Detection of shockable and non-shockable rhythms in presence of CPR artifacts by time-frequency ECG analysis

Time-frequency domain features of chest compression (CC) artefacts, non-shockable (NShR) and shockable (ShR) rhythms were investigated. The aim was to provide reliable shock advisory analysis during CC by single channel electrocardiogram (ECG) processing. Three frequency bands were suggested to enhance specific components of the CC artefacts, NShR and ShR rhythms: (i) 2–3 Hz to emphasize the similarity of the basic wave of CC Artefacts; (ii) 4–7 Hz to highlight the irregularity of the fibrillation waves in ShR; (iii) 10–20 Hz to support the presence of QRS complexes in NShR. Based on our studies in the defined frequency bands, an automatic shock-advisory system (SAS) for detection of NShR and ShR in CC-contaminated ECGs was built. SAS assessed with ECGs from a testing dataset provided Se=94.2% for ShR, Sp=87% for NShR, Sp=83.7% for asystoles.

[1]  L. Bossaert,et al.  European Resuscitation Council guidelines for resuscitation , 1998 .

[2]  Trygve Eftestøl,et al.  CPR artifact removal from human ECG using optimal multichannel filtering , 2000, IEEE Transactions on Biomedical Engineering.

[3]  Jesus Ruiz,et al.  A method to remove CPR artefacts from human ECG using only the recorded ECG. , 2008, Resuscitation.

[4]  Klaus Rheinberger,et al.  Removal of CPR Artifacts From the Ventricular Fibrillation ECG by Adaptive Regression on Lagged Reference Signals , 2008, IEEE Transactions on Biomedical Engineering.

[5]  M. Stapff [Artefacts]. , 2019, Bildgebung = Imaging.

[6]  Trygve Eftestøl,et al.  Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm , 2002, IEEE Transactions on Biomedical Engineering.

[7]  G. Perkins,et al.  European Resuscitation Council guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators. , 2005, Resuscitation.

[8]  Irena Jekova,et al.  Bench study of the accuracy of a commercial AED arrhythmia analysis algorithm in the presence of electromagnetic interferences , 2009, Physiological measurement.

[9]  Maaret Castrén,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators , 2010, Resuscitation.

[10]  Jesus Ruiz,et al.  Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts. , 2007, Resuscitation.

[11]  Trygve Eftestøl,et al.  A Least Mean-Square Filter for the Estimation of the Cardiopulmonary Resuscitation Artifact Based on the Frequency of the Compressions , 2009, IEEE Transactions on Biomedical Engineering.

[12]  Gavin D Perkins,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 4. Adult advanced life support. , 2010, Resuscitation.