13]  James M. Ricles,et al.  Development of Seismic Guidelines for Deep-Column Steel Moment Connections , 2004 .

[14]  Andrew J. Zekany,et al.  Experimental Investigation of Dogbone Moment Connections , 1998 .

[15]  Le-Wu Lu,et al.  CYCLIC TESTS OF FULL-SCALE COMPOSITE JOINT SUBASSEMBLAGES , 1989 .