Model-based tracking of the bones of the foot: A biplane fluoroscopy validation study

Measuring foot kinematics using optical motion capture is technically challenging due to the depth of the talus, small bone size, and soft tissue artifact. We present a validation of our biplane X-ray system, demonstrating its accuracy in tracking the foot bones directly. Using an experimental linear/rotary stage we imaged pairs of tali, calcanei, and first metatarsals, with embedded beads, through 30 poses. Model- and bead-based algorithms were employed for semi-automatic tracking. Translational and rotational poses were compared to the experimental stage (a reference standard) to determine registration performance. For each bone, 10 frames per pose were analyzed. Model-based: The resulting overall translational bias of the six bones was 0.058 mm with a precision of ± 0.049 mm. The overall rotational bias of the six bones was 0.42° with a precision of ± 0.41°. Bead-based: the overall translational bias was 0.037 mm with a precision of ± 0.032 mm and for rotation was 0.29° with a precision of ± 0.26°. We validated the accuracy of our system to determine the spatial position and orientation of isolated foot bones, including the talus, calcaneus, and first metatarsal over a range of quasi-static poses. Although the accuracy of dynamic motion was not assessed, use of an experimental stage establishes a reference standard.

[1]  D. B. Baier,et al.  X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. , 2010, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[2]  A. Nicol,et al.  A multi-segment kinematic model of the foot with a novel definition of forefoot motion for use in clinical gait analysis during walking. , 2007, Journal of biomechanics.

[3]  Louis E DeFrate,et al.  In Vivo Kinematics of the Tibiotalar Joint After Lateral Ankle Instability , 2009, The American journal of sports medicine.

[4]  R. Marks,et al.  Preoperative gait characterization of patients with ankle arthrosis. , 2006, Gait & posture.

[5]  G F Harris,et al.  A system for the analysis of foot and ankle kinematics during gait. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[6]  B. L. Kaptein,et al.  Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data , 2017, Bone & joint research.

[7]  Joseph J Crisco,et al.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques. , 2011, Journal of biomechanical engineering.

[8]  A Leardini,et al.  Repeatability of a multi-segment foot protocol in adult subjects. , 2011, Gait & posture.

[9]  J. P. Lewis Fast Normalized Cross-Correlation , 2010 .

[10]  William R Ledoux,et al.  Marker-based validation of a biplane fluoroscopy system for quantifying foot kinematics. , 2014, Medical engineering & physics.

[11]  Michael J Bey,et al.  Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings. , 2010, The spine journal : official journal of the North American Spine Society.

[12]  Michael J Bey,et al.  Accuracy and feasibility of dual fluoroscopy and model-based tracking to quantify in vivo hip kinematics during clinical exams. , 2014, Journal of applied biomechanics.

[13]  T. Jenkyn,et al.  Quantifying skin motion artifact error of the hindfoot and forefoot marker clusters with the optical tracking of a multi-segment foot model using single-plane fluoroscopy. , 2011, Gait & posture.

[14]  Scott Tashman,et al.  Validation of three-dimensional model-based tibio-femoral tracking during running. , 2009, Medical engineering & physics.

[15]  Scott Tashman,et al.  Journal of Orthopaedic Surgery and Research Accuracy of Biplane X-ray Imaging Combined with Model-based Tracking for Measuring In-vivo Patellofemoral Joint Motion , 2022 .

[16]  N. Zheng,et al.  Investigation of soft tissue movement during level walking: translations and rotations of skin markers. , 2008, Journal of biomechanics.

[17]  Michael J Bey,et al.  Measuring dynamic in-vivo elbow kinematics: description of technique and estimation of accuracy. , 2012, Journal of biomechanical engineering.

[18]  James D. Kang,et al.  Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement , 2011, Spine.

[19]  Cody D. Hillin,et al.  Adult-acquired flatfoot deformity and age-related differences in foot and ankle kinematics during the single-limb heel-rise test. , 2014, The Journal of orthopaedic and sports physical therapy.

[20]  Guoan Li,et al.  Non-invasive determination of coupled motion of the scapula and humerus--an in-vitro validation. , 2011, Journal of biomechanics.

[21]  B. MacWilliams,et al.  Foot kinematics and kinetics during adolescent gait. , 2003, Gait & posture.

[22]  Veerle Segers,et al.  A clinically applicable six‐segmented foot model , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  Guoan Li,et al.  Six DOF in vivo kinematics of the ankle joint complex: Application of a combined dual‐orthogonal fluoroscopic and magnetic resonance imaging technique , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  Alberto Leardini,et al.  Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: performance of a novel method during selected motor tasks , 2005, IEEE Transactions on Biomedical Engineering.

[25]  William R Ledoux,et al.  Multi-rigid image segmentation and registration for the analysis of joint motion from three-dimensional magnetic resonance imaging. , 2011, Journal of biomechanical engineering.

[26]  Scott Tashman,et al.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. , 2006, Journal of biomechanical engineering.

[27]  Andrew E Anderson,et al.  Accuracy and feasibility of high-speed dual fluoroscopy and model-based tracking to measure in vivo ankle arthrokinematics. , 2015, Gait & posture.

[28]  Dan Karlsson,et al.  The relative skin movement of the foot: a 2-D roentgen photogrammetry study. , 1998, Clinical biomechanics.

[29]  Scott Tashman,et al.  Model-based tracking of the hip: implications for novel analyses of hip pathology. , 2011, The Journal of arthroplasty.

[30]  Masahiro Shimizu,et al.  Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method , 2015, Journal of Foot and Ankle Research.

[31]  Shaobai Wang,et al.  In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics. , 2013, Medical engineering & physics.

[32]  A. Lundberg,et al.  Foot kinematics during walking measured using bone and surface mounted markers. , 2007, Journal of biomechanics.

[33]  Gregor Kuntze,et al.  Validating Dual Fluoroscopy System Capabilities for Determining In-Vivo Knee Joint Soft Tissue Deformation: A Strategy for Registration Error Management. , 2015, Journal of biomechanics.

[34]  B. Galna,et al.  Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. , 2010, Gait & posture.

[35]  Scott Tashman,et al.  The inaccuracy of surface-measured model-derived tibiofemoral kinematics. , 2012, Journal of biomechanics.

[36]  T. Gill,et al.  In vivo kinematics of the ACL during weight‐bearing knee flexion , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[37]  Taly Gilat Schmidt,et al.  Biplane fluoroscopy for hindfoot motion analysis during gait: A model-based evaluation. , 2017, Medical engineering & physics.

[38]  Harry E Rubash,et al.  In Vivo Articular Cartilage Contact Kinematics of the Knee , 2005, The American journal of sports medicine.

[39]  J J O'Connor,et al.  Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis. , 2001, Journal of biomechanics.

[40]  Thomas R Jenkyn,et al.  Foot segment kinematics during normal walking using a multisegment model of the foot and ankle complex. , 2009, Journal of biomechanical engineering.